ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/experimental/host/vb_net_test/nettest.frm
(Generate patch)

Comparing experimental/host/vb_net_test/nettest.frm (file contents):
Revision 1.10 by pjm2, Fri Feb 23 11:42:06 2001 UTC vs.
Revision 1.23 by pjm2, Mon Feb 26 09:54:25 2001 UTC

# Line 1 | Line 1
1   VERSION 5.00
2   Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX"
3 + Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0"; "SysTray.ocx"
4   Begin VB.Form Form1
5 <   BorderStyle     =   4  'Fixed ToolWindow
5 >   BorderStyle     =   3  'Fixed Dialog
6     Caption         =   "i-scream Winhost"
7     ClientHeight    =   5655
8     ClientLeft      =   45
9 <   ClientTop       =   285
10 <   ClientWidth     =   5670
9 >   ClientTop       =   330
10 >   ClientWidth     =   4710
11 >   Icon            =   "nettest.frx":0000
12     LinkTopic       =   "Form1"
13     MaxButton       =   0   'False
14     MinButton       =   0   'False
15     ScaleHeight     =   5655
16 <   ScaleWidth      =   5670
16 >   ScaleWidth      =   4710
17     ShowInTaskbar   =   0   'False
18     StartUpPosition =   3  'Windows Default
19 +   Begin VB.CommandButton Hide
20 +      Caption         =   "Hide Window"
21 +      Height          =   375
22 +      Left            =   3120
23 +      TabIndex        =   7
24 +      Top             =   840
25 +      Width           =   1455
26 +   End
27 +   Begin SysTray.SystemTray SystemTray
28 +      Left            =   2160
29 +      Top             =   1800
30 +      _ExtentX        =   847
31 +      _ExtentY        =   847
32 +      SysTrayText     =   "i-scream Winhost"
33 +      IconFile        =   0
34 +   End
35     Begin VB.Timer Timer1
36 <      Left            =   4200
37 <      Top             =   1200
36 >      Left            =   2760
37 >      Top             =   1800
38     End
39     Begin VB.TextBox Text4
40        Height          =   1575
# Line 24 | Line 42 | Begin VB.Form Form1
42        MultiLine       =   -1  'True
43        ScrollBars      =   2  'Vertical
44        TabIndex        =   1
45 <      Text            =   "nettest.frx":0000
45 >      Text            =   "nettest.frx":0742
46        Top             =   3000
47 <      Width           =   5055
47 >      Width           =   3975
48     End
49     Begin VB.CommandButton Reconfigure
50        Caption         =   "Reconfigure with FilterManager"
51 <      Height          =   495
51 >      Height          =   375
52        Left            =   120
53        TabIndex        =   0
54 <      Top             =   120
54 >      Top             =   840
55        Width           =   2895
56     End
57     Begin MSWinsockLib.Winsock TCPSock
58 <      Left            =   5160
59 <      Top             =   1200
58 >      Left            =   3720
59 >      Top             =   1800
60        _ExtentX        =   741
61        _ExtentY        =   741
62        _Version        =   393216
63     End
64     Begin MSWinsockLib.Winsock UDPSock
65 <      Left            =   4680
66 <      Top             =   1200
65 >      Left            =   3240
66 >      Top             =   1800
67        _ExtentX        =   741
68        _ExtentY        =   741
69        _Version        =   393216
70        Protocol        =   1
71     End
72 +   Begin VB.Label Label5
73 +      Caption         =   "b e t a"
74 +      BeginProperty Font
75 +         Name            =   "MS Sans Serif"
76 +         Size            =   24
77 +         Charset         =   0
78 +         Weight          =   700
79 +         Underline       =   0   'False
80 +         Italic          =   0   'False
81 +         Strikethrough   =   0   'False
82 +      EndProperty
83 +      Height          =   615
84 +      Left            =   240
85 +      TabIndex        =   8
86 +      Top             =   120
87 +      Width           =   1815
88 +   End
89     Begin VB.Label Label2
90        Alignment       =   1  'Right Justify
91        Caption         =   "Next heartbeat:"
92        Height          =   255
93 <      Left            =   3360
93 >      Left            =   2400
94        TabIndex        =   6
95        Top             =   480
96        Width           =   1455
# Line 64 | Line 99 | Begin VB.Form Form1
99        Alignment       =   1  'Right Justify
100        Caption         =   "Next UDP packet:"
101        Height          =   255
102 <      Left            =   3360
102 >      Left            =   2400
103        TabIndex        =   5
104        Top             =   120
105        Width           =   1455
# Line 73 | Line 108 | Begin VB.Form Form1
108        BorderStyle     =   1  'Fixed Single
109        Caption         =   "0"
110        Height          =   255
111 <      Left            =   4920
111 >      Left            =   3960
112        TabIndex        =   4
113        Top             =   480
114        Width           =   615
# Line 82 | Line 117 | Begin VB.Form Form1
117        BorderStyle     =   1  'Fixed Single
118        Caption         =   "0"
119        Height          =   255
120 <      Left            =   4920
120 >      Left            =   3960
121        TabIndex        =   3
122        Top             =   120
123        Width           =   615
124     End
125     Begin VB.Label Status
126 +      Alignment       =   2  'Center
127        Caption         =   "Status:"
128        Height          =   255
129 <      Left            =   120
129 >      Left            =   0
130        TabIndex        =   2
131 <      Top             =   840
132 <      Width           =   5415
131 >      Top             =   1320
132 >      Width           =   4695
133     End
134   End
135   Attribute VB_Name = "Form1"
# Line 101 | Line 137 | Attribute VB_GlobalNameSpace = False
137   Attribute VB_Creatable = False
138   Attribute VB_PredeclaredId = True
139   Attribute VB_Exposed = False
140 + ' For the system tray bits
141   Private Declare Function GetPrivateProfileString Lib "kernel32" Alias "GetPrivateProfileStringA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal lpDefault As String, ByVal lpReturnedString As String, ByVal nSize As Long, ByVal lpFileName As String) As Long
142   Private Declare Function GetPrivateProfileInt Lib "kernel32" Alias "GetPrivateProfileIntA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal nDefault As Long, ByVal lpFileName As String) As Long
143  
144   Dim filterManagerHostname As String
145 < Dim filterManagerTCPPort As Integer
145 > Dim filterManagerTCPPort As Long
146  
147 + Dim seqNo As Long
148 + Dim machineName As String
149 +
150   Dim filterHostname As String
151   Dim filterTCPPort As Integer
152   Dim filterUDPPort As Integer
# Line 118 | Line 158 | Dim TCPUpdateTime As Integer
158  
159   Dim protocolVersion As String
160   Dim connected As Boolean
121 Dim responseNumber As Integer
161  
162 + Dim CUpTime As New CUpTime
163  
164 < Private Sub Command1_Click()
164 > Dim responseNumber As Integer
165  
126    ' build the contents of the XML packet.
127    xml = "<packet></packet>"
128
129    ' Use the first winsock control to send a UDP packet.
130    UDPSock.RemoteHost = filterHostname
131    UDPSock.RemotePort = filterUDPPort
132    UDPSock.SendData xml
133    Status.Caption = "i-scream Winhost " & protocolVersion & " - UDP packet sent."
134
135 End Sub
136
137
138 Private Sub Command3_Click()
139    ' establish a TCP connection to a filter
140    TCPSock.Close
141    TCPSock.Connect filterHostname, filterTCPPort
142 End Sub
143
166   Private Sub Form_Load()
167 +    
168 +    If App.PrevInstance Then
169 +        x = MsgBox("There is already an i-scream Winhost running on this machine.", 48, "i-scream host already running")
170 +    End If
171 +    
172      protocolVersion = "1.1"
173 <      
173 >    
174      Status.Caption = "Loading"
175      Form1.Caption = "i-scream Winhost " & protocolVersion
176      
177 +    Form1.Show
178 +    
179 +    CUpTime.Init
180 +    
181 +    If CUpTime.isWin9x Then
182 +        x = MsgBox("Sorry, the i-scream host can only be used to monitor servers (i.e. not Win9x)", 48, "Not a server.")
183 +        End
184 +    End If
185 +    
186      ''''TEMP
187 <    filterManagerHostname = "killigrew.ukc.ac.uk"
188 <    filterManagerTCPPort = 4567
189 <    Reconfigure_Click
154 <    Exit Sub
155 <    ''' ENDTEMP
187 >    'filterManagerHostname = "killigrew.ukc.ac.uk"
188 >    'filterManagerTCPPort = 4567
189 >    ''''' END TEMP
190      
191 +    'GoTo skip
192      On Error GoTo iniError
193      Dim buf As String * 256
194      Dim length As Long
195 <    length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "<no value>", buf, Len(buf), App.Path & "winhost.ini")
195 >    length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "<no value>", buf, Len(buf), App.Path & "/winhost.ini")
196      filterManagerHostname = Left$(buf, length)
197 <    length = GetPrivateProfileString("i-scream Winhost", "FilterManagerPort", "<no value>", buf, Len(buf), App.Path & "winhost.ini")
198 <    filterManagerTCPPort = Left$(buf, length)
197 >    length = GetPrivateProfileInt("i-scream Winhost", "FilterManagerPort", 0, App.Path & "/winhost.ini")
198 >    filterManagerTCPPort = length
199 >    On Error GoTo 0
200 > skip:
201 >
202 >    Status.Caption = "Connecting to Filter Manager " & filterManagerHostname & ":" & filterManagerTCPPort
203 >    Reconfigure_Click
204      
205 <    Status.Caption = "Connecting to Filter Manager"
205 >    SystemTray.Icon = Val(Form1.Icon)
206 >    SystemTray.Action = 0
207      
208 +    
209      Exit Sub
210      
211   iniError:
212 <    x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file.  Please correct these and try again.", 48, "Configuration not found")
212 >    x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file.  Please correct these and try again.  " & Err.Description, 48, "Configuration not found")
213      End
214      
215   End Sub
216  
217   Private Sub Form_QueryUnload(Cancel As Integer, UnloadMode As Integer)
218 <    x = MsgBox("Are you sure you want to shut down the Winhost?", vbYesNo, "i-scream Winhost")
218 >    x = MsgBox("Are you sure you want to shut down the Winhost?  This will stop your computer sending information to the i-scream Central Monitoring System.", vbYesNo, "i-scream Winhost")
219      If x = 7 Then
220          Cancel = True
221 +    Else
222 +        SystemTray.Action = 2
223      End If
224  
225   End Sub
226  
227 + Private Sub Hide_Click()
228 +    Form1.Visible = False
229 +    SystemTray.Icon = Val(Form1.Icon)
230 + End Sub
231 +
232   Private Sub Reconfigure_Click()
233      ' establish a TCP connection to a filtermanager
234      connected = False
# Line 187 | Line 236 | Private Sub Reconfigure_Click()
236      TCPSock.Connect filterManagerHostname, filterManagerTCPPort
237   End Sub
238  
239 +
240 +
241 + Private Sub SystemTray_MouseDblClk(ByVal Button As Integer)
242 +
243 +    Form1.Visible = True
244 +    Form1.SetFocus
245 +    
246 +
247 + End Sub
248 +
249   Private Sub TCPSock_Connect()
250      
251      responseNumber = 0
# Line 308 | Line 367 | Private Sub Timer1_Timer()
367      Status.Caption = ""
368      
369      If Label3.Caption < 1 Then
370 <        ' build the contents of the XML packet.
371 <        xml = "<packet></packet>"
370 >        
371 >        ' prepare the contents of the XML packet.
372 >        seqNo = seqNo + 1
373 >        machineName = TCPSock.LocalHostName
374 >        LocalIP = TCPSock.LocalIP
375 >        packetDate = Date2Num()
376 >        
377 >        
378 >        Dim verinfo As OSVERSIONINFO
379 >        verinfo.dwOSVersionInfoSize = Len(verinfo)
380 >        ret% = GetVersionEx(verinfo)
381 >        If ret% = 0 Then
382 >            MsgBox "Error getting Windows version Information"
383 >            End
384 >        End If
385 >          
386 >        osName = GetVersion()
387 >        osVersionMajor = verinfo.dwMajorVersion
388 >        osVersionMinor = verinfo.dwMinorVersion
389 >        osBuild = verinfo.dwBuildNumber
390 >        
391 >        Dim sysinfo As SYSTEM_INFO
392 >        GetSystemInfo sysinfo
393 >        Select Case sysinfo.dwProcessorType
394 >            Case PROCESSOR_INTEL_386
395 >                processorType = "Intel 386"
396 >            Case PROCESSOR_INTEL_486
397 >                processorType = "Intel 486"
398 >            Case PROCESSOR_INTEL_PENTIUM
399 >                processorType = "Intel Pentium variant"
400 >            Case PROCESSOR_MIPS_R4000
401 >                processorType = "MIPS R4000"
402 >            Case PROCESSOR_ALPHA_21064
403 >                processorType = "DEC Alpha 21064"
404 >            Case Else
405 >                processorType = "(unknown)"
406 >        End Select
407 >        
408 >        Dim memsts As MEMORYSTATUS
409 >        Dim memory&
410 >        GlobalMemoryStatus memsts
411 >        memory& = memsts.dwTotalPhys
412 >        memTotal = memory& \ 1024
413 >        memory& = memsts.dwAvailPhys
414 >        memFree = memory& \ 1024
415 >        memory& = memsts.dwTotalVirtual
416 >        swapTotal = memory& \ 1024
417 >        memory& = memsts.dwAvailVirtual
418 >        swapFree = memory& \ 1024
419 >        
420 >        uptime = GetTickCount \ 1000
421 >        
422 >        CUpTime.Capture
423 >        cpu_time = CUpTime.CPUTime
424 >        percent_idle = CUpTime.PercentIdle
425 >        
426 >        ' build the contents of the XML packet
427 >        xml = "<packet seq_no=""" & seqNo & """ machine_name=""" & machineName & """ date=""" & packetDate & """ type=""data"" ip=""" & LocalIP & """>" & _
428 >              "<os>" & _
429 >                "<name>" & osName & "</name>" & _
430 >                "<version>" & osVersionMajor & "</version>" & _
431 >                "<release>" & osBuild & "</release>" & _
432 >                "<platform>" & osName & "</platform>" & _
433 >                "<minor_version>" & osVersionMinor & "</minor_version>" & _
434 >                "<processor>" & processorType & "</processor>" & _
435 >                "<uptime>" & uptime & "</uptime>" & _
436 >              "</os>" & _
437 >              "<cpu><idle>" & percent_idle & "</idle><user>" & cpu_time & "</user></cpu>" & _
438 >              "<memory><total>" & memTotal & "</total><free>" & memFree & "</free></memory>" & _
439 >              "<swap><total>" & swapTotal & "</total><free>" & swapFree & "</free></swap>" & _
440 >              "</packet>"
441 >        Text4.Text = Text4.Text + xml
442  
443          ' Use the first winsock control to send a UDP packet.
444          UDPSock.RemoteHost = filterHostname
# Line 327 | Line 456 | Private Sub Timer1_Timer()
456      End If
457  
458   End Sub
459 +
460 + Function Date2Num() As Long
461 +    Dim x As Long
462 +    x = DateDiff("s", "1-1-1970", Now)
463 +    Date2Num = x
464 + End Function

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines