ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/experimental/host/vb_net_test/nettest.frm
(Generate patch)

Comparing experimental/host/vb_net_test/nettest.frm (file contents):
Revision 1.2 by pjm2, Fri Feb 23 09:42:36 2001 UTC vs.
Revision 1.25 by pjm2, Wed Feb 28 08:19:00 2001 UTC

# Line 1 | Line 1
1   VERSION 5.00
2   Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX"
3 + Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0"; "SysTray.ocx"
4   Begin VB.Form Form1
5     BorderStyle     =   3  'Fixed Dialog
6 <   Caption         =   "TCP/UDP Test program"
7 <   ClientHeight    =   5655
6 >   Caption         =   "i-scream Winhost"
7 >   ClientHeight    =   1275
8     ClientLeft      =   45
9     ClientTop       =   330
10 <   ClientWidth     =   5670
10 >   ClientWidth     =   4710
11 >   Icon            =   "nettest.frx":0000
12     LinkTopic       =   "Form1"
13     MaxButton       =   0   'False
14     MinButton       =   0   'False
15 <   ScaleHeight     =   5655
16 <   ScaleWidth      =   5670
15 >   ScaleHeight     =   1275
16 >   ScaleWidth      =   4710
17     ShowInTaskbar   =   0   'False
18 <   StartUpPosition =   3  'Windows Default
19 <   Begin VB.CommandButton Command3
20 <      Caption         =   "TCP to Filter"
18 >   StartUpPosition =   2  'CenterScreen
19 >   Visible         =   0   'False
20 >   Begin VB.CommandButton Hide
21 >      Caption         =   "Hide Window"
22        Height          =   375
23 <      Left            =   3720
24 <      TabIndex        =   9
25 <      Top             =   2520
26 <      Width           =   1575
23 >      Left            =   3120
24 >      TabIndex        =   6
25 >      Top             =   480
26 >      Width           =   1455
27     End
28 <   Begin VB.TextBox Text4
29 <      Height          =   2535
30 <      Left            =   240
31 <      MultiLine       =   -1  'True
32 <      ScrollBars      =   2  'Vertical
33 <      TabIndex        =   8
34 <      Text            =   "nettest.frx":0000
32 <      Top             =   3000
33 <      Width           =   5055
28 >   Begin SysTray.SystemTray SystemTray
29 >      Left            =   2160
30 >      Top             =   1800
31 >      _ExtentX        =   847
32 >      _ExtentY        =   847
33 >      SysTrayText     =   "i-scream Winhost"
34 >      IconFile        =   0
35     End
36 <   Begin VB.CommandButton Command2
37 <      Caption         =   "TCP to FilterManager"
36 >   Begin VB.Timer Timer1
37 >      Left            =   2760
38 >      Top             =   1800
39 >   End
40 >   Begin VB.CommandButton Reconfigure
41 >      Caption         =   "Reconfigure with FilterManager"
42        Height          =   375
43 <      Left            =   3360
44 <      TabIndex        =   7
45 <      Top             =   2040
46 <      Width           =   1935
43 >      Left            =   120
44 >      TabIndex        =   0
45 >      Top             =   480
46 >      Width           =   2895
47     End
48 <   Begin MSWinsockLib.Winsock Winsock2
49 <      Left            =   4920
50 <      Top             =   120
48 >   Begin MSWinsockLib.Winsock TCPSock
49 >      Left            =   3720
50 >      Top             =   1800
51        _ExtentX        =   741
52        _ExtentY        =   741
53        _Version        =   393216
54     End
55 <   Begin VB.TextBox Text3
56 <      Height          =   285
57 <      Left            =   1680
53 <      TabIndex        =   5
54 <      Text            =   "killigrew.ukc.ac.uk"
55 <      Top             =   1560
56 <      Width           =   2535
57 <   End
58 <   Begin VB.TextBox Text2
59 <      Height          =   285
60 <      Left            =   1680
61 <      TabIndex        =   3
62 <      Text            =   "4567"
63 <      Top             =   1920
64 <      Width           =   855
65 <   End
66 <   Begin VB.CommandButton Command1
67 <      Caption         =   "Send UDP"
68 <      Height          =   375
69 <      Left            =   4320
70 <      TabIndex        =   2
71 <      Top             =   1560
72 <      Width           =   975
73 <   End
74 <   Begin VB.TextBox Text1
75 <      Height          =   855
76 <      Left            =   360
77 <      TabIndex        =   0
78 <      Text            =   "<packet></packet>"
79 <      Top             =   600
80 <      Width           =   4935
81 <   End
82 <   Begin MSWinsockLib.Winsock Winsock1
83 <      Left            =   4320
84 <      Top             =   120
55 >   Begin MSWinsockLib.Winsock UDPSock
56 >      Left            =   3240
57 >      Top             =   1800
58        _ExtentX        =   741
59        _ExtentY        =   741
60        _Version        =   393216
61        Protocol        =   1
62     End
63 <   Begin VB.Label Label3
63 >   Begin VB.Label Label2
64        Alignment       =   1  'Right Justify
65 <      Caption         =   "Destination:"
65 >      Caption         =   "Next heartbeat:"
66        Height          =   255
67 <      Left            =   360
68 <      TabIndex        =   6
69 <      Top             =   1560
70 <      Width           =   1215
67 >      Left            =   2400
68 >      TabIndex        =   5
69 >      Top             =   120
70 >      Width           =   1455
71     End
72 <   Begin VB.Label Label2
72 >   Begin VB.Label Label1
73        Alignment       =   1  'Right Justify
74 <      Caption         =   "Port:"
74 >      Caption         =   "Next UDP packet:"
75        Height          =   255
76 <      Left            =   360
76 >      Left            =   120
77        TabIndex        =   4
78 <      Top             =   1920
79 <      Width           =   1215
78 >      Top             =   120
79 >      Width           =   1455
80     End
81 <   Begin VB.Label Label1
82 <      Caption         =   "Packet contents"
81 >   Begin VB.Label Label4
82 >      BorderStyle     =   1  'Fixed Single
83 >      Caption         =   "0"
84        Height          =   255
85 <      Left            =   360
85 >      Left            =   3960
86 >      TabIndex        =   3
87 >      Top             =   120
88 >      Width           =   615
89 >   End
90 >   Begin VB.Label Label3
91 >      BorderStyle     =   1  'Fixed Single
92 >      Caption         =   "0"
93 >      Height          =   255
94 >      Left            =   1680
95 >      TabIndex        =   2
96 >      Top             =   120
97 >      Width           =   615
98 >   End
99 >   Begin VB.Label Status
100 >      Alignment       =   2  'Center
101 >      Caption         =   "Status:"
102 >      Height          =   255
103 >      Left            =   0
104        TabIndex        =   1
105 <      Top             =   360
106 <      Width           =   2895
105 >      Top             =   960
106 >      Width           =   4695
107     End
108   End
109   Attribute VB_Name = "Form1"
# Line 119 | Line 111 | Attribute VB_GlobalNameSpace = False
111   Attribute VB_Creatable = False
112   Attribute VB_PredeclaredId = True
113   Attribute VB_Exposed = False
114 + ' For the system tray bits
115 + Private Declare Function GetPrivateProfileString Lib "kernel32" Alias "GetPrivateProfileStringA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal lpDefault As String, ByVal lpReturnedString As String, ByVal nSize As Long, ByVal lpFileName As String) As Long
116 + Private Declare Function GetPrivateProfileInt Lib "kernel32" Alias "GetPrivateProfileIntA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal nDefault As Long, ByVal lpFileName As String) As Long
117 +
118 + Dim filterManagerHostname As String
119 + Dim filterManagerTCPPort As Long
120 +
121 + Dim seqNo As Long
122 + Dim machineName As String
123 +
124   Dim filterHostname As String
125 < Dim filterTCPPort As String
126 < Dim filterUDPPort As String
125 > Dim filterTCPPort As Integer
126 > Dim filterUDPPort As Integer
127 > Dim fileList As String
128 > Dim lastModified As String
129  
130 + Dim UDPUpdateTime As Integer
131 + Dim TCPUpdateTime As Integer
132 +
133   Dim protocolVersion As String
134   Dim connected As Boolean
128 Dim responseNumber As Integer
135  
136 + Dim CUpTime As New CUpTime
137 + Dim wksta As New CNetWksta
138  
139 < Private Sub Command1_Click()
139 > Dim responseNumber As Integer
140  
141 <    ' Use the first winsock control to send a UDP packet.
142 <    Winsock1.RemoteHost = Text3.Text
143 <    Winsock1.RemotePort = Text2.Text
144 <    Winsock1.SendData Text1.Text
141 > Private Sub Form_Load()
142 >    
143 >    If App.PrevInstance Then
144 >        x = MsgBox("There is already an i-scream Winhost running on this machine.", 48, "i-scream host already running")
145 >        End
146 >    End If
147 >    
148 >    protocolVersion = "1.1"
149 >    
150 >    Status.Caption = "Loading"
151 >    Form1.Caption = "i-scream Winhost " & protocolVersion
152 >    
153 >    CUpTime.Init
154 >    
155 >    If CUpTime.isWin9x Then
156 >        x = MsgBox("Sorry, the i-scream host can only be used to monitor servers (i.e. not Win9x)", 48, "Not a server")
157 >        End
158 >    End If
159 >    
160 >    ''''TEMP
161 >    'filterManagerHostname = "killigrew.ukc.ac.uk"
162 >    'filterManagerTCPPort = 4567
163 >    ''''' END TEMP
164 >    
165 >    'GoTo skip
166 >    On Error GoTo iniError
167 >    Dim buf As String * 256
168 >    Dim length As Long
169 >    length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "<no value>", buf, Len(buf), App.Path & "/winhost.ini")
170 >    filterManagerHostname = Left$(buf, length)
171 >    length = GetPrivateProfileInt("i-scream Winhost", "FilterManagerPort", 0, App.Path & "/winhost.ini")
172 >    filterManagerTCPPort = length
173 >    If filterManagerHostname = "" Then
174 >        GoTo iniError
175 >    End If
176 >    On Error GoTo 0
177 > skip:
178  
179 +    Status.Caption = "Connecting to Filter Manager " & filterManagerHostname & ":" & filterManagerTCPPort
180 +    Reconfigure_Click
181 +    
182 +    SystemTray.Icon = Val(Form1.Icon)
183 +    SystemTray.Action = 0
184 +    
185 +    
186 +    Exit Sub
187 +    
188 + iniError:
189 +    x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file.  Please correct these and try again.  " & Err.Description, 48, "Configuration not found")
190 +    End
191 +    
192   End Sub
193  
194 < Private Sub Command2_Click()
195 <    
196 <    ' establish a TCP connection to a machine
197 <    Winsock2.Close
198 <    Winsock2.Connect Text3.Text, Text2.Text
194 > Private Sub Form_QueryUnload(Cancel As Integer, UnloadMode As Integer)
195 >    x = MsgBox("Are you sure you want to shut down the Winhost?  This will stop your computer sending information to the i-scream Central Monitoring System.", vbYesNo, "i-scream Winhost")
196 >    If x = 7 Then
197 >        Cancel = True
198 >    Else
199 >        SystemTray.Action = 2
200 >    End If
201  
202   End Sub
203  
204 < Private Sub Command3_Click()
205 <    x = MsgBox("not implemented..")
204 > Private Sub Hide_Click()
205 >    Form1.Visible = False
206 >    SystemTray.Icon = Val(Form1.Icon)
207   End Sub
208  
209 < Private Sub Form_Load()
210 <    protocolVersion = "1.1"
209 > Private Sub Reconfigure_Click()
210 >    ' establish a TCP connection to a filtermanager
211 >    connected = False
212 >    TCPSock.Close
213 >    TCPSock.Connect filterManagerHostname, filterManagerTCPPort
214   End Sub
215  
216 < Private Sub Winsock2_Connect()
217 <      
218 <   responseNumber = 0
216 >
217 >
218 > Private Sub SystemTray_MouseDblClk(ByVal Button As Integer)
219 >
220 >    Form1.Visible = True
221 >    Form1.SetFocus
222 >
223 > End Sub
224 >
225 > Private Sub TCPSock_Connect()
226 >    
227 >    responseNumber = 0
228    
229 <   ' As soon as we are connected to the server, send this.
230 <   Winsock2.SendData "STARTCONFIG" & vbCrLf
229 >    ' Send something as soon as we connect to the server.
230 >    If connected = False Then
231 >        ' contact the FilterManager
232 >        TCPSock.SendData "STARTCONFIG" & vbCrLf
233 >    Else
234 >       ' Contact the Filter
235 >       TCPSock.SendData "HEARTBEAT" & vbCrLf
236 >    End If
237    
238   End Sub
239  
240 < Private Sub Winsock2_DataArrival(ByVal bytesTotal As Long)
240 > Private Sub TCPSock_DataArrival(ByVal bytesTotal As Long)
241      
242      responseNumber = responseNumber + 1
243      
244      ' Get the line from the server.
245 <    Winsock2.GetData response, vbString, bytesTotal
245 >    TCPSock.GetData response, vbString, bytesTotal
246      
247      ' Remove linefeeds and returns from the line.
248      response = Replace(response, Chr(13), "")
249      response = Replace(response, Chr(10), "")
250 <    Text4.Text = Text4.Text & vbCrLf & response
250 >    'Text4.Text = Text4.Text & vbCrLf & response
251      
252      If connected = False Then
253          ' Perform TCP configuration (1.1)
# Line 180 | Line 255 | Private Sub Winsock2_DataArrival(ByVal bytesTotal As L
255          Select Case responseNumber
256              Case 1:
257                  If Not response = "OK" Then GoTo configError
258 <                Winsock2.SendData "LASTMODIFIED" & vbCrLf
258 >                TCPSock.SendData "LASTMODIFIED" & vbCrLf
259              Case 2:
260                  If response = "ERROR" Then GoTo configError
261 <                Winsock2.SendData "FILELIST" & vbCrLf
261 >                lastModified = response
262 >                TCPSock.SendData "FILELIST" & vbCrLf
263              Case 3:
264                  If response = "ERROR" Then GoTo configError
265 <                Winsock2.SendData "UDPUpdateTime" & vbCrLf
265 >                fileList = response
266 >                TCPSock.SendData "UDPUpdateTime" & vbCrLf
267              Case 4:
268                  If response = "ERROR" Then GoTo configError
269 <                Winsock2.SendData "TCPUpdateTime" & vbCrLf
269 >                UDPUpdateTime = response
270 >                TCPSock.SendData "TCPUpdateTime" & vbCrLf
271              Case 5:
272                  If response = "ERROR" Then GoTo configError
273 <                Winsock2.SendData "ENDCONFIG" & vbCrLf
273 >                TCPUpdateTime = response
274 >                TCPSock.SendData "ENDCONFIG" & vbCrLf
275              Case 6:
276                  If Not response = "OK" Then GoTo configError
277 <                Winsock2.SendData "FILTER" & vbCrLf
277 >                TCPSock.SendData "FILTER" & vbCrLf
278              Case 7:
279                  'we got a filter list here.
280                  readTo = 0
# Line 209 | Line 288 | Private Sub Winsock2_DataArrival(ByVal bytesTotal As L
288                  response = Mid(response, readTo + 1, Len(response))
289                  ' get TCP Port number
290                  filterTCPPort = response
291 <                Winsock2.SendData "END" & vbCrLf
291 >                TCPSock.SendData "END" & vbCrLf
292              Case 8:
293                  If Not response = "OK" Then GoTo configError
294                  connected = True
295                  responseNumber = 0
296 <                Winsock2.Close
297 <                Text4.Text = Text4.Text & vbCrLf & "  <closed>"
298 <                x = MsgBox("got config okay")
296 >                TCPSock.Close
297 >                'Text4.Text = Text4.Text & vbCrLf & "  <closed>"
298 >                Status.Caption = "Configuration successful"
299 >                Label3.Caption = UDPUpdateTime
300 >                Label4.Caption = TCPUpdateTime
301 >                Timer1.Interval = 1000
302          End Select
303      Else
304          ' Perform a heartbeat (1.1)
305          On Error GoTo heartbeatError
306          Select Case responseNumber
307              Case 1:
308 <                
308 >                If Not response = "OK" Then GoTo heartbeatError
309 >                TCPSock.SendData "CONFIG" & vbCrLf
310              Case 2:
311 <                
311 >                If Not response = "OK" Then GoTo heartbeatError
312 >                TCPSock.SendData fileList & vbCrLf
313              Case 3:
314 <                
314 >                If Not response = "OK" Then GoTo heartbeatError
315 >                TCPSock.SendData lastModified & vbCrLf
316              Case 4:
317 <                
317 >                If Not response = "OK" Then GoTo heartbeatError
318 >                TCPSock.SendData "ENDHEARTBEAT" & vbCrLf
319              Case 5:
320 <                
321 <            Case 6:
322 <                
237 <            Case 7:
238 <                
239 <            Case 8:
240 <                
320 >                If Not response = "OK" Then GoTo heartbeatError
321 >                TCPSock.Close
322 >                Status.Caption = "Heartbeat sent successfully."
323          End Select
324      
325      End If
# Line 246 | Line 328 | Private Sub Winsock2_DataArrival(ByVal bytesTotal As L
328      Exit Sub
329      
330   configError:
331 <    x = MsgBox("error doing configuration")
331 >    Status.Caption = "FAILED to get configuration"
332 >    Exit Sub
333   heartbeatError:
334 +    Status.Caption = "Heatbeat FAILED"
335 +    Exit Sub
336 + End Sub
337 +
338 + Private Sub Timer1_Timer()
339 +
340 +    Label3.Caption = Label3.Caption - 1
341 +    Label4.Caption = Label4.Caption - 1
342      
343 +    Status.Caption = ""
344 +    
345 +    If Label3.Caption < 1 Then
346 +        
347 +        ' prepare the contents of the XML packet.
348 +        seqNo = seqNo + 1
349 +        machineName = TCPSock.LocalHostName
350 +        LocalIP = TCPSock.LocalIP
351 +        packetDate = Date2Num()
352 +        
353 +        
354 +        Dim verinfo As OSVERSIONINFO
355 +        verinfo.dwOSVersionInfoSize = Len(verinfo)
356 +        ret% = GetVersionEx(verinfo)
357 +        If ret% = 0 Then
358 +            MsgBox "Error getting Windows version Information"
359 +            End
360 +        End If
361 +          
362 +        osName = GetVersion()
363 +        osVersionMajor = verinfo.dwMajorVersion
364 +        osVersionMinor = verinfo.dwMinorVersion
365 +        osBuild = verinfo.dwBuildNumber
366 +        
367 +        Dim sysinfo As SYSTEM_INFO
368 +        GetSystemInfo sysinfo
369 +        Select Case sysinfo.dwProcessorType
370 +            Case PROCESSOR_INTEL_386
371 +                processorType = "Intel 386"
372 +            Case PROCESSOR_INTEL_486
373 +                processorType = "Intel 486"
374 +            Case PROCESSOR_INTEL_PENTIUM
375 +                processorType = "Intel Pentium variant"
376 +            Case PROCESSOR_MIPS_R4000
377 +                processorType = "MIPS R4000"
378 +            Case PROCESSOR_ALPHA_21064
379 +                processorType = "DEC Alpha 21064"
380 +            Case Else
381 +                processorType = "(unknown)"
382 +        End Select
383 +        
384 +        Dim memsts As MEMORYSTATUS
385 +        Dim memory&
386 +        GlobalMemoryStatus memsts
387 +        memory& = memsts.dwTotalPhys
388 +        memTotal = memory& \ 1024
389 +        memory& = memsts.dwAvailPhys
390 +        memFree = memory& \ 1024
391 +        memory& = memsts.dwTotalVirtual
392 +        swapTotal = memory& \ 1024
393 +        memory& = memsts.dwAvailVirtual
394 +        swapFree = memory& \ 1024
395 +        
396 +        uptime = CUpTime.MilliSecs \ 1000
397 +        
398 +        CUpTime.Capture
399 +        cpu_time = CUpTime.CPUTime
400 +        percent_idle = CUpTime.PercentIdle
401 +        
402 +        ' build the contents of the XML packet
403 +        xml = "<packet seq_no=""" & seqNo & """ machine_name=""" & machineName & """ date=""" & packetDate & """ type=""data"" ip=""" & LocalIP & """>" & _
404 +              "<os>" & _
405 +                "<name>" & osName & "</name>" & _
406 +                "<version>" & osVersionMajor & "</version>" & _
407 +                "<release>" & osBuild & "</release>" & _
408 +                "<platform>" & osName & "</platform>" & _
409 +                "<minor_version>" & osVersionMinor & "</minor_version>" & _
410 +                "<processor>" & processorType & "</processor>" & _
411 +                "<uptime>" & uptime & "</uptime>" & _
412 +              "</os>" & _
413 +              "<cpu><idle>" & percent_idle & "</idle><user>" & cpu_time & "</user></cpu>" & _
414 +              "<memory><total>" & memTotal & "</total><free>" & memFree & "</free></memory>" & _
415 +              "<swap><total>" & swapTotal & "</total><free>" & swapFree & "</free></swap>" & _
416 +              "</packet>"
417 +        'Text4.Text = Text4.Text + xml
418 +
419 +        ' Use the first winsock control to send a UDP packet.
420 +        UDPSock.RemoteHost = filterHostname
421 +        UDPSock.RemotePort = filterUDPPort
422 +        UDPSock.SendData xml
423 +        Status.Caption = "UDP packet sent"
424 +        Label3.Caption = UDPUpdateTime
425 +    End If
426 +    
427 +    If Label4.Caption < 1 Then
428 +        ' establish a TCP connection to a filter
429 +        TCPSock.Close
430 +        TCPSock.Connect filterHostname, filterTCPPort
431 +        Label4.Caption = TCPUpdateTime
432 +    End If
433 +
434   End Sub
435 +
436 + Function Date2Num() As Long
437 +    Dim x As Long
438 +    x = DateDiff("s", "1-1-1970", Now)
439 +    Date2Num = x
440 + End Function

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines