ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/experimental/host/vb_net_test/nettest.frm
Revision: 1.3
Committed: Fri Feb 23 10:07:55 2001 UTC (23 years, 9 months ago) by pjm2
Branch: MAIN
Changes since 1.2: +29 -17 lines
Log Message:
Implemented version 1.1 of the heartbeat protocol.

File Contents

# Content
1 VERSION 5.00
2 Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX"
3 Begin VB.Form Form1
4 BorderStyle = 3 'Fixed Dialog
5 Caption = "TCP/UDP Test program"
6 ClientHeight = 5655
7 ClientLeft = 45
8 ClientTop = 330
9 ClientWidth = 5670
10 LinkTopic = "Form1"
11 MaxButton = 0 'False
12 MinButton = 0 'False
13 ScaleHeight = 5655
14 ScaleWidth = 5670
15 ShowInTaskbar = 0 'False
16 StartUpPosition = 3 'Windows Default
17 Begin VB.CommandButton Command3
18 Caption = "TCP to Filter"
19 Height = 375
20 Left = 3720
21 TabIndex = 9
22 Top = 2520
23 Width = 1575
24 End
25 Begin VB.TextBox Text4
26 Height = 2535
27 Left = 240
28 MultiLine = -1 'True
29 ScrollBars = 2 'Vertical
30 TabIndex = 8
31 Text = "nettest.frx":0000
32 Top = 3000
33 Width = 5055
34 End
35 Begin VB.CommandButton Command2
36 Caption = "TCP to FilterManager"
37 Height = 375
38 Left = 3360
39 TabIndex = 7
40 Top = 2040
41 Width = 1935
42 End
43 Begin MSWinsockLib.Winsock Winsock2
44 Left = 4920
45 Top = 120
46 _ExtentX = 741
47 _ExtentY = 741
48 _Version = 393216
49 End
50 Begin VB.TextBox Text3
51 Height = 285
52 Left = 1680
53 TabIndex = 5
54 Text = "killigrew.ukc.ac.uk"
55 Top = 1560
56 Width = 2535
57 End
58 Begin VB.TextBox Text2
59 Height = 285
60 Left = 1680
61 TabIndex = 3
62 Text = "4567"
63 Top = 1920
64 Width = 855
65 End
66 Begin VB.CommandButton Command1
67 Caption = "Send UDP"
68 Height = 375
69 Left = 4320
70 TabIndex = 2
71 Top = 1560
72 Width = 975
73 End
74 Begin VB.TextBox Text1
75 Height = 855
76 Left = 360
77 TabIndex = 0
78 Text = "<packet></packet>"
79 Top = 600
80 Width = 4935
81 End
82 Begin MSWinsockLib.Winsock Winsock1
83 Left = 4320
84 Top = 120
85 _ExtentX = 741
86 _ExtentY = 741
87 _Version = 393216
88 Protocol = 1
89 End
90 Begin VB.Label Label3
91 Alignment = 1 'Right Justify
92 Caption = "Destination:"
93 Height = 255
94 Left = 360
95 TabIndex = 6
96 Top = 1560
97 Width = 1215
98 End
99 Begin VB.Label Label2
100 Alignment = 1 'Right Justify
101 Caption = "Port:"
102 Height = 255
103 Left = 360
104 TabIndex = 4
105 Top = 1920
106 Width = 1215
107 End
108 Begin VB.Label Label1
109 Caption = "Packet contents"
110 Height = 255
111 Left = 360
112 TabIndex = 1
113 Top = 360
114 Width = 2895
115 End
116 End
117 Attribute VB_Name = "Form1"
118 Attribute VB_GlobalNameSpace = False
119 Attribute VB_Creatable = False
120 Attribute VB_PredeclaredId = True
121 Attribute VB_Exposed = False
122 Dim filterHostname As String
123 Dim filterTCPPort As Integer
124 Dim filterUDPPort As Integer
125 Dim fileList As String
126 Dim lastModified As String
127
128 Dim protocolVersion As String
129 Dim connected As Boolean
130 Dim responseNumber As Integer
131
132
133 Private Sub Command1_Click()
134
135 ' Use the first winsock control to send a UDP packet.
136 Winsock1.RemoteHost = Text3.Text
137 Winsock1.RemotePort = Text2.Text
138 Winsock1.SendData Text1.Text
139
140 End Sub
141
142 Private Sub Command2_Click()
143
144 ' establish a TCP connection to a filtermanager
145 Winsock2.Close
146 Winsock2.Connect Text3.Text, Text2.Text
147
148 End Sub
149
150 Private Sub Command3_Click()
151 ' establish a TCP connection to a filter
152 Winsock2.Close
153 Winsock2.Connect filterHostname, filterTCPPort
154 End Sub
155
156 Private Sub Form_Load()
157 protocolVersion = "1.1"
158 End Sub
159
160 Private Sub Winsock2_Connect()
161
162 responseNumber = 0
163
164 ' Send something as soon as we connect to the server.
165 If connected = False Then
166 ' contact the FilterManager
167 Winsock2.SendData "STARTCONFIG" & vbCrLf
168 Else
169 ' Contact the Filter
170 Winsock2.SendData "HEARTBEAT" & vbCrLf
171 End If
172
173 End Sub
174
175 Private Sub Winsock2_DataArrival(ByVal bytesTotal As Long)
176
177 responseNumber = responseNumber + 1
178
179 ' Get the line from the server.
180 Winsock2.GetData response, vbString, bytesTotal
181
182 ' Remove linefeeds and returns from the line.
183 response = Replace(response, Chr(13), "")
184 response = Replace(response, Chr(10), "")
185 Text4.Text = Text4.Text & vbCrLf & response
186
187 If connected = False Then
188 ' Perform TCP configuration (1.1)
189 On Error GoTo configError
190 Select Case responseNumber
191 Case 1:
192 If Not response = "OK" Then GoTo configError
193 Winsock2.SendData "LASTMODIFIED" & vbCrLf
194 Case 2:
195 If response = "ERROR" Then GoTo configError
196 lastModified = response
197 Winsock2.SendData "FILELIST" & vbCrLf
198 Case 3:
199 If response = "ERROR" Then GoTo configError
200 fileList = response
201 Winsock2.SendData "UDPUpdateTime" & vbCrLf
202 Case 4:
203 If response = "ERROR" Then GoTo configError
204 Winsock2.SendData "TCPUpdateTime" & vbCrLf
205 Case 5:
206 If response = "ERROR" Then GoTo configError
207 Winsock2.SendData "ENDCONFIG" & vbCrLf
208 Case 6:
209 If Not response = "OK" Then GoTo configError
210 Winsock2.SendData "FILTER" & vbCrLf
211 Case 7:
212 'we got a filter list here.
213 readTo = 0
214 ' get hostname
215 readTo = InStr(1, response, ";", vbBinaryCompare)
216 filterHostname = Mid(response, 1, readTo - 1)
217 response = Mid(response, readTo + 1, Len(response))
218 ' get UDP Port number
219 readTo = InStr(1, response, ";")
220 filterUDPPort = Mid(response, 1, readTo - 1)
221 response = Mid(response, readTo + 1, Len(response))
222 ' get TCP Port number
223 filterTCPPort = response
224 Winsock2.SendData "END" & vbCrLf
225 Case 8:
226 If Not response = "OK" Then GoTo configError
227 connected = True
228 responseNumber = 0
229 Winsock2.Close
230 Text4.Text = Text4.Text & vbCrLf & " <closed>"
231 x = MsgBox("got config okay")
232 End Select
233 Else
234 ' Perform a heartbeat (1.1)
235 On Error GoTo heartbeatError
236 Select Case responseNumber
237 Case 1:
238 If Not response = "OK" Then GoTo heartbeatError
239 Winsock2.SendData "CONFIG" & vbCrLf
240 Case 2:
241 If Not response = "OK" Then GoTo heartbeatError
242 Winsock2.SendData fileList & vbCrLf
243 Case 3:
244 If Not response = "OK" Then GoTo heartbeatError
245 Winsock2.SendData lastModified & vbCrLf
246 Case 4:
247 If Not response = "OK" Then GoTo heartbeatError
248 Winsock2.SendData "ENDHEARTBEAT" & vbCrLf
249 Case 5:
250 If Not response = "OK" Then GoTo heartbeatError
251 Winsock2.Close
252 x = MsgBox("heartbeat sent okay.")
253 End Select
254
255 End If
256
257
258 Exit Sub
259
260 configError:
261 x = MsgBox("error doing configuration")
262 heartbeatError:
263
264 End Sub