| 1 |
pjm2 |
1.1 |
VERSION 5.00 |
| 2 |
|
|
Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX" |
| 3 |
|
|
Begin VB.Form Form1 |
| 4 |
|
|
BorderStyle = 3 'Fixed Dialog |
| 5 |
|
|
Caption = "TCP/UDP Test program" |
| 6 |
|
|
ClientHeight = 5655 |
| 7 |
|
|
ClientLeft = 45 |
| 8 |
|
|
ClientTop = 330 |
| 9 |
|
|
ClientWidth = 5670 |
| 10 |
|
|
LinkTopic = "Form1" |
| 11 |
|
|
MaxButton = 0 'False |
| 12 |
|
|
MinButton = 0 'False |
| 13 |
|
|
ScaleHeight = 5655 |
| 14 |
|
|
ScaleWidth = 5670 |
| 15 |
|
|
ShowInTaskbar = 0 'False |
| 16 |
|
|
StartUpPosition = 3 'Windows Default |
| 17 |
|
|
Begin VB.CommandButton Command3 |
| 18 |
|
|
Caption = "TCP to Filter" |
| 19 |
|
|
Height = 375 |
| 20 |
|
|
Left = 3720 |
| 21 |
|
|
TabIndex = 9 |
| 22 |
|
|
Top = 2520 |
| 23 |
|
|
Width = 1575 |
| 24 |
|
|
End |
| 25 |
|
|
Begin VB.TextBox Text4 |
| 26 |
|
|
Height = 2535 |
| 27 |
|
|
Left = 240 |
| 28 |
|
|
MultiLine = -1 'True |
| 29 |
|
|
ScrollBars = 2 'Vertical |
| 30 |
|
|
TabIndex = 8 |
| 31 |
|
|
Text = "nettest.frx":0000 |
| 32 |
|
|
Top = 3000 |
| 33 |
|
|
Width = 5055 |
| 34 |
|
|
End |
| 35 |
|
|
Begin VB.CommandButton Command2 |
| 36 |
|
|
Caption = "TCP to FilterManager" |
| 37 |
|
|
Height = 375 |
| 38 |
|
|
Left = 3360 |
| 39 |
|
|
TabIndex = 7 |
| 40 |
|
|
Top = 2040 |
| 41 |
|
|
Width = 1935 |
| 42 |
|
|
End |
| 43 |
|
|
Begin MSWinsockLib.Winsock Winsock2 |
| 44 |
|
|
Left = 4920 |
| 45 |
|
|
Top = 120 |
| 46 |
|
|
_ExtentX = 741 |
| 47 |
|
|
_ExtentY = 741 |
| 48 |
|
|
_Version = 393216 |
| 49 |
|
|
End |
| 50 |
|
|
Begin VB.TextBox Text3 |
| 51 |
|
|
Height = 285 |
| 52 |
|
|
Left = 1680 |
| 53 |
|
|
TabIndex = 5 |
| 54 |
|
|
Text = "killigrew.ukc.ac.uk" |
| 55 |
|
|
Top = 1560 |
| 56 |
|
|
Width = 2535 |
| 57 |
|
|
End |
| 58 |
|
|
Begin VB.TextBox Text2 |
| 59 |
|
|
Height = 285 |
| 60 |
|
|
Left = 1680 |
| 61 |
|
|
TabIndex = 3 |
| 62 |
|
|
Text = "4567" |
| 63 |
|
|
Top = 1920 |
| 64 |
|
|
Width = 855 |
| 65 |
|
|
End |
| 66 |
|
|
Begin VB.CommandButton Command1 |
| 67 |
|
|
Caption = "Send UDP" |
| 68 |
|
|
Height = 375 |
| 69 |
|
|
Left = 4320 |
| 70 |
|
|
TabIndex = 2 |
| 71 |
|
|
Top = 1560 |
| 72 |
|
|
Width = 975 |
| 73 |
|
|
End |
| 74 |
|
|
Begin VB.TextBox Text1 |
| 75 |
|
|
Height = 855 |
| 76 |
|
|
Left = 360 |
| 77 |
|
|
TabIndex = 0 |
| 78 |
|
|
Text = "<packet></packet>" |
| 79 |
|
|
Top = 600 |
| 80 |
|
|
Width = 4935 |
| 81 |
|
|
End |
| 82 |
|
|
Begin MSWinsockLib.Winsock Winsock1 |
| 83 |
|
|
Left = 4320 |
| 84 |
|
|
Top = 120 |
| 85 |
|
|
_ExtentX = 741 |
| 86 |
|
|
_ExtentY = 741 |
| 87 |
|
|
_Version = 393216 |
| 88 |
|
|
Protocol = 1 |
| 89 |
|
|
End |
| 90 |
|
|
Begin VB.Label Label3 |
| 91 |
|
|
Alignment = 1 'Right Justify |
| 92 |
|
|
Caption = "Destination:" |
| 93 |
|
|
Height = 255 |
| 94 |
|
|
Left = 360 |
| 95 |
|
|
TabIndex = 6 |
| 96 |
|
|
Top = 1560 |
| 97 |
|
|
Width = 1215 |
| 98 |
|
|
End |
| 99 |
|
|
Begin VB.Label Label2 |
| 100 |
|
|
Alignment = 1 'Right Justify |
| 101 |
|
|
Caption = "Port:" |
| 102 |
|
|
Height = 255 |
| 103 |
|
|
Left = 360 |
| 104 |
|
|
TabIndex = 4 |
| 105 |
|
|
Top = 1920 |
| 106 |
|
|
Width = 1215 |
| 107 |
|
|
End |
| 108 |
|
|
Begin VB.Label Label1 |
| 109 |
|
|
Caption = "Packet contents" |
| 110 |
|
|
Height = 255 |
| 111 |
|
|
Left = 360 |
| 112 |
|
|
TabIndex = 1 |
| 113 |
|
|
Top = 360 |
| 114 |
|
|
Width = 2895 |
| 115 |
|
|
End |
| 116 |
|
|
End |
| 117 |
|
|
Attribute VB_Name = "Form1" |
| 118 |
|
|
Attribute VB_GlobalNameSpace = False |
| 119 |
|
|
Attribute VB_Creatable = False |
| 120 |
|
|
Attribute VB_PredeclaredId = True |
| 121 |
|
|
Attribute VB_Exposed = False |
| 122 |
pjm2 |
1.2 |
Dim filterHostname As String |
| 123 |
pjm2 |
1.3 |
Dim filterTCPPort As Integer |
| 124 |
|
|
Dim filterUDPPort As Integer |
| 125 |
|
|
Dim fileList As String |
| 126 |
|
|
Dim lastModified As String |
| 127 |
pjm2 |
1.2 |
|
| 128 |
|
|
Dim protocolVersion As String |
| 129 |
|
|
Dim connected As Boolean |
| 130 |
pjm2 |
1.1 |
Dim responseNumber As Integer |
| 131 |
|
|
|
| 132 |
|
|
|
| 133 |
|
|
Private Sub Command1_Click() |
| 134 |
|
|
|
| 135 |
pjm2 |
1.2 |
' Use the first winsock control to send a UDP packet. |
| 136 |
pjm2 |
1.1 |
Winsock1.RemoteHost = Text3.Text |
| 137 |
|
|
Winsock1.RemotePort = Text2.Text |
| 138 |
|
|
Winsock1.SendData Text1.Text |
| 139 |
|
|
|
| 140 |
|
|
End Sub |
| 141 |
|
|
|
| 142 |
|
|
Private Sub Command2_Click() |
| 143 |
|
|
|
| 144 |
pjm2 |
1.3 |
' establish a TCP connection to a filtermanager |
| 145 |
pjm2 |
1.1 |
Winsock2.Close |
| 146 |
|
|
Winsock2.Connect Text3.Text, Text2.Text |
| 147 |
|
|
|
| 148 |
|
|
End Sub |
| 149 |
|
|
|
| 150 |
|
|
Private Sub Command3_Click() |
| 151 |
pjm2 |
1.3 |
' establish a TCP connection to a filter |
| 152 |
|
|
Winsock2.Close |
| 153 |
|
|
Winsock2.Connect filterHostname, filterTCPPort |
| 154 |
pjm2 |
1.1 |
End Sub |
| 155 |
|
|
|
| 156 |
pjm2 |
1.2 |
Private Sub Form_Load() |
| 157 |
|
|
protocolVersion = "1.1" |
| 158 |
|
|
End Sub |
| 159 |
|
|
|
| 160 |
pjm2 |
1.1 |
Private Sub Winsock2_Connect() |
| 161 |
|
|
|
| 162 |
|
|
responseNumber = 0 |
| 163 |
|
|
|
| 164 |
pjm2 |
1.3 |
' Send something as soon as we connect to the server. |
| 165 |
|
|
If connected = False Then |
| 166 |
|
|
' contact the FilterManager |
| 167 |
|
|
Winsock2.SendData "STARTCONFIG" & vbCrLf |
| 168 |
|
|
Else |
| 169 |
|
|
' Contact the Filter |
| 170 |
|
|
Winsock2.SendData "HEARTBEAT" & vbCrLf |
| 171 |
|
|
End If |
| 172 |
pjm2 |
1.1 |
|
| 173 |
|
|
End Sub |
| 174 |
|
|
|
| 175 |
|
|
Private Sub Winsock2_DataArrival(ByVal bytesTotal As Long) |
| 176 |
|
|
|
| 177 |
|
|
responseNumber = responseNumber + 1 |
| 178 |
|
|
|
| 179 |
|
|
' Get the line from the server. |
| 180 |
|
|
Winsock2.GetData response, vbString, bytesTotal |
| 181 |
|
|
|
| 182 |
|
|
' Remove linefeeds and returns from the line. |
| 183 |
|
|
response = Replace(response, Chr(13), "") |
| 184 |
|
|
response = Replace(response, Chr(10), "") |
| 185 |
|
|
Text4.Text = Text4.Text & vbCrLf & response |
| 186 |
|
|
|
| 187 |
pjm2 |
1.2 |
If connected = False Then |
| 188 |
|
|
' Perform TCP configuration (1.1) |
| 189 |
|
|
On Error GoTo configError |
| 190 |
|
|
Select Case responseNumber |
| 191 |
|
|
Case 1: |
| 192 |
|
|
If Not response = "OK" Then GoTo configError |
| 193 |
|
|
Winsock2.SendData "LASTMODIFIED" & vbCrLf |
| 194 |
|
|
Case 2: |
| 195 |
|
|
If response = "ERROR" Then GoTo configError |
| 196 |
pjm2 |
1.3 |
lastModified = response |
| 197 |
pjm2 |
1.2 |
Winsock2.SendData "FILELIST" & vbCrLf |
| 198 |
|
|
Case 3: |
| 199 |
|
|
If response = "ERROR" Then GoTo configError |
| 200 |
pjm2 |
1.3 |
fileList = response |
| 201 |
pjm2 |
1.2 |
Winsock2.SendData "UDPUpdateTime" & vbCrLf |
| 202 |
|
|
Case 4: |
| 203 |
|
|
If response = "ERROR" Then GoTo configError |
| 204 |
|
|
Winsock2.SendData "TCPUpdateTime" & vbCrLf |
| 205 |
|
|
Case 5: |
| 206 |
|
|
If response = "ERROR" Then GoTo configError |
| 207 |
|
|
Winsock2.SendData "ENDCONFIG" & vbCrLf |
| 208 |
|
|
Case 6: |
| 209 |
|
|
If Not response = "OK" Then GoTo configError |
| 210 |
|
|
Winsock2.SendData "FILTER" & vbCrLf |
| 211 |
|
|
Case 7: |
| 212 |
|
|
'we got a filter list here. |
| 213 |
|
|
readTo = 0 |
| 214 |
|
|
' get hostname |
| 215 |
|
|
readTo = InStr(1, response, ";", vbBinaryCompare) |
| 216 |
|
|
filterHostname = Mid(response, 1, readTo - 1) |
| 217 |
|
|
response = Mid(response, readTo + 1, Len(response)) |
| 218 |
|
|
' get UDP Port number |
| 219 |
|
|
readTo = InStr(1, response, ";") |
| 220 |
|
|
filterUDPPort = Mid(response, 1, readTo - 1) |
| 221 |
|
|
response = Mid(response, readTo + 1, Len(response)) |
| 222 |
|
|
' get TCP Port number |
| 223 |
|
|
filterTCPPort = response |
| 224 |
|
|
Winsock2.SendData "END" & vbCrLf |
| 225 |
|
|
Case 8: |
| 226 |
|
|
If Not response = "OK" Then GoTo configError |
| 227 |
|
|
connected = True |
| 228 |
|
|
responseNumber = 0 |
| 229 |
|
|
Winsock2.Close |
| 230 |
|
|
Text4.Text = Text4.Text & vbCrLf & " <closed>" |
| 231 |
|
|
x = MsgBox("got config okay") |
| 232 |
|
|
End Select |
| 233 |
|
|
Else |
| 234 |
|
|
' Perform a heartbeat (1.1) |
| 235 |
|
|
On Error GoTo heartbeatError |
| 236 |
|
|
Select Case responseNumber |
| 237 |
|
|
Case 1: |
| 238 |
pjm2 |
1.3 |
If Not response = "OK" Then GoTo heartbeatError |
| 239 |
|
|
Winsock2.SendData "CONFIG" & vbCrLf |
| 240 |
pjm2 |
1.2 |
Case 2: |
| 241 |
pjm2 |
1.3 |
If Not response = "OK" Then GoTo heartbeatError |
| 242 |
|
|
Winsock2.SendData fileList & vbCrLf |
| 243 |
pjm2 |
1.2 |
Case 3: |
| 244 |
pjm2 |
1.3 |
If Not response = "OK" Then GoTo heartbeatError |
| 245 |
|
|
Winsock2.SendData lastModified & vbCrLf |
| 246 |
pjm2 |
1.2 |
Case 4: |
| 247 |
pjm2 |
1.3 |
If Not response = "OK" Then GoTo heartbeatError |
| 248 |
|
|
Winsock2.SendData "ENDHEARTBEAT" & vbCrLf |
| 249 |
pjm2 |
1.2 |
Case 5: |
| 250 |
pjm2 |
1.3 |
If Not response = "OK" Then GoTo heartbeatError |
| 251 |
|
|
Winsock2.Close |
| 252 |
|
|
x = MsgBox("heartbeat sent okay.") |
| 253 |
pjm2 |
1.2 |
End Select |
| 254 |
|
|
|
| 255 |
|
|
End If |
| 256 |
|
|
|
| 257 |
|
|
|
| 258 |
|
|
Exit Sub |
| 259 |
|
|
|
| 260 |
|
|
configError: |
| 261 |
|
|
x = MsgBox("error doing configuration") |
| 262 |
|
|
heartbeatError: |
| 263 |
pjm2 |
1.1 |
|
| 264 |
|
|
End Sub |