1 |
VERSION 5.00 |
2 |
Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX" |
3 |
Begin VB.Form Form1 |
4 |
BorderStyle = 3 'Fixed Dialog |
5 |
Caption = "TCP/UDP Test program" |
6 |
ClientHeight = 5655 |
7 |
ClientLeft = 45 |
8 |
ClientTop = 330 |
9 |
ClientWidth = 5670 |
10 |
LinkTopic = "Form1" |
11 |
MaxButton = 0 'False |
12 |
MinButton = 0 'False |
13 |
ScaleHeight = 5655 |
14 |
ScaleWidth = 5670 |
15 |
ShowInTaskbar = 0 'False |
16 |
StartUpPosition = 3 'Windows Default |
17 |
Begin VB.CommandButton Command3 |
18 |
Caption = "TCP to Filter" |
19 |
Height = 375 |
20 |
Left = 3720 |
21 |
TabIndex = 9 |
22 |
Top = 2520 |
23 |
Width = 1575 |
24 |
End |
25 |
Begin VB.TextBox Text4 |
26 |
Height = 2535 |
27 |
Left = 240 |
28 |
MultiLine = -1 'True |
29 |
ScrollBars = 2 'Vertical |
30 |
TabIndex = 8 |
31 |
Text = "nettest.frx":0000 |
32 |
Top = 3000 |
33 |
Width = 5055 |
34 |
End |
35 |
Begin VB.CommandButton Command2 |
36 |
Caption = "TCP to FilterManager" |
37 |
Height = 375 |
38 |
Left = 3360 |
39 |
TabIndex = 7 |
40 |
Top = 2040 |
41 |
Width = 1935 |
42 |
End |
43 |
Begin MSWinsockLib.Winsock Winsock2 |
44 |
Left = 4920 |
45 |
Top = 120 |
46 |
_ExtentX = 741 |
47 |
_ExtentY = 741 |
48 |
_Version = 393216 |
49 |
End |
50 |
Begin VB.TextBox Text3 |
51 |
Height = 285 |
52 |
Left = 1680 |
53 |
TabIndex = 5 |
54 |
Text = "killigrew.ukc.ac.uk" |
55 |
Top = 1560 |
56 |
Width = 2535 |
57 |
End |
58 |
Begin VB.TextBox Text2 |
59 |
Height = 285 |
60 |
Left = 1680 |
61 |
TabIndex = 3 |
62 |
Text = "4567" |
63 |
Top = 1920 |
64 |
Width = 855 |
65 |
End |
66 |
Begin VB.CommandButton Command1 |
67 |
Caption = "Send UDP" |
68 |
Height = 375 |
69 |
Left = 4320 |
70 |
TabIndex = 2 |
71 |
Top = 1560 |
72 |
Width = 975 |
73 |
End |
74 |
Begin VB.TextBox Text1 |
75 |
Height = 855 |
76 |
Left = 360 |
77 |
TabIndex = 0 |
78 |
Text = "<packet></packet>" |
79 |
Top = 600 |
80 |
Width = 4935 |
81 |
End |
82 |
Begin MSWinsockLib.Winsock Winsock1 |
83 |
Left = 4320 |
84 |
Top = 120 |
85 |
_ExtentX = 741 |
86 |
_ExtentY = 741 |
87 |
_Version = 393216 |
88 |
Protocol = 1 |
89 |
End |
90 |
Begin VB.Label Label3 |
91 |
Alignment = 1 'Right Justify |
92 |
Caption = "Destination:" |
93 |
Height = 255 |
94 |
Left = 360 |
95 |
TabIndex = 6 |
96 |
Top = 1560 |
97 |
Width = 1215 |
98 |
End |
99 |
Begin VB.Label Label2 |
100 |
Alignment = 1 'Right Justify |
101 |
Caption = "Port:" |
102 |
Height = 255 |
103 |
Left = 360 |
104 |
TabIndex = 4 |
105 |
Top = 1920 |
106 |
Width = 1215 |
107 |
End |
108 |
Begin VB.Label Label1 |
109 |
Caption = "Packet contents" |
110 |
Height = 255 |
111 |
Left = 360 |
112 |
TabIndex = 1 |
113 |
Top = 360 |
114 |
Width = 2895 |
115 |
End |
116 |
End |
117 |
Attribute VB_Name = "Form1" |
118 |
Attribute VB_GlobalNameSpace = False |
119 |
Attribute VB_Creatable = False |
120 |
Attribute VB_PredeclaredId = True |
121 |
Attribute VB_Exposed = False |
122 |
Dim filterHostname As String |
123 |
Dim filterTCPPort As Integer |
124 |
Dim filterUDPPort As Integer |
125 |
Dim fileList As String |
126 |
Dim lastModified As String |
127 |
|
128 |
Dim protocolVersion As String |
129 |
Dim connected As Boolean |
130 |
Dim responseNumber As Integer |
131 |
|
132 |
|
133 |
Private Sub Command1_Click() |
134 |
|
135 |
' Use the first winsock control to send a UDP packet. |
136 |
Winsock1.RemoteHost = Text3.Text |
137 |
Winsock1.RemotePort = Text2.Text |
138 |
Winsock1.SendData Text1.Text |
139 |
|
140 |
End Sub |
141 |
|
142 |
Private Sub Command2_Click() |
143 |
|
144 |
' establish a TCP connection to a filtermanager |
145 |
Winsock2.Close |
146 |
Winsock2.Connect Text3.Text, Text2.Text |
147 |
|
148 |
End Sub |
149 |
|
150 |
Private Sub Command3_Click() |
151 |
' establish a TCP connection to a filter |
152 |
Winsock2.Close |
153 |
Winsock2.Connect filterHostname, filterTCPPort |
154 |
End Sub |
155 |
|
156 |
Private Sub Form_Load() |
157 |
protocolVersion = "1.1" |
158 |
End Sub |
159 |
|
160 |
Private Sub Winsock2_Connect() |
161 |
|
162 |
responseNumber = 0 |
163 |
|
164 |
' Send something as soon as we connect to the server. |
165 |
If connected = False Then |
166 |
' contact the FilterManager |
167 |
Winsock2.SendData "STARTCONFIG" & vbCrLf |
168 |
Else |
169 |
' Contact the Filter |
170 |
Winsock2.SendData "HEARTBEAT" & vbCrLf |
171 |
End If |
172 |
|
173 |
End Sub |
174 |
|
175 |
Private Sub Winsock2_DataArrival(ByVal bytesTotal As Long) |
176 |
|
177 |
responseNumber = responseNumber + 1 |
178 |
|
179 |
' Get the line from the server. |
180 |
Winsock2.GetData response, vbString, bytesTotal |
181 |
|
182 |
' Remove linefeeds and returns from the line. |
183 |
response = Replace(response, Chr(13), "") |
184 |
response = Replace(response, Chr(10), "") |
185 |
Text4.Text = Text4.Text & vbCrLf & response |
186 |
|
187 |
If connected = False Then |
188 |
' Perform TCP configuration (1.1) |
189 |
On Error GoTo configError |
190 |
Select Case responseNumber |
191 |
Case 1: |
192 |
If Not response = "OK" Then GoTo configError |
193 |
Winsock2.SendData "LASTMODIFIED" & vbCrLf |
194 |
Case 2: |
195 |
If response = "ERROR" Then GoTo configError |
196 |
lastModified = response |
197 |
Winsock2.SendData "FILELIST" & vbCrLf |
198 |
Case 3: |
199 |
If response = "ERROR" Then GoTo configError |
200 |
fileList = response |
201 |
Winsock2.SendData "UDPUpdateTime" & vbCrLf |
202 |
Case 4: |
203 |
If response = "ERROR" Then GoTo configError |
204 |
Winsock2.SendData "TCPUpdateTime" & vbCrLf |
205 |
Case 5: |
206 |
If response = "ERROR" Then GoTo configError |
207 |
Winsock2.SendData "ENDCONFIG" & vbCrLf |
208 |
Case 6: |
209 |
If Not response = "OK" Then GoTo configError |
210 |
Winsock2.SendData "FILTER" & vbCrLf |
211 |
Case 7: |
212 |
'we got a filter list here. |
213 |
readTo = 0 |
214 |
' get hostname |
215 |
readTo = InStr(1, response, ";", vbBinaryCompare) |
216 |
filterHostname = Mid(response, 1, readTo - 1) |
217 |
response = Mid(response, readTo + 1, Len(response)) |
218 |
' get UDP Port number |
219 |
readTo = InStr(1, response, ";") |
220 |
filterUDPPort = Mid(response, 1, readTo - 1) |
221 |
response = Mid(response, readTo + 1, Len(response)) |
222 |
' get TCP Port number |
223 |
filterTCPPort = response |
224 |
Winsock2.SendData "END" & vbCrLf |
225 |
Case 8: |
226 |
If Not response = "OK" Then GoTo configError |
227 |
connected = True |
228 |
responseNumber = 0 |
229 |
Winsock2.Close |
230 |
Text4.Text = Text4.Text & vbCrLf & " <closed>" |
231 |
x = MsgBox("got config okay") |
232 |
End Select |
233 |
Else |
234 |
' Perform a heartbeat (1.1) |
235 |
On Error GoTo heartbeatError |
236 |
Select Case responseNumber |
237 |
Case 1: |
238 |
If Not response = "OK" Then GoTo heartbeatError |
239 |
Winsock2.SendData "CONFIG" & vbCrLf |
240 |
Case 2: |
241 |
If Not response = "OK" Then GoTo heartbeatError |
242 |
Winsock2.SendData fileList & vbCrLf |
243 |
Case 3: |
244 |
If Not response = "OK" Then GoTo heartbeatError |
245 |
Winsock2.SendData lastModified & vbCrLf |
246 |
Case 4: |
247 |
If Not response = "OK" Then GoTo heartbeatError |
248 |
Winsock2.SendData "ENDHEARTBEAT" & vbCrLf |
249 |
Case 5: |
250 |
If Not response = "OK" Then GoTo heartbeatError |
251 |
Winsock2.Close |
252 |
x = MsgBox("heartbeat sent okay.") |
253 |
End Select |
254 |
|
255 |
End If |
256 |
|
257 |
|
258 |
Exit Sub |
259 |
|
260 |
configError: |
261 |
x = MsgBox("error doing configuration") |
262 |
heartbeatError: |
263 |
|
264 |
End Sub |