ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/experimental/host/vb_net_test/nettest.frm
(Generate patch)

Comparing experimental/host/vb_net_test/nettest.frm (file contents):
Revision 1.3 by pjm2, Fri Feb 23 10:07:55 2001 UTC vs.
Revision 1.14 by pjm2, Fri Feb 23 13:27:09 2001 UTC

# Line 1 | Line 1
1   VERSION 5.00
2   Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX"
3 + Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0"; "SysTray.ocx"
4   Begin VB.Form Form1
5 <   BorderStyle     =   3  'Fixed Dialog
6 <   Caption         =   "TCP/UDP Test program"
5 >   BorderStyle     =   4  'Fixed ToolWindow
6 >   Caption         =   "i-scream Winhost"
7     ClientHeight    =   5655
8     ClientLeft      =   45
9 <   ClientTop       =   330
10 <   ClientWidth     =   5670
9 >   ClientTop       =   285
10 >   ClientWidth     =   4710
11     LinkTopic       =   "Form1"
12     MaxButton       =   0   'False
12   MinButton       =   0   'False
13     ScaleHeight     =   5655
14 <   ScaleWidth      =   5670
14 >   ScaleWidth      =   4710
15     ShowInTaskbar   =   0   'False
16     StartUpPosition =   3  'Windows Default
17 <   Begin VB.CommandButton Command3
18 <      Caption         =   "TCP to Filter"
17 >   Begin VB.CommandButton Hide
18 >      Caption         =   "Hide Window"
19        Height          =   375
20 <      Left            =   3720
21 <      TabIndex        =   9
22 <      Top             =   2520
23 <      Width           =   1575
20 >      Left            =   3120
21 >      TabIndex        =   7
22 >      Top             =   840
23 >      Width           =   1455
24     End
25 +   Begin SysTray.SystemTray SystemTray
26 +      Left            =   2160
27 +      Top             =   1800
28 +      _ExtentX        =   847
29 +      _ExtentY        =   847
30 +      SysTrayText     =   "i-scream Winhost"
31 +      IconFile        =   0
32 +   End
33 +   Begin VB.Timer Timer1
34 +      Left            =   2760
35 +      Top             =   1800
36 +   End
37     Begin VB.TextBox Text4
38 <      Height          =   2535
38 >      Height          =   1575
39        Left            =   240
40        MultiLine       =   -1  'True
41        ScrollBars      =   2  'Vertical
42 <      TabIndex        =   8
42 >      TabIndex        =   1
43        Text            =   "nettest.frx":0000
44        Top             =   3000
45 <      Width           =   5055
45 >      Width           =   3975
46     End
47 <   Begin VB.CommandButton Command2
48 <      Caption         =   "TCP to FilterManager"
47 >   Begin VB.CommandButton Reconfigure
48 >      Caption         =   "Reconfigure with FilterManager"
49        Height          =   375
50 <      Left            =   3360
51 <      TabIndex        =   7
52 <      Top             =   2040
53 <      Width           =   1935
50 >      Left            =   120
51 >      TabIndex        =   0
52 >      Top             =   840
53 >      Width           =   2895
54     End
55 <   Begin MSWinsockLib.Winsock Winsock2
56 <      Left            =   4920
57 <      Top             =   120
55 >   Begin MSWinsockLib.Winsock TCPSock
56 >      Left            =   3720
57 >      Top             =   1800
58        _ExtentX        =   741
59        _ExtentY        =   741
60        _Version        =   393216
61     End
62 <   Begin VB.TextBox Text3
63 <      Height          =   285
64 <      Left            =   1680
53 <      TabIndex        =   5
54 <      Text            =   "killigrew.ukc.ac.uk"
55 <      Top             =   1560
56 <      Width           =   2535
57 <   End
58 <   Begin VB.TextBox Text2
59 <      Height          =   285
60 <      Left            =   1680
61 <      TabIndex        =   3
62 <      Text            =   "4567"
63 <      Top             =   1920
64 <      Width           =   855
65 <   End
66 <   Begin VB.CommandButton Command1
67 <      Caption         =   "Send UDP"
68 <      Height          =   375
69 <      Left            =   4320
70 <      TabIndex        =   2
71 <      Top             =   1560
72 <      Width           =   975
73 <   End
74 <   Begin VB.TextBox Text1
75 <      Height          =   855
76 <      Left            =   360
77 <      TabIndex        =   0
78 <      Text            =   "<packet></packet>"
79 <      Top             =   600
80 <      Width           =   4935
81 <   End
82 <   Begin MSWinsockLib.Winsock Winsock1
83 <      Left            =   4320
84 <      Top             =   120
62 >   Begin MSWinsockLib.Winsock UDPSock
63 >      Left            =   3240
64 >      Top             =   1800
65        _ExtentX        =   741
66        _ExtentY        =   741
67        _Version        =   393216
68        Protocol        =   1
69     End
70 <   Begin VB.Label Label3
70 >   Begin VB.Label Label2
71        Alignment       =   1  'Right Justify
72 <      Caption         =   "Destination:"
72 >      Caption         =   "Next heartbeat:"
73        Height          =   255
74 <      Left            =   360
74 >      Left            =   2400
75        TabIndex        =   6
76 <      Top             =   1560
77 <      Width           =   1215
76 >      Top             =   480
77 >      Width           =   1455
78     End
79 <   Begin VB.Label Label2
79 >   Begin VB.Label Label1
80        Alignment       =   1  'Right Justify
81 <      Caption         =   "Port:"
81 >      Caption         =   "Next UDP packet:"
82        Height          =   255
83 <      Left            =   360
83 >      Left            =   2400
84 >      TabIndex        =   5
85 >      Top             =   120
86 >      Width           =   1455
87 >   End
88 >   Begin VB.Label Label4
89 >      BorderStyle     =   1  'Fixed Single
90 >      Caption         =   "0"
91 >      Height          =   255
92 >      Left            =   3960
93        TabIndex        =   4
94 <      Top             =   1920
95 <      Width           =   1215
94 >      Top             =   480
95 >      Width           =   615
96     End
97 <   Begin VB.Label Label1
98 <      Caption         =   "Packet contents"
97 >   Begin VB.Label Label3
98 >      BorderStyle     =   1  'Fixed Single
99 >      Caption         =   "0"
100        Height          =   255
101 <      Left            =   360
102 <      TabIndex        =   1
103 <      Top             =   360
104 <      Width           =   2895
101 >      Left            =   3960
102 >      TabIndex        =   3
103 >      Top             =   120
104 >      Width           =   615
105     End
106 +   Begin VB.Label Status
107 +      Alignment       =   2  'Center
108 +      Caption         =   "Status:"
109 +      Height          =   255
110 +      Left            =   120
111 +      TabIndex        =   2
112 +      Top             =   1320
113 +      Width           =   4455
114 +   End
115   End
116   Attribute VB_Name = "Form1"
117   Attribute VB_GlobalNameSpace = False
118   Attribute VB_Creatable = False
119   Attribute VB_PredeclaredId = True
120   Attribute VB_Exposed = False
121 + Private Declare Function GetPrivateProfileString Lib "kernel32" Alias "GetPrivateProfileStringA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal lpDefault As String, ByVal lpReturnedString As String, ByVal nSize As Long, ByVal lpFileName As String) As Long
122 + Private Declare Function GetPrivateProfileInt Lib "kernel32" Alias "GetPrivateProfileIntA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal nDefault As Long, ByVal lpFileName As String) As Long
123 +
124 + Dim filterManagerHostname As String
125 + Dim filterManagerTCPPort As Integer
126 +
127 + Dim seqNo As Long
128 + Dim machineName As String
129 +
130   Dim filterHostname As String
131   Dim filterTCPPort As Integer
132   Dim filterUDPPort As Integer
133   Dim fileList As String
134   Dim lastModified As String
135  
136 + Dim UDPUpdateTime As Integer
137 + Dim TCPUpdateTime As Integer
138 +
139   Dim protocolVersion As String
140   Dim connected As Boolean
141   Dim responseNumber As Integer
142  
143 + Private Sub Form_Load()
144 +    
145 +    protocolVersion = "1.1"
146 +    
147 +    Status.Caption = "Loading"
148 +    Form1.Caption = "i-scream Winhost " & protocolVersion
149 +    
150 +    ''''TEMP
151 +    filterManagerHostname = "killigrew.ukc.ac.uk"
152 +    filterManagerTCPPort = 4567
153 +    ''''' END TEMP
154 +    
155 +    GoTo skip
156 +    On Error GoTo iniError
157 +    Dim buf As String * 256
158 +    Dim length As Long
159 +    length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "<no value>", buf, Len(buf), App.Path & "winhost.ini")
160 +    filterManagerHostname = Left$(buf, length)
161 +    length = GetPrivateProfileString("i-scream Winhost", "FilterManagerPort", "<no value>", buf, Len(buf), App.Path & "winhost.ini")
162 +    filterManagerTCPPort = Left$(buf, length)
163 + skip:
164  
165 < Private Sub Command1_Click()
165 >    Status.Caption = "Connecting to Filter Manager"
166 >    Reconfigure_Click
167 >    
168 >    Exit Sub
169 >    
170 > iniError:
171 >    x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file.  Please correct these and try again.", 48, "Configuration not found")
172 >    End
173 >    
174 > End Sub
175  
176 <    ' Use the first winsock control to send a UDP packet.
177 <    Winsock1.RemoteHost = Text3.Text
178 <    Winsock1.RemotePort = Text2.Text
179 <    Winsock1.SendData Text1.Text
176 > Private Sub Form_QueryUnload(Cancel As Integer, UnloadMode As Integer)
177 >    x = MsgBox("Are you sure you want to shut down the Winhost?  This will stop your computer sending information to the i-scream Central Monitoring System.", vbYesNo, "i-scream Winhost")
178 >    If x = 7 Then
179 >        Cancel = True
180 >    End If
181 >    SystemTray.Action = 2
182  
183   End Sub
184  
185 < Private Sub Command2_Click()
186 <    
187 <    ' establish a TCP connection to a filtermanager
188 <    Winsock2.Close
146 <    Winsock2.Connect Text3.Text, Text2.Text
147 <
185 > Private Sub Hide_Click()
186 >    Form1.Visible = False
187 >    SystemTray.Icon = Val(Form1.Icon)
188 >    SystemTray.Action = 0
189   End Sub
190  
191 < Private Sub Command3_Click()
192 <    ' establish a TCP connection to a filter
193 <    Winsock2.Close
194 <    Winsock2.Connect filterHostname, filterTCPPort
191 > Private Sub Reconfigure_Click()
192 >    ' establish a TCP connection to a filtermanager
193 >    connected = False
194 >    TCPSock.Close
195 >    TCPSock.Connect filterManagerHostname, filterManagerTCPPort
196   End Sub
197  
198 < Private Sub Form_Load()
199 <    protocolVersion = "1.1"
198 >
199 >
200 > Private Sub SystemTray_MouseDblClk(ByVal Button As Integer)
201 >
202 >    Form1.Visible = True
203 >    SystemTray.Action = 2
204 >    Form1.SetFocus
205 >    
206 >
207   End Sub
208  
209 < Private Sub Winsock2_Connect()
210 <      
211 <   responseNumber = 0
209 > Private Sub TCPSock_Connect()
210 >    
211 >    responseNumber = 0
212    
213      ' Send something as soon as we connect to the server.
214      If connected = False Then
215          ' contact the FilterManager
216 <        Winsock2.SendData "STARTCONFIG" & vbCrLf
216 >        TCPSock.SendData "STARTCONFIG" & vbCrLf
217      Else
218         ' Contact the Filter
219 <       Winsock2.SendData "HEARTBEAT" & vbCrLf
219 >       TCPSock.SendData "HEARTBEAT" & vbCrLf
220      End If
221    
222   End Sub
223  
224 < Private Sub Winsock2_DataArrival(ByVal bytesTotal As Long)
224 > Private Sub TCPSock_DataArrival(ByVal bytesTotal As Long)
225      
226      responseNumber = responseNumber + 1
227      
228      ' Get the line from the server.
229 <    Winsock2.GetData response, vbString, bytesTotal
229 >    TCPSock.GetData response, vbString, bytesTotal
230      
231      ' Remove linefeeds and returns from the line.
232      response = Replace(response, Chr(13), "")
# Line 190 | Line 239 | Private Sub Winsock2_DataArrival(ByVal bytesTotal As L
239          Select Case responseNumber
240              Case 1:
241                  If Not response = "OK" Then GoTo configError
242 <                Winsock2.SendData "LASTMODIFIED" & vbCrLf
242 >                TCPSock.SendData "LASTMODIFIED" & vbCrLf
243              Case 2:
244                  If response = "ERROR" Then GoTo configError
245                  lastModified = response
246 <                Winsock2.SendData "FILELIST" & vbCrLf
246 >                TCPSock.SendData "FILELIST" & vbCrLf
247              Case 3:
248                  If response = "ERROR" Then GoTo configError
249                  fileList = response
250 <                Winsock2.SendData "UDPUpdateTime" & vbCrLf
250 >                TCPSock.SendData "UDPUpdateTime" & vbCrLf
251              Case 4:
252                  If response = "ERROR" Then GoTo configError
253 <                Winsock2.SendData "TCPUpdateTime" & vbCrLf
253 >                UDPUpdateTime = response
254 >                TCPSock.SendData "TCPUpdateTime" & vbCrLf
255              Case 5:
256                  If response = "ERROR" Then GoTo configError
257 <                Winsock2.SendData "ENDCONFIG" & vbCrLf
257 >                TCPUpdateTime = response
258 >                TCPSock.SendData "ENDCONFIG" & vbCrLf
259              Case 6:
260                  If Not response = "OK" Then GoTo configError
261 <                Winsock2.SendData "FILTER" & vbCrLf
261 >                TCPSock.SendData "FILTER" & vbCrLf
262              Case 7:
263                  'we got a filter list here.
264                  readTo = 0
# Line 221 | Line 272 | Private Sub Winsock2_DataArrival(ByVal bytesTotal As L
272                  response = Mid(response, readTo + 1, Len(response))
273                  ' get TCP Port number
274                  filterTCPPort = response
275 <                Winsock2.SendData "END" & vbCrLf
275 >                TCPSock.SendData "END" & vbCrLf
276              Case 8:
277                  If Not response = "OK" Then GoTo configError
278                  connected = True
279                  responseNumber = 0
280 <                Winsock2.Close
280 >                TCPSock.Close
281                  Text4.Text = Text4.Text & vbCrLf & "  <closed>"
282 <                x = MsgBox("got config okay")
282 >                Status.Caption = "Configuration successful"
283 >                Label3.Caption = UDPUpdateTime
284 >                Label4.Caption = TCPUpdateTime
285 >                Timer1.Interval = 1000
286          End Select
287      Else
288          ' Perform a heartbeat (1.1)
# Line 236 | Line 290 | Private Sub Winsock2_DataArrival(ByVal bytesTotal As L
290          Select Case responseNumber
291              Case 1:
292                  If Not response = "OK" Then GoTo heartbeatError
293 <                Winsock2.SendData "CONFIG" & vbCrLf
293 >                TCPSock.SendData "CONFIG" & vbCrLf
294              Case 2:
295                  If Not response = "OK" Then GoTo heartbeatError
296 <                Winsock2.SendData fileList & vbCrLf
296 >                TCPSock.SendData fileList & vbCrLf
297              Case 3:
298                  If Not response = "OK" Then GoTo heartbeatError
299 <                Winsock2.SendData lastModified & vbCrLf
299 >                TCPSock.SendData lastModified & vbCrLf
300              Case 4:
301                  If Not response = "OK" Then GoTo heartbeatError
302 <                Winsock2.SendData "ENDHEARTBEAT" & vbCrLf
302 >                TCPSock.SendData "ENDHEARTBEAT" & vbCrLf
303              Case 5:
304                  If Not response = "OK" Then GoTo heartbeatError
305 <                Winsock2.Close
306 <                x = MsgBox("heartbeat sent okay.")
305 >                TCPSock.Close
306 >                Status.Caption = "Heartbeat sent successfully."
307          End Select
308      
309      End If
# Line 258 | Line 312 | Private Sub Winsock2_DataArrival(ByVal bytesTotal As L
312      Exit Sub
313      
314   configError:
315 <    x = MsgBox("error doing configuration")
315 >    Status.Caption = "FAILED to get configuration"
316 >    Exit Sub
317   heartbeatError:
318 +    Status.Caption = "Heatbeat FAILED"
319 +    Exit Sub
320 + End Sub
321 +
322 + Private Sub Timer1_Timer()
323 +
324 +    Label3.Caption = Label3.Caption - 1
325 +    Label4.Caption = Label4.Caption - 1
326      
327 +    Status.Caption = ""
328 +    
329 +    If Label3.Caption < 1 Then
330 +        ' build the contents of the XML packet.
331 +        localIP = TCPSock.localIP
332 +        machineName = TCPSock.LocalHostName
333 +        seqNo = seqNo + 1
334 +        packetDate = Date2Num()
335 +        xml = "<packet seq_no=""" & seqNo & """ machine_name=""" & machineName & """ date=""" & packetDate & """ type=""data"" ip=""" & localIP & """>" & _
336 +              "" & _
337 +              "" & _
338 +              "" & _
339 +              "" & _
340 +              "" & _
341 +              "" & _
342 +              "" & _
343 +              "" & _
344 +              "" & _
345 +              "" & _
346 +              "" & _
347 +              "" & _
348 +              "" & _
349 +              "" & _
350 +              ""
351 +        Text4.Text = Text4.Text + xml
352 +
353 +        ' Use the first winsock control to send a UDP packet.
354 +        UDPSock.RemoteHost = filterHostname
355 +        UDPSock.RemotePort = filterUDPPort
356 +        UDPSock.SendData xml
357 +        Status.Caption = "UDP packet sent"
358 +        Label3.Caption = UDPUpdateTime
359 +    End If
360 +    
361 +    If Label4.Caption < 1 Then
362 +        ' establish a TCP connection to a filter
363 +        TCPSock.Close
364 +        TCPSock.Connect filterHostname, filterTCPPort
365 +        Label4.Caption = TCPUpdateTime
366 +    End If
367 +
368   End Sub
369 +
370 + Function Date2Num() As Long
371 +    Dim x As Long
372 +    x = DateDiff("s", "1-1-1970", Now)
373 +    Date2Num = x
374 + End Function

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines