ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/experimental/host/vb_net_test/nettest.frm
(Generate patch)

Comparing experimental/host/vb_net_test/nettest.frm (file contents):
Revision 1.7 by pjm2, Fri Feb 23 10:58:00 2001 UTC vs.
Revision 1.11 by pjm2, Fri Feb 23 11:56:43 2001 UTC

# Line 1 | Line 1
1   VERSION 5.00
2   Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX"
3 + Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0"; "SysTray.ocx"
4   Begin VB.Form Form1
5 <   BorderStyle     =   3  'Fixed Dialog
6 <   Caption         =   "TCP/UDP Test program"
5 >   BorderStyle     =   4  'Fixed ToolWindow
6 >   Caption         =   "i-scream Winhost"
7     ClientHeight    =   5655
8     ClientLeft      =   45
9 <   ClientTop       =   330
9 >   ClientTop       =   285
10     ClientWidth     =   5670
11     LinkTopic       =   "Form1"
12     MaxButton       =   0   'False
12   MinButton       =   0   'False
13     ScaleHeight     =   5655
14     ScaleWidth      =   5670
15     ShowInTaskbar   =   0   'False
16     StartUpPosition =   3  'Windows Default
17 <   Begin VB.Timer TCPTimer
18 <      Left            =   3360
19 <      Top             =   120
17 >   Begin VB.CommandButton Hide
18 >      Caption         =   "Hide"
19 >      Height          =   495
20 >      Left            =   1800
21 >      TabIndex        =   7
22 >      Top             =   2160
23 >      Width           =   1215
24     End
25 <   Begin VB.Timer UDPTimer
26 <      Left            =   3840
27 <      Top             =   120
25 >   Begin SysTray.SystemTray SystemTray
26 >      Left            =   3600
27 >      Top             =   1200
28 >      _ExtentX        =   847
29 >      _ExtentY        =   847
30 >      SysTrayText     =   "i-scream Winhost"
31 >      IconFile        =   0
32     End
33 <   Begin VB.CommandButton Command3
34 <      Caption         =   "TCP to Filter"
35 <      Height          =   375
28 <      Left            =   3720
29 <      TabIndex        =   3
30 <      Top             =   2520
31 <      Width           =   1575
33 >   Begin VB.Timer Timer1
34 >      Left            =   4200
35 >      Top             =   1200
36     End
37     Begin VB.TextBox Text4
38        Height          =   1575
39        Left            =   240
40        MultiLine       =   -1  'True
41        ScrollBars      =   2  'Vertical
42 <      TabIndex        =   2
42 >      TabIndex        =   1
43        Text            =   "nettest.frx":0000
44        Top             =   3000
45        Width           =   5055
46     End
47 <   Begin VB.CommandButton Command2
48 <      Caption         =   "TCP to FilterManager"
49 <      Height          =   375
50 <      Left            =   3360
51 <      TabIndex        =   1
52 <      Top             =   2040
53 <      Width           =   1935
47 >   Begin VB.CommandButton Reconfigure
48 >      Caption         =   "Reconfigure with FilterManager"
49 >      Height          =   495
50 >      Left            =   120
51 >      TabIndex        =   0
52 >      Top             =   120
53 >      Width           =   2895
54     End
55     Begin MSWinsockLib.Winsock TCPSock
56 <      Left            =   4920
57 <      Top             =   120
56 >      Left            =   5160
57 >      Top             =   1200
58        _ExtentX        =   741
59        _ExtentY        =   741
60        _Version        =   393216
61     End
58   Begin VB.CommandButton Command1
59      Caption         =   "Send UDP"
60      Height          =   375
61      Left            =   4320
62      TabIndex        =   0
63      Top             =   1560
64      Width           =   975
65   End
62     Begin MSWinsockLib.Winsock UDPSock
63 <      Left            =   4320
64 <      Top             =   120
63 >      Left            =   4680
64 >      Top             =   1200
65        _ExtentX        =   741
66        _ExtentY        =   741
67        _Version        =   393216
68        Protocol        =   1
69     End
70     Begin VB.Label Label2
71 <      Caption         =   "Label2"
71 >      Alignment       =   1  'Right Justify
72 >      Caption         =   "Next heartbeat:"
73        Height          =   255
74 <      Left            =   120
74 >      Left            =   3360
75        TabIndex        =   6
76 <      Top             =   600
77 <      Width           =   3375
76 >      Top             =   480
77 >      Width           =   1455
78     End
79     Begin VB.Label Label1
80 <      Caption         =   "Label1"
80 >      Alignment       =   1  'Right Justify
81 >      Caption         =   "Next UDP packet:"
82        Height          =   255
83 <      Left            =   120
83 >      Left            =   3360
84        TabIndex        =   5
85 <      Top             =   240
86 <      Width           =   3375
85 >      Top             =   120
86 >      Width           =   1455
87     End
88 +   Begin VB.Label Label4
89 +      BorderStyle     =   1  'Fixed Single
90 +      Caption         =   "0"
91 +      Height          =   255
92 +      Left            =   4920
93 +      TabIndex        =   4
94 +      Top             =   480
95 +      Width           =   615
96 +   End
97 +   Begin VB.Label Label3
98 +      BorderStyle     =   1  'Fixed Single
99 +      Caption         =   "0"
100 +      Height          =   255
101 +      Left            =   4920
102 +      TabIndex        =   3
103 +      Top             =   120
104 +      Width           =   615
105 +   End
106     Begin VB.Label Status
107        Caption         =   "Status:"
108        Height          =   255
109        Left            =   120
110 <      TabIndex        =   4
111 <      Top             =   5280
110 >      TabIndex        =   2
111 >      Top             =   840
112        Width           =   5415
113     End
114   End
# Line 134 | Line 150 | Private Sub Command1_Click()
150  
151   End Sub
152  
137 Private Sub Command2_Click()
138    
139    ' establish a TCP connection to a filtermanager
140    TCPSock.Close
141    TCPSock.Connect filterManagerHostname, filterManagerTCPPort
153  
143 End Sub
144
154   Private Sub Command3_Click()
155      ' establish a TCP connection to a filter
156      TCPSock.Close
# Line 150 | Line 159 | End Sub
159  
160   Private Sub Form_Load()
161      protocolVersion = "1.1"
162 +      
163 +    Status.Caption = "Loading"
164 +    Form1.Caption = "i-scream Winhost " & protocolVersion
165      
154    Status.Caption = "i-scream Winhost " & protocolVersion
155    
166      ''''TEMP
167      filterManagerHostname = "killigrew.ukc.ac.uk"
168      filterManagerTCPPort = 4567
169 +    Reconfigure_Click
170      Exit Sub
171      ''' ENDTEMP
172      
# Line 167 | Line 178 | Private Sub Form_Load()
178      length = GetPrivateProfileString("i-scream Winhost", "FilterManagerPort", "<no value>", buf, Len(buf), App.Path & "winhost.ini")
179      filterManagerTCPPort = Left$(buf, length)
180      
181 <    Status.Caption = "i-scream Winhost " & protocolVersion & " connecting to Filter Manager"
181 >    Status.Caption = "Connecting to Filter Manager"
182      
183      Exit Sub
184      
# Line 177 | Line 188 | iniError:
188      
189   End Sub
190  
191 + Private Sub Form_QueryUnload(Cancel As Integer, UnloadMode As Integer)
192 +    x = MsgBox("Are you sure you want to shut down the Winhost?  This will stop your computer sending information to the i-scream Central Monitoring System.", vbYesNo, "i-scream Winhost")
193 +    If x = 7 Then
194 +        Cancel = True
195 +    End If
196 +
197 + End Sub
198 +
199 + Private Sub Hide_Click()
200 +    Form1.Visible = False
201 +    SystemTray.Icon = Val(Form1.Icon)
202 +    SystemTray.Action = 0
203 + End Sub
204 +
205 + Private Sub Reconfigure_Click()
206 +    ' establish a TCP connection to a filtermanager
207 +    connected = False
208 +    TCPSock.Close
209 +    TCPSock.Connect filterManagerHostname, filterManagerTCPPort
210 + End Sub
211 +
212 +
213 +
214 + Private Sub SystemTray_MouseDblClk(ByVal Button As Integer)
215 +
216 +    Form1.Visible = True
217 +    Form1.SetFocus
218 +
219 + End Sub
220 +
221   Private Sub TCPSock_Connect()
222      
223      responseNumber = 0
# Line 250 | Line 291 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
291                  responseNumber = 0
292                  TCPSock.Close
293                  Text4.Text = Text4.Text & vbCrLf & "  <closed>"
294 <                Label1.Caption = "TCP hearbeat interval: " & UDPUpdateTime
295 <                Label2.Caption = "UDP packet interval: " & TCPUpdateTime
296 <                Status.Caption = "i-scream Winhost " & protocolVersion & " - got config okay"
294 >                Status.Caption = "Configuration successful"
295 >                Label3.Caption = UDPUpdateTime
296 >                Label4.Caption = TCPUpdateTime
297 >                Timer1.Interval = 1000
298          End Select
299      Else
300          ' Perform a heartbeat (1.1)
# Line 273 | Line 315 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
315              Case 5:
316                  If Not response = "OK" Then GoTo heartbeatError
317                  TCPSock.Close
318 <                Status.Caption = "i-scream Winhost " & protocolVersion & " - heartbeat sent okay."
318 >                Status.Caption = "Heartbeat sent successfully."
319          End Select
320      
321      End If
# Line 282 | Line 324 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
324      Exit Sub
325      
326   configError:
327 <    Status.Caption = "i-scream Winhost " & protocolVersion & " - FAILED to get configuration"
327 >    Status.Caption = "FAILED to get configuration"
328 >    Exit Sub
329   heartbeatError:
330 <    Status.Caption = "i-scream Winhost " & protocolVersion & " - Heatbeat FAILED"
330 >    Status.Caption = "Heatbeat FAILED"
331 >    Exit Sub
332   End Sub
333  
334 + Private Sub Timer1_Timer()
335 +
336 +    Label3.Caption = Label3.Caption - 1
337 +    Label4.Caption = Label4.Caption - 1
338 +    
339 +    Status.Caption = ""
340 +    
341 +    If Label3.Caption < 1 Then
342 +        ' build the contents of the XML packet.
343 +        xml = "<packet></packet>"
344 +
345 +        ' Use the first winsock control to send a UDP packet.
346 +        UDPSock.RemoteHost = filterHostname
347 +        UDPSock.RemotePort = filterUDPPort
348 +        UDPSock.SendData xml
349 +        Status.Caption = "UDP packet sent"
350 +        Label3.Caption = UDPUpdateTime
351 +    End If
352 +    
353 +    If Label4.Caption < 1 Then
354 +        ' establish a TCP connection to a filter
355 +        TCPSock.Close
356 +        TCPSock.Connect filterHostname, filterTCPPort
357 +        Label4.Caption = TCPUpdateTime
358 +    End If
359 +
360 + End Sub

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines