ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/experimental/host/vb_net_test/nettest.frm
(Generate patch)

Comparing experimental/host/vb_net_test/nettest.frm (file contents):
Revision 1.18 by pjm2, Fri Feb 23 17:51:07 2001 UTC vs.
Revision 1.29 by pjm2, Wed Feb 28 10:45:37 2001 UTC

# Line 4 | Line 4 | Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0
4   Begin VB.Form Form1
5     BorderStyle     =   3  'Fixed Dialog
6     Caption         =   "i-scream Winhost"
7 <   ClientHeight    =   5655
7 >   ClientHeight    =   1185
8     ClientLeft      =   45
9     ClientTop       =   330
10     ClientWidth     =   4710
11 +   Icon            =   "nettest.frx":0000
12     LinkTopic       =   "Form1"
13     MaxButton       =   0   'False
14     MinButton       =   0   'False
15 <   ScaleHeight     =   5655
15 >   ScaleHeight     =   1185
16     ScaleWidth      =   4710
17     ShowInTaskbar   =   0   'False
18 <   StartUpPosition =   3  'Windows Default
19 <   Begin VB.CommandButton Hide
20 <      Caption         =   "Hide Window"
21 <      Height          =   375
22 <      Left            =   3120
23 <      TabIndex        =   7
18 >   StartUpPosition =   2  'CenterScreen
19 >   Visible         =   0   'False
20 >   Begin VB.CommandButton Command1
21 >      Caption         =   "more"
22 >      Height          =   255
23 >      Left            =   3960
24 >      TabIndex        =   8
25        Top             =   840
26 <      Width           =   1455
26 >      Width           =   615
27     End
28 +   Begin VB.TextBox Text1
29 +      Height          =   2055
30 +      Left            =   120
31 +      Locked          =   -1  'True
32 +      MultiLine       =   -1  'True
33 +      ScrollBars      =   2  'Vertical
34 +      TabIndex        =   7
35 +      Top             =   1200
36 +      Width           =   4455
37 +   End
38 +   Begin VB.CommandButton Hide
39 +      Caption         =   "hide"
40 +      Height          =   255
41 +      Left            =   3960
42 +      TabIndex        =   6
43 +      Top             =   480
44 +      Width           =   615
45 +   End
46     Begin SysTray.SystemTray SystemTray
47 <      Left            =   2160
48 <      Top             =   1800
47 >      Left            =   2520
48 >      Top             =   4200
49        _ExtentX        =   847
50        _ExtentY        =   847
51        SysTrayText     =   "i-scream Winhost"
52        IconFile        =   0
53     End
54     Begin VB.Timer Timer1
55 <      Left            =   2760
56 <      Top             =   1800
55 >      Left            =   3120
56 >      Top             =   4200
57     End
38   Begin VB.TextBox Text4
39      Height          =   1575
40      Left            =   240
41      MultiLine       =   -1  'True
42      ScrollBars      =   2  'Vertical
43      TabIndex        =   1
44      Text            =   "nettest.frx":0000
45      Top             =   3000
46      Width           =   3975
47   End
58     Begin VB.CommandButton Reconfigure
59        Caption         =   "Reconfigure with FilterManager"
60        Height          =   375
61 <      Left            =   120
61 >      Left            =   840
62        TabIndex        =   0
63 <      Top             =   840
63 >      Top             =   3480
64        Width           =   2895
65     End
66     Begin MSWinsockLib.Winsock TCPSock
67 <      Left            =   3720
68 <      Top             =   1800
67 >      Left            =   4080
68 >      Top             =   4200
69        _ExtentX        =   741
70        _ExtentY        =   741
71        _Version        =   393216
72     End
73     Begin MSWinsockLib.Winsock UDPSock
74 <      Left            =   3240
75 <      Top             =   1800
74 >      Left            =   3600
75 >      Top             =   4200
76        _ExtentX        =   741
77        _ExtentY        =   741
78        _Version        =   393216
79        Protocol        =   1
80     End
71   Begin VB.Label Label5
72      Caption         =   "b e t a"
73      BeginProperty Font
74         Name            =   "MS Sans Serif"
75         Size            =   24
76         Charset         =   0
77         Weight          =   700
78         Underline       =   0   'False
79         Italic          =   0   'False
80         Strikethrough   =   0   'False
81      EndProperty
82      Height          =   615
83      Left            =   240
84      TabIndex        =   8
85      Top             =   120
86      Width           =   1815
87   End
81     Begin VB.Label Label2
82        Alignment       =   1  'Right Justify
83        Caption         =   "Next heartbeat:"
84        Height          =   255
85 <      Left            =   2400
86 <      TabIndex        =   6
85 >      Left            =   120
86 >      TabIndex        =   5
87        Top             =   480
88        Width           =   1455
89     End
# Line 98 | Line 91 | Begin VB.Form Form1
91        Alignment       =   1  'Right Justify
92        Caption         =   "Next UDP packet:"
93        Height          =   255
94 <      Left            =   2400
95 <      TabIndex        =   5
94 >      Left            =   120
95 >      TabIndex        =   4
96        Top             =   120
97        Width           =   1455
98     End
# Line 107 | Line 100 | Begin VB.Form Form1
100        BorderStyle     =   1  'Fixed Single
101        Caption         =   "0"
102        Height          =   255
103 <      Left            =   3960
104 <      TabIndex        =   4
103 >      Left            =   1680
104 >      TabIndex        =   3
105        Top             =   480
106        Width           =   615
107     End
# Line 116 | Line 109 | Begin VB.Form Form1
109        BorderStyle     =   1  'Fixed Single
110        Caption         =   "0"
111        Height          =   255
112 <      Left            =   3960
113 <      TabIndex        =   3
112 >      Left            =   1680
113 >      TabIndex        =   2
114        Top             =   120
115        Width           =   615
116     End
# Line 126 | Line 119 | Begin VB.Form Form1
119        Caption         =   "Status:"
120        Height          =   255
121        Left            =   0
122 <      TabIndex        =   2
123 <      Top             =   1320
124 <      Width           =   4695
122 >      TabIndex        =   1
123 >      Top             =   840
124 >      Width           =   3855
125     End
126   End
127   Attribute VB_Name = "Form1"
# Line 158 | Line 151 | Dim TCPUpdateTime As Integer
151   Dim protocolVersion As String
152   Dim connected As Boolean
153  
154 < 'Dim CUpTime As New CUpTime
154 > Dim CUpTime As New CUpTime
155 > Dim wksta As New CNetWksta
156  
157 + Dim windowBig As Boolean
158 +
159   Dim responseNumber As Integer
160  
161 + Private Sub Command1_Click()
162 +
163 +    ' Toggle visibility of the debug output.
164 +
165 +    If windowBig Then
166 +        Form1.Height = 1500
167 +        windowBig = False
168 +    Else
169 +        Form1.Height = 4350
170 +        windowBig = True
171 +    End If
172 +
173 + End Sub
174 +
175   Private Sub Form_Load()
176      
177 +    If App.PrevInstance Then
178 +        x = MsgBox("There is already an i-scream Winhost running on this machine.", 48, "i-scream host already running")
179 +        End
180 +    End If
181 +    
182      protocolVersion = "1.1"
183      
184      Status.Caption = "Loading"
185 <    'Form1.Caption = "i-scream Winhost " & protocolVersion & " for " & GetVersion()
185 >    Form1.Caption = "i-scream Winhost " & protocolVersion
186      
187 +    CUpTime.Init
188 +    
189 +    If CUpTime.isWin9x Then
190 +        x = MsgBox("Sorry, the i-scream host can only be used to monitor servers (i.e. not Win9x)", 48, "Not a server")
191 +        End
192 +    End If
193 +    
194 +    windowBig = False
195 +    
196      ''''TEMP
197      'filterManagerHostname = "killigrew.ukc.ac.uk"
198      'filterManagerTCPPort = 4567
# Line 182 | Line 206 | Private Sub Form_Load()
206      filterManagerHostname = Left$(buf, length)
207      length = GetPrivateProfileInt("i-scream Winhost", "FilterManagerPort", 0, App.Path & "/winhost.ini")
208      filterManagerTCPPort = length
209 +    If filterManagerHostname = "" Then
210 +        GoTo iniError
211 +    End If
212 +    On Error GoTo 0
213   skip:
214  
215      Status.Caption = "Connecting to Filter Manager " & filterManagerHostname & ":" & filterManagerTCPPort
216      Reconfigure_Click
217      
218 <    Form1.Show
218 >    SystemTray.Icon = Val(Form1.Icon)
219      SystemTray.Action = 0
220      
221      
# Line 227 | Line 255 | Private Sub SystemTray_MouseDblClk(ByVal Button As Int
255  
256      Form1.Visible = True
257      Form1.SetFocus
230    
258  
259   End Sub
260  
# Line 256 | Line 283 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
283      ' Remove linefeeds and returns from the line.
284      response = Replace(response, Chr(13), "")
285      response = Replace(response, Chr(10), "")
259    Text4.Text = Text4.Text & vbCrLf & response
286      
287      If connected = False Then
288          ' Perform TCP configuration (1.1)
# Line 265 | Line 291 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
291              Case 1:
292                  If Not response = "OK" Then GoTo configError
293                  TCPSock.SendData "LASTMODIFIED" & vbCrLf
294 +                Text1.Text = "Requesting configuration from FilterManager:- " & vbCrLf
295 +                Text1.Text = Text1.Text & response & vbCrLf
296              Case 2:
297                  If response = "ERROR" Then GoTo configError
298                  lastModified = response
299 +                Text1.Text = Text1.Text & response & vbCrLf
300                  TCPSock.SendData "FILELIST" & vbCrLf
301 +            ' New addition to the protocol.
302              Case 3:
303                  If response = "ERROR" Then GoTo configError
304                  fileList = response
305 <                TCPSock.SendData "UDPUpdateTime" & vbCrLf
305 >                Text1.Text = Text1.Text & response & vbCrLf
306 >                TCPSock.SendData "FQDN" & vbCrLf
307              Case 4:
308                  If response = "ERROR" Then GoTo configError
309 +                Text1.Text = Text1.Text & response & vbCrLf
310 +                machineName = response
311 +                TCPSock.SendData "UDPUpdateTime" & vbCrLf
312 +            Case 5:
313 +                If response = "ERROR" Then GoTo configError
314                  UDPUpdateTime = response
315 +                Text1.Text = Text1.Text & response & vbCrLf
316                  TCPSock.SendData "TCPUpdateTime" & vbCrLf
317 <            Case 5:
317 >            Case 6:
318                  If response = "ERROR" Then GoTo configError
319                  TCPUpdateTime = response
320 +                Text1.Text = Text1.Text & response & vbCrLf
321                  TCPSock.SendData "ENDCONFIG" & vbCrLf
322 <            Case 6:
322 >            Case 7:
323                  If Not response = "OK" Then GoTo configError
324 +                Text1.Text = Text1.Text & response & vbCrLf
325                  TCPSock.SendData "FILTER" & vbCrLf
326 <            Case 7:
326 >            Case 8:
327 >                Text1.Text = Text1.Text & response & vbCrLf
328                  'we got a filter list here.
329                  readTo = 0
330                  ' get hostname
# Line 298 | Line 338 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
338                  ' get TCP Port number
339                  filterTCPPort = response
340                  TCPSock.SendData "END" & vbCrLf
341 <            Case 8:
341 >            Case 9:
342                  If Not response = "OK" Then GoTo configError
343                  connected = True
344                  responseNumber = 0
345                  TCPSock.Close
346 <                Text4.Text = Text4.Text & vbCrLf & "  <closed>"
346 >                Text1.Text = Text1.Text & response & vbCrLf
347 >                'Text4.Text = Text4.Text & vbCrLf & "  <closed>"
348                  Status.Caption = "Configuration successful"
349                  Label3.Caption = UDPUpdateTime
350                  Label4.Caption = TCPUpdateTime
# Line 315 | Line 356 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
356          Select Case responseNumber
357              Case 1:
358                  If Not response = "OK" Then GoTo heartbeatError
359 +                Text1.Text = "Performing heartbeat: -" & vbCrLf
360 +                Text1.Text = Text1.Text & response & vbCrLf
361                  TCPSock.SendData "CONFIG" & vbCrLf
362              Case 2:
363                  If Not response = "OK" Then GoTo heartbeatError
364 +                Text1.Text = Text1.Text & response & vbCrLf
365                  TCPSock.SendData fileList & vbCrLf
366              Case 3:
367                  If Not response = "OK" Then GoTo heartbeatError
368 +                Text1.Text = Text1.Text & response & vbCrLf
369                  TCPSock.SendData lastModified & vbCrLf
370              Case 4:
371                  If Not response = "OK" Then GoTo heartbeatError
372 +                Text1.Text = Text1.Text & response & vbCrLf
373                  TCPSock.SendData "ENDHEARTBEAT" & vbCrLf
374              Case 5:
375                  If Not response = "OK" Then GoTo heartbeatError
376 +                Text1.Text = Text1.Text & response & vbCrLf
377                  TCPSock.Close
378                  Status.Caption = "Heartbeat sent successfully."
379          End Select
# Line 355 | Line 402 | Private Sub Timer1_Timer()
402          
403          ' prepare the contents of the XML packet.
404          seqNo = seqNo + 1
405 <        machineName = TCPSock.LocalHostName
405 >        
406 >        ' Comment this line in the next protocol
407 >        'machineName = TCPSock.LocalHostName
408 >        
409          LocalIP = TCPSock.LocalIP
410          packetDate = Date2Num()
411          
# Line 368 | Line 418 | Private Sub Timer1_Timer()
418              End
419          End If
420            
421 <        osName = getVersion()
421 >        osName = GetVersion()
422          osVersionMajor = verinfo.dwMajorVersion
423          osVersionMinor = verinfo.dwMinorVersion
424          osBuild = verinfo.dwBuildNumber
# Line 394 | Line 444 | Private Sub Timer1_Timer()
444          Dim memory&
445          GlobalMemoryStatus memsts
446          memory& = memsts.dwTotalPhys
447 <        memTotal = memory& \ 1024
447 >        memTotal = memory& \ 1048576
448          memory& = memsts.dwAvailPhys
449 <        memFree = memory& \ 1024
449 >        memFree = memory& \ 1048576
450          memory& = memsts.dwTotalVirtual
451 <        swapTotal = memory& \ 1024
451 >        swapTotal = memory& \ 1048576
452          memory& = memsts.dwAvailVirtual
453 <        swapFree = memory& \ 1024
453 >        swapFree = memory& \ 1048576
454          
455 +        uptime = CUpTime.MilliSecs \ 1000
456 +        
457 +        CUpTime.Capture
458 +        cpu_time = CUpTime.CPUTime
459 +        percent_idle = CUpTime.PercentIdle
460 +        
461 +        userCount = wksta.LoggedOnUsers
462 +        
463          ' build the contents of the XML packet
464          xml = "<packet seq_no=""" & seqNo & """ machine_name=""" & machineName & """ date=""" & packetDate & """ type=""data"" ip=""" & LocalIP & """>" & _
465                "<os>" & _
# Line 411 | Line 469 | Private Sub Timer1_Timer()
469                  "<platform>" & osName & "</platform>" & _
470                  "<minor_version>" & osVersionMinor & "</minor_version>" & _
471                  "<processor>" & processorType & "</processor>" & _
472 +                "<uptime>" & uptime & "</uptime>" & _
473                "</os>" & _
474 +              "<users><count>" & userCount & "</count></users>" & _
475 +              "<cpu><idle>" & percent_idle & "</idle><user>" & cpu_time & "</user></cpu>" & _
476                "<memory><total>" & memTotal & "</total><free>" & memFree & "</free></memory>" & _
477                "<swap><total>" & swapTotal & "</total><free>" & swapFree & "</free></swap>" & _
478                "</packet>"
479 <        Text4.Text = Text4.Text + xml
479 >        Text1.Text = "Last packet contained: -" & vbCrLf & xml
480  
481          ' Use the first winsock control to send a UDP packet.
482          UDPSock.RemoteHost = filterHostname

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines