--- experimental/host/vb_net_test/nettest.frm 2001/02/23 11:42:06 1.10
+++ experimental/host/vb_net_test/nettest.frm 2001/02/23 13:27:09 1.14
@@ -1,22 +1,38 @@
VERSION 5.00
Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX"
+Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0"; "SysTray.ocx"
Begin VB.Form Form1
BorderStyle = 4 'Fixed ToolWindow
Caption = "i-scream Winhost"
ClientHeight = 5655
ClientLeft = 45
ClientTop = 285
- ClientWidth = 5670
+ ClientWidth = 4710
LinkTopic = "Form1"
MaxButton = 0 'False
- MinButton = 0 'False
ScaleHeight = 5655
- ScaleWidth = 5670
+ ScaleWidth = 4710
ShowInTaskbar = 0 'False
StartUpPosition = 3 'Windows Default
+ Begin VB.CommandButton Hide
+ Caption = "Hide Window"
+ Height = 375
+ Left = 3120
+ TabIndex = 7
+ Top = 840
+ Width = 1455
+ End
+ Begin SysTray.SystemTray SystemTray
+ Left = 2160
+ Top = 1800
+ _ExtentX = 847
+ _ExtentY = 847
+ SysTrayText = "i-scream Winhost"
+ IconFile = 0
+ End
Begin VB.Timer Timer1
- Left = 4200
- Top = 1200
+ Left = 2760
+ Top = 1800
End
Begin VB.TextBox Text4
Height = 1575
@@ -26,26 +42,26 @@ Begin VB.Form Form1
TabIndex = 1
Text = "nettest.frx":0000
Top = 3000
- Width = 5055
+ Width = 3975
End
Begin VB.CommandButton Reconfigure
Caption = "Reconfigure with FilterManager"
- Height = 495
+ Height = 375
Left = 120
TabIndex = 0
- Top = 120
+ Top = 840
Width = 2895
End
Begin MSWinsockLib.Winsock TCPSock
- Left = 5160
- Top = 1200
+ Left = 3720
+ Top = 1800
_ExtentX = 741
_ExtentY = 741
_Version = 393216
End
Begin MSWinsockLib.Winsock UDPSock
- Left = 4680
- Top = 1200
+ Left = 3240
+ Top = 1800
_ExtentX = 741
_ExtentY = 741
_Version = 393216
@@ -55,7 +71,7 @@ Begin VB.Form Form1
Alignment = 1 'Right Justify
Caption = "Next heartbeat:"
Height = 255
- Left = 3360
+ Left = 2400
TabIndex = 6
Top = 480
Width = 1455
@@ -64,7 +80,7 @@ Begin VB.Form Form1
Alignment = 1 'Right Justify
Caption = "Next UDP packet:"
Height = 255
- Left = 3360
+ Left = 2400
TabIndex = 5
Top = 120
Width = 1455
@@ -73,7 +89,7 @@ Begin VB.Form Form1
BorderStyle = 1 'Fixed Single
Caption = "0"
Height = 255
- Left = 4920
+ Left = 3960
TabIndex = 4
Top = 480
Width = 615
@@ -82,18 +98,19 @@ Begin VB.Form Form1
BorderStyle = 1 'Fixed Single
Caption = "0"
Height = 255
- Left = 4920
+ Left = 3960
TabIndex = 3
Top = 120
Width = 615
End
Begin VB.Label Status
+ Alignment = 2 'Center
Caption = "Status:"
Height = 255
Left = 120
TabIndex = 2
- Top = 840
- Width = 5415
+ Top = 1320
+ Width = 4455
End
End
Attribute VB_Name = "Form1"
@@ -107,6 +124,9 @@ Private Declare Function GetPrivateProfileInt Lib "ker
Dim filterManagerHostname As String
Dim filterManagerTCPPort As Integer
+Dim seqNo As Long
+Dim machineName As String
+
Dim filterHostname As String
Dim filterTCPPort As Integer
Dim filterUDPPort As Integer
@@ -120,40 +140,19 @@ Dim protocolVersion As String
Dim connected As Boolean
Dim responseNumber As Integer
-
-Private Sub Command1_Click()
-
- ' build the contents of the XML packet.
- xml = ""
-
- ' Use the first winsock control to send a UDP packet.
- UDPSock.RemoteHost = filterHostname
- UDPSock.RemotePort = filterUDPPort
- UDPSock.SendData xml
- Status.Caption = "i-scream Winhost " & protocolVersion & " - UDP packet sent."
-
-End Sub
-
-
-Private Sub Command3_Click()
- ' establish a TCP connection to a filter
- TCPSock.Close
- TCPSock.Connect filterHostname, filterTCPPort
-End Sub
-
Private Sub Form_Load()
+
protocolVersion = "1.1"
-
+
Status.Caption = "Loading"
Form1.Caption = "i-scream Winhost " & protocolVersion
''''TEMP
filterManagerHostname = "killigrew.ukc.ac.uk"
filterManagerTCPPort = 4567
- Reconfigure_Click
- Exit Sub
- ''' ENDTEMP
+ ''''' END TEMP
+ GoTo skip
On Error GoTo iniError
Dim buf As String * 256
Dim length As Long
@@ -161,8 +160,10 @@ Private Sub Form_Load()
filterManagerHostname = Left$(buf, length)
length = GetPrivateProfileString("i-scream Winhost", "FilterManagerPort", "", buf, Len(buf), App.Path & "winhost.ini")
filterManagerTCPPort = Left$(buf, length)
-
+skip:
+
Status.Caption = "Connecting to Filter Manager"
+ Reconfigure_Click
Exit Sub
@@ -173,13 +174,20 @@ iniError:
End Sub
Private Sub Form_QueryUnload(Cancel As Integer, UnloadMode As Integer)
- x = MsgBox("Are you sure you want to shut down the Winhost?", vbYesNo, "i-scream Winhost")
+ x = MsgBox("Are you sure you want to shut down the Winhost? This will stop your computer sending information to the i-scream Central Monitoring System.", vbYesNo, "i-scream Winhost")
If x = 7 Then
Cancel = True
End If
+ SystemTray.Action = 2
End Sub
+Private Sub Hide_Click()
+ Form1.Visible = False
+ SystemTray.Icon = Val(Form1.Icon)
+ SystemTray.Action = 0
+End Sub
+
Private Sub Reconfigure_Click()
' establish a TCP connection to a filtermanager
connected = False
@@ -187,6 +195,17 @@ Private Sub Reconfigure_Click()
TCPSock.Connect filterManagerHostname, filterManagerTCPPort
End Sub
+
+
+Private Sub SystemTray_MouseDblClk(ByVal Button As Integer)
+
+ Form1.Visible = True
+ SystemTray.Action = 2
+ Form1.SetFocus
+
+
+End Sub
+
Private Sub TCPSock_Connect()
responseNumber = 0
@@ -309,7 +328,27 @@ Private Sub Timer1_Timer()
If Label3.Caption < 1 Then
' build the contents of the XML packet.
- xml = ""
+ localIP = TCPSock.localIP
+ machineName = TCPSock.LocalHostName
+ seqNo = seqNo + 1
+ packetDate = Date2Num()
+ xml = "" & _
+ "" & _
+ "" & _
+ "" & _
+ "" & _
+ "" & _
+ "" & _
+ "" & _
+ "" & _
+ "" & _
+ "" & _
+ "" & _
+ "" & _
+ "" & _
+ "" & _
+ ""
+ Text4.Text = Text4.Text + xml
' Use the first winsock control to send a UDP packet.
UDPSock.RemoteHost = filterHostname
@@ -327,3 +366,9 @@ Private Sub Timer1_Timer()
End If
End Sub
+
+Function Date2Num() As Long
+ Dim x As Long
+ x = DateDiff("s", "1-1-1970", Now)
+ Date2Num = x
+End Function