ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/experimental/host/vb_net_test/nettest.frm
(Generate patch)

Comparing experimental/host/vb_net_test/nettest.frm (file contents):
Revision 1.17 by pjm2, Fri Feb 23 17:37:04 2001 UTC vs.
Revision 1.29 by pjm2, Wed Feb 28 10:45:37 2001 UTC

# Line 4 | Line 4 | Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0
4   Begin VB.Form Form1
5     BorderStyle     =   3  'Fixed Dialog
6     Caption         =   "i-scream Winhost"
7 <   ClientHeight    =   5655
7 >   ClientHeight    =   1185
8     ClientLeft      =   45
9     ClientTop       =   330
10     ClientWidth     =   4710
11 +   Icon            =   "nettest.frx":0000
12     LinkTopic       =   "Form1"
13     MaxButton       =   0   'False
14     MinButton       =   0   'False
15 <   ScaleHeight     =   5655
15 >   ScaleHeight     =   1185
16     ScaleWidth      =   4710
17     ShowInTaskbar   =   0   'False
18 <   StartUpPosition =   3  'Windows Default
19 <   Begin VB.CommandButton Hide
20 <      Caption         =   "Hide Window"
21 <      Height          =   375
22 <      Left            =   3120
23 <      TabIndex        =   7
18 >   StartUpPosition =   2  'CenterScreen
19 >   Visible         =   0   'False
20 >   Begin VB.CommandButton Command1
21 >      Caption         =   "more"
22 >      Height          =   255
23 >      Left            =   3960
24 >      TabIndex        =   8
25        Top             =   840
26 <      Width           =   1455
26 >      Width           =   615
27     End
28 +   Begin VB.TextBox Text1
29 +      Height          =   2055
30 +      Left            =   120
31 +      Locked          =   -1  'True
32 +      MultiLine       =   -1  'True
33 +      ScrollBars      =   2  'Vertical
34 +      TabIndex        =   7
35 +      Top             =   1200
36 +      Width           =   4455
37 +   End
38 +   Begin VB.CommandButton Hide
39 +      Caption         =   "hide"
40 +      Height          =   255
41 +      Left            =   3960
42 +      TabIndex        =   6
43 +      Top             =   480
44 +      Width           =   615
45 +   End
46     Begin SysTray.SystemTray SystemTray
47 <      Left            =   2160
48 <      Top             =   1800
47 >      Left            =   2520
48 >      Top             =   4200
49        _ExtentX        =   847
50        _ExtentY        =   847
51        SysTrayText     =   "i-scream Winhost"
52        IconFile        =   0
53     End
54     Begin VB.Timer Timer1
55 <      Left            =   2760
56 <      Top             =   1800
55 >      Left            =   3120
56 >      Top             =   4200
57     End
38   Begin VB.TextBox Text4
39      Height          =   1575
40      Left            =   240
41      MultiLine       =   -1  'True
42      ScrollBars      =   2  'Vertical
43      TabIndex        =   1
44      Text            =   "nettest.frx":0000
45      Top             =   3000
46      Width           =   3975
47   End
58     Begin VB.CommandButton Reconfigure
59        Caption         =   "Reconfigure with FilterManager"
60        Height          =   375
61 <      Left            =   120
61 >      Left            =   840
62        TabIndex        =   0
63 <      Top             =   840
63 >      Top             =   3480
64        Width           =   2895
65     End
66     Begin MSWinsockLib.Winsock TCPSock
67 <      Left            =   3720
68 <      Top             =   1800
67 >      Left            =   4080
68 >      Top             =   4200
69        _ExtentX        =   741
70        _ExtentY        =   741
71        _Version        =   393216
72     End
73     Begin MSWinsockLib.Winsock UDPSock
74 <      Left            =   3240
75 <      Top             =   1800
74 >      Left            =   3600
75 >      Top             =   4200
76        _ExtentX        =   741
77        _ExtentY        =   741
78        _Version        =   393216
79        Protocol        =   1
80     End
71   Begin VB.Label Label5
72      Caption         =   "b e t a"
73      BeginProperty Font
74         Name            =   "MS Sans Serif"
75         Size            =   24
76         Charset         =   0
77         Weight          =   700
78         Underline       =   0   'False
79         Italic          =   0   'False
80         Strikethrough   =   0   'False
81      EndProperty
82      Height          =   615
83      Left            =   240
84      TabIndex        =   8
85      Top             =   120
86      Width           =   1815
87   End
81     Begin VB.Label Label2
82        Alignment       =   1  'Right Justify
83        Caption         =   "Next heartbeat:"
84        Height          =   255
85 <      Left            =   2400
86 <      TabIndex        =   6
85 >      Left            =   120
86 >      TabIndex        =   5
87        Top             =   480
88        Width           =   1455
89     End
# Line 98 | Line 91 | Begin VB.Form Form1
91        Alignment       =   1  'Right Justify
92        Caption         =   "Next UDP packet:"
93        Height          =   255
94 <      Left            =   2400
95 <      TabIndex        =   5
94 >      Left            =   120
95 >      TabIndex        =   4
96        Top             =   120
97        Width           =   1455
98     End
# Line 107 | Line 100 | Begin VB.Form Form1
100        BorderStyle     =   1  'Fixed Single
101        Caption         =   "0"
102        Height          =   255
103 <      Left            =   3960
104 <      TabIndex        =   4
103 >      Left            =   1680
104 >      TabIndex        =   3
105        Top             =   480
106        Width           =   615
107     End
# Line 116 | Line 109 | Begin VB.Form Form1
109        BorderStyle     =   1  'Fixed Single
110        Caption         =   "0"
111        Height          =   255
112 <      Left            =   3960
113 <      TabIndex        =   3
112 >      Left            =   1680
113 >      TabIndex        =   2
114        Top             =   120
115        Width           =   615
116     End
# Line 125 | Line 118 | Begin VB.Form Form1
118        Alignment       =   2  'Center
119        Caption         =   "Status:"
120        Height          =   255
121 <      Left            =   120
122 <      TabIndex        =   2
123 <      Top             =   1320
124 <      Width           =   4455
121 >      Left            =   0
122 >      TabIndex        =   1
123 >      Top             =   840
124 >      Width           =   3855
125     End
126   End
127   Attribute VB_Name = "Form1"
# Line 141 | Line 134 | Private Declare Function GetPrivateProfileString Lib "
134   Private Declare Function GetPrivateProfileInt Lib "kernel32" Alias "GetPrivateProfileIntA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal nDefault As Long, ByVal lpFileName As String) As Long
135  
136   Dim filterManagerHostname As String
137 < Dim filterManagerTCPPort As Integer
137 > Dim filterManagerTCPPort As Long
138  
139   Dim seqNo As Long
140   Dim machineName As String
# Line 158 | Line 151 | Dim TCPUpdateTime As Integer
151   Dim protocolVersion As String
152   Dim connected As Boolean
153  
154 < 'Dim CUpTime As New CUpTime
154 > Dim CUpTime As New CUpTime
155 > Dim wksta As New CNetWksta
156  
157 + Dim windowBig As Boolean
158 +
159   Dim responseNumber As Integer
160  
161 + Private Sub Command1_Click()
162 +
163 +    ' Toggle visibility of the debug output.
164 +
165 +    If windowBig Then
166 +        Form1.Height = 1500
167 +        windowBig = False
168 +    Else
169 +        Form1.Height = 4350
170 +        windowBig = True
171 +    End If
172 +
173 + End Sub
174 +
175   Private Sub Form_Load()
176      
177 +    If App.PrevInstance Then
178 +        x = MsgBox("There is already an i-scream Winhost running on this machine.", 48, "i-scream host already running")
179 +        End
180 +    End If
181 +    
182      protocolVersion = "1.1"
183      
184      Status.Caption = "Loading"
185 <    'Form1.Caption = "i-scream Winhost " & protocolVersion & " for " & GetVersion()
185 >    Form1.Caption = "i-scream Winhost " & protocolVersion
186      
187 +    CUpTime.Init
188 +    
189 +    If CUpTime.isWin9x Then
190 +        x = MsgBox("Sorry, the i-scream host can only be used to monitor servers (i.e. not Win9x)", 48, "Not a server")
191 +        End
192 +    End If
193 +    
194 +    windowBig = False
195 +    
196      ''''TEMP
197 <    filterManagerHostname = "killigrew.ukc.ac.uk"
198 <    filterManagerTCPPort = 4567
197 >    'filterManagerHostname = "killigrew.ukc.ac.uk"
198 >    'filterManagerTCPPort = 4567
199      ''''' END TEMP
200      
201 <    GoTo skip
201 >    'GoTo skip
202      On Error GoTo iniError
203      Dim buf As String * 256
204      Dim length As Long
205 <    length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "<no value>", buf, Len(buf), App.Path & "winhost.ini")
205 >    length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "<no value>", buf, Len(buf), App.Path & "/winhost.ini")
206      filterManagerHostname = Left$(buf, length)
207 <    length = GetPrivateProfileString("i-scream Winhost", "FilterManagerPort", "<no value>", buf, Len(buf), App.Path & "winhost.ini")
208 <    filterManagerTCPPort = Left$(buf, length)
207 >    length = GetPrivateProfileInt("i-scream Winhost", "FilterManagerPort", 0, App.Path & "/winhost.ini")
208 >    filterManagerTCPPort = length
209 >    If filterManagerHostname = "" Then
210 >        GoTo iniError
211 >    End If
212 >    On Error GoTo 0
213   skip:
214  
215 <    Status.Caption = "Connecting to Filter Manager"
215 >    Status.Caption = "Connecting to Filter Manager " & filterManagerHostname & ":" & filterManagerTCPPort
216      Reconfigure_Click
217      
218 <    Form1.Show
218 >    SystemTray.Icon = Val(Form1.Icon)
219      SystemTray.Action = 0
220      
221      
222      Exit Sub
223      
224   iniError:
225 <    x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file.  Please correct these and try again.", 48, "Configuration not found")
225 >    x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file.  Please correct these and try again.  " & Err.Description, 48, "Configuration not found")
226      End
227      
228   End Sub
# Line 227 | Line 255 | Private Sub SystemTray_MouseDblClk(ByVal Button As Int
255  
256      Form1.Visible = True
257      Form1.SetFocus
230    
258  
259   End Sub
260  
# Line 256 | Line 283 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
283      ' Remove linefeeds and returns from the line.
284      response = Replace(response, Chr(13), "")
285      response = Replace(response, Chr(10), "")
259    Text4.Text = Text4.Text & vbCrLf & response
286      
287      If connected = False Then
288          ' Perform TCP configuration (1.1)
# Line 265 | Line 291 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
291              Case 1:
292                  If Not response = "OK" Then GoTo configError
293                  TCPSock.SendData "LASTMODIFIED" & vbCrLf
294 +                Text1.Text = "Requesting configuration from FilterManager:- " & vbCrLf
295 +                Text1.Text = Text1.Text & response & vbCrLf
296              Case 2:
297                  If response = "ERROR" Then GoTo configError
298                  lastModified = response
299 +                Text1.Text = Text1.Text & response & vbCrLf
300                  TCPSock.SendData "FILELIST" & vbCrLf
301 +            ' New addition to the protocol.
302              Case 3:
303                  If response = "ERROR" Then GoTo configError
304                  fileList = response
305 <                TCPSock.SendData "UDPUpdateTime" & vbCrLf
305 >                Text1.Text = Text1.Text & response & vbCrLf
306 >                TCPSock.SendData "FQDN" & vbCrLf
307              Case 4:
308                  If response = "ERROR" Then GoTo configError
309 +                Text1.Text = Text1.Text & response & vbCrLf
310 +                machineName = response
311 +                TCPSock.SendData "UDPUpdateTime" & vbCrLf
312 +            Case 5:
313 +                If response = "ERROR" Then GoTo configError
314                  UDPUpdateTime = response
315 +                Text1.Text = Text1.Text & response & vbCrLf
316                  TCPSock.SendData "TCPUpdateTime" & vbCrLf
317 <            Case 5:
317 >            Case 6:
318                  If response = "ERROR" Then GoTo configError
319                  TCPUpdateTime = response
320 +                Text1.Text = Text1.Text & response & vbCrLf
321                  TCPSock.SendData "ENDCONFIG" & vbCrLf
322 <            Case 6:
322 >            Case 7:
323                  If Not response = "OK" Then GoTo configError
324 +                Text1.Text = Text1.Text & response & vbCrLf
325                  TCPSock.SendData "FILTER" & vbCrLf
326 <            Case 7:
326 >            Case 8:
327 >                Text1.Text = Text1.Text & response & vbCrLf
328                  'we got a filter list here.
329                  readTo = 0
330                  ' get hostname
# Line 298 | Line 338 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
338                  ' get TCP Port number
339                  filterTCPPort = response
340                  TCPSock.SendData "END" & vbCrLf
341 <            Case 8:
341 >            Case 9:
342                  If Not response = "OK" Then GoTo configError
343                  connected = True
344                  responseNumber = 0
345                  TCPSock.Close
346 <                Text4.Text = Text4.Text & vbCrLf & "  <closed>"
346 >                Text1.Text = Text1.Text & response & vbCrLf
347 >                'Text4.Text = Text4.Text & vbCrLf & "  <closed>"
348                  Status.Caption = "Configuration successful"
349                  Label3.Caption = UDPUpdateTime
350                  Label4.Caption = TCPUpdateTime
# Line 315 | Line 356 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
356          Select Case responseNumber
357              Case 1:
358                  If Not response = "OK" Then GoTo heartbeatError
359 +                Text1.Text = "Performing heartbeat: -" & vbCrLf
360 +                Text1.Text = Text1.Text & response & vbCrLf
361                  TCPSock.SendData "CONFIG" & vbCrLf
362              Case 2:
363                  If Not response = "OK" Then GoTo heartbeatError
364 +                Text1.Text = Text1.Text & response & vbCrLf
365                  TCPSock.SendData fileList & vbCrLf
366              Case 3:
367                  If Not response = "OK" Then GoTo heartbeatError
368 +                Text1.Text = Text1.Text & response & vbCrLf
369                  TCPSock.SendData lastModified & vbCrLf
370              Case 4:
371                  If Not response = "OK" Then GoTo heartbeatError
372 +                Text1.Text = Text1.Text & response & vbCrLf
373                  TCPSock.SendData "ENDHEARTBEAT" & vbCrLf
374              Case 5:
375                  If Not response = "OK" Then GoTo heartbeatError
376 +                Text1.Text = Text1.Text & response & vbCrLf
377                  TCPSock.Close
378                  Status.Caption = "Heartbeat sent successfully."
379          End Select
# Line 355 | Line 402 | Private Sub Timer1_Timer()
402          
403          ' prepare the contents of the XML packet.
404          seqNo = seqNo + 1
405 <        machineName = TCPSock.LocalHostName
405 >        
406 >        ' Comment this line in the next protocol
407 >        'machineName = TCPSock.LocalHostName
408 >        
409          LocalIP = TCPSock.LocalIP
410          packetDate = Date2Num()
411          
# Line 368 | Line 418 | Private Sub Timer1_Timer()
418              End
419          End If
420            
421 <        osName = getVersion()
421 >        osName = GetVersion()
422          osVersionMajor = verinfo.dwMajorVersion
423          osVersionMinor = verinfo.dwMinorVersion
424          osBuild = verinfo.dwBuildNumber
# Line 394 | Line 444 | Private Sub Timer1_Timer()
444          Dim memory&
445          GlobalMemoryStatus memsts
446          memory& = memsts.dwTotalPhys
447 <        memTotal = memory& \ 1024
447 >        memTotal = memory& \ 1048576
448          memory& = memsts.dwAvailPhys
449 <        memFree = memory& \ 1024
449 >        memFree = memory& \ 1048576
450          memory& = memsts.dwTotalVirtual
451 <        swapTotal = memory& \ 1024
451 >        swapTotal = memory& \ 1048576
452          memory& = memsts.dwAvailVirtual
453 <        swapFree = memory& \ 1024
453 >        swapFree = memory& \ 1048576
454          
455 +        uptime = CUpTime.MilliSecs \ 1000
456 +        
457 +        CUpTime.Capture
458 +        cpu_time = CUpTime.CPUTime
459 +        percent_idle = CUpTime.PercentIdle
460 +        
461 +        userCount = wksta.LoggedOnUsers
462 +        
463          ' build the contents of the XML packet
464          xml = "<packet seq_no=""" & seqNo & """ machine_name=""" & machineName & """ date=""" & packetDate & """ type=""data"" ip=""" & LocalIP & """>" & _
465                "<os>" & _
# Line 411 | Line 469 | Private Sub Timer1_Timer()
469                  "<platform>" & osName & "</platform>" & _
470                  "<minor_version>" & osVersionMinor & "</minor_version>" & _
471                  "<processor>" & processorType & "</processor>" & _
472 +                "<uptime>" & uptime & "</uptime>" & _
473                "</os>" & _
474 +              "<users><count>" & userCount & "</count></users>" & _
475 +              "<cpu><idle>" & percent_idle & "</idle><user>" & cpu_time & "</user></cpu>" & _
476                "<memory><total>" & memTotal & "</total><free>" & memFree & "</free></memory>" & _
477                "<swap><total>" & swapTotal & "</total><free>" & swapFree & "</free></swap>" & _
478                "</packet>"
479 <        Text4.Text = Text4.Text + xml
479 >        Text1.Text = "Last packet contained: -" & vbCrLf & xml
480  
481          ' Use the first winsock control to send a UDP packet.
482          UDPSock.RemoteHost = filterHostname

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines