--- experimental/host/vb_net_test/nettest.frm 2001/02/23 17:08:37 1.15 +++ experimental/host/vb_net_test/nettest.frm 2001/02/26 09:23:34 1.21 @@ -2,14 +2,16 @@ VERSION 5.00 Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX" Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0"; "SysTray.ocx" Begin VB.Form Form1 - BorderStyle = 4 'Fixed ToolWindow + BorderStyle = 3 'Fixed Dialog Caption = "i-scream Winhost" ClientHeight = 5655 ClientLeft = 45 - ClientTop = 285 + ClientTop = 330 ClientWidth = 4710 + Icon = "nettest.frx":0000 LinkTopic = "Form1" MaxButton = 0 'False + MinButton = 0 'False ScaleHeight = 5655 ScaleWidth = 4710 ShowInTaskbar = 0 'False @@ -40,7 +42,7 @@ Begin VB.Form Form1 MultiLine = -1 'True ScrollBars = 2 'Vertical TabIndex = 1 - Text = "nettest.frx":0000 + Text = "nettest.frx":0742 Top = 3000 Width = 3975 End @@ -67,6 +69,23 @@ Begin VB.Form Form1 _Version = 393216 Protocol = 1 End + Begin VB.Label Label5 + Caption = "b e t a" + BeginProperty Font + Name = "MS Sans Serif" + Size = 24 + Charset = 0 + Weight = 700 + Underline = 0 'False + Italic = 0 'False + Strikethrough = 0 'False + EndProperty + Height = 615 + Left = 240 + TabIndex = 8 + Top = 120 + Width = 1815 + End Begin VB.Label Label2 Alignment = 1 'Right Justify Caption = "Next heartbeat:" @@ -107,10 +126,10 @@ Begin VB.Form Form1 Alignment = 2 'Center Caption = "Status:" Height = 255 - Left = 120 + Left = 0 TabIndex = 2 Top = 1320 - Width = 4455 + Width = 4695 End End Attribute VB_Name = "Form1" @@ -123,7 +142,7 @@ Private Declare Function GetPrivateProfileString Lib " Private Declare Function GetPrivateProfileInt Lib "kernel32" Alias "GetPrivateProfileIntA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal nDefault As Long, ByVal lpFileName As String) As Long Dim filterManagerHostname As String -Dim filterManagerTCPPort As Integer +Dim filterManagerTCPPort As Long Dim seqNo As Long Dim machineName As String @@ -139,6 +158,9 @@ Dim TCPUpdateTime As Integer Dim protocolVersion As String Dim connected As Boolean + +Dim CUpTime As New CUpTime + Dim responseNumber As Integer Private Sub Form_Load() @@ -146,34 +168,44 @@ Private Sub Form_Load() protocolVersion = "1.1" Status.Caption = "Loading" - 'Form1.Caption = "i-scream Winhost " & protocolVersion & " for " & GetVersion() + Form1.Caption = "i-scream Winhost " & protocolVersion + Form1.Show + + CUpTime.Init + + If CUpTime.isWin9x Then + x = MsgBox("Sorry, the i-scream host can only be used to monitor servers (i.e. not Win9x)", 48, "Not a server.") + End + End If + ''''TEMP - filterManagerHostname = "killigrew.ukc.ac.uk" - filterManagerTCPPort = 4567 + 'filterManagerHostname = "killigrew.ukc.ac.uk" + 'filterManagerTCPPort = 4567 ''''' END TEMP - GoTo skip + 'GoTo skip On Error GoTo iniError Dim buf As String * 256 Dim length As Long - length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "", buf, Len(buf), App.Path & "winhost.ini") + length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "", buf, Len(buf), App.Path & "/winhost.ini") filterManagerHostname = Left$(buf, length) - length = GetPrivateProfileString("i-scream Winhost", "FilterManagerPort", "", buf, Len(buf), App.Path & "winhost.ini") - filterManagerTCPPort = Left$(buf, length) + length = GetPrivateProfileInt("i-scream Winhost", "FilterManagerPort", 0, App.Path & "/winhost.ini") + filterManagerTCPPort = length + On Error GoTo 0 skip: - Status.Caption = "Connecting to Filter Manager" + Status.Caption = "Connecting to Filter Manager " & filterManagerHostname & ":" & filterManagerTCPPort Reconfigure_Click - Form1.Show + SystemTray.Icon = Val(Form1.Icon) SystemTray.Action = 0 Exit Sub iniError: - x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file. Please correct these and try again.", 48, "Configuration not found") + x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file. Please correct these and try again. " & Err.Description, 48, "Configuration not found") End End Sub @@ -335,7 +367,7 @@ Private Sub Timer1_Timer() ' prepare the contents of the XML packet. seqNo = seqNo + 1 machineName = TCPSock.LocalHostName - localIP = TCPSock.localIP + LocalIP = TCPSock.LocalIP packetDate = Date2Num() @@ -347,7 +379,7 @@ Private Sub Timer1_Timer() End End If - osName = getVersion() + osName = GetVersion() osVersionMajor = verinfo.dwMajorVersion osVersionMinor = verinfo.dwMinorVersion osBuild = verinfo.dwBuildNumber @@ -381,8 +413,10 @@ Private Sub Timer1_Timer() memory& = memsts.dwAvailVirtual swapFree = memory& \ 1024 + uptime = GetTickCount \ 1000 + ' build the contents of the XML packet - xml = "" & _ + xml = "" & _ "" & _ "" & osName & "" & _ "" & osVersionMajor & "" & _ @@ -390,10 +424,11 @@ Private Sub Timer1_Timer() "" & osName & "" & _ "" & osVersionMinor & "" & _ "" & processorType & "" & _ + "" & uptime & "" & _ "" & _ "" & memTotal & "" & memFree & "" & _ "" & swapTotal & "" & swapFree & "" & _ - "" + "" Text4.Text = Text4.Text + xml ' Use the first winsock control to send a UDP packet.