--- experimental/host/vb_net_test/nettest.frm 2001/02/26 09:23:34 1.21 +++ experimental/host/vb_net_test/nettest.frm 2001/02/28 09:08:08 1.26 @@ -4,7 +4,7 @@ Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0 Begin VB.Form Form1 BorderStyle = 3 'Fixed Dialog Caption = "i-scream Winhost" - ClientHeight = 5655 + ClientHeight = 4905 ClientLeft = 45 ClientTop = 330 ClientWidth = 4710 @@ -12,86 +12,78 @@ Begin VB.Form Form1 LinkTopic = "Form1" MaxButton = 0 'False MinButton = 0 'False - ScaleHeight = 5655 + ScaleHeight = 4905 ScaleWidth = 4710 ShowInTaskbar = 0 'False - StartUpPosition = 3 'Windows Default + StartUpPosition = 2 'CenterScreen + Visible = 0 'False + Begin VB.CommandButton Command1 + Caption = "more" + Height = 255 + Left = 3960 + TabIndex = 8 + Top = 840 + Width = 615 + End + Begin VB.TextBox Text1 + Height = 2055 + Left = 120 + Locked = -1 'True + MultiLine = -1 'True + ScrollBars = 2 'Vertical + TabIndex = 7 + Top = 1200 + Width = 4455 + End Begin VB.CommandButton Hide Caption = "Hide Window" Height = 375 Left = 3120 - TabIndex = 7 - Top = 840 + TabIndex = 6 + Top = 240 Width = 1455 End Begin SysTray.SystemTray SystemTray - Left = 2160 - Top = 1800 + Left = 2520 + Top = 4200 _ExtentX = 847 _ExtentY = 847 SysTrayText = "i-scream Winhost" IconFile = 0 End Begin VB.Timer Timer1 - Left = 2760 - Top = 1800 + Left = 3120 + Top = 4200 End - Begin VB.TextBox Text4 - Height = 1575 - Left = 240 - MultiLine = -1 'True - ScrollBars = 2 'Vertical - TabIndex = 1 - Text = "nettest.frx":0742 - Top = 3000 - Width = 3975 - End Begin VB.CommandButton Reconfigure Caption = "Reconfigure with FilterManager" Height = 375 - Left = 120 + Left = 840 TabIndex = 0 - Top = 840 + Top = 3480 Width = 2895 End Begin MSWinsockLib.Winsock TCPSock - Left = 3720 - Top = 1800 + Left = 4080 + Top = 4200 _ExtentX = 741 _ExtentY = 741 _Version = 393216 End Begin MSWinsockLib.Winsock UDPSock - Left = 3240 - Top = 1800 + Left = 3600 + Top = 4200 _ExtentX = 741 _ExtentY = 741 _Version = 393216 Protocol = 1 End - Begin VB.Label Label5 - Caption = "b e t a" - BeginProperty Font - Name = "MS Sans Serif" - Size = 24 - Charset = 0 - Weight = 700 - Underline = 0 'False - Italic = 0 'False - Strikethrough = 0 'False - EndProperty - Height = 615 - Left = 240 - TabIndex = 8 - Top = 120 - Width = 1815 - End Begin VB.Label Label2 Alignment = 1 'Right Justify Caption = "Next heartbeat:" Height = 255 - Left = 2400 - TabIndex = 6 + Left = 120 + TabIndex = 5 Top = 480 Width = 1455 End @@ -99,8 +91,8 @@ Begin VB.Form Form1 Alignment = 1 'Right Justify Caption = "Next UDP packet:" Height = 255 - Left = 2400 - TabIndex = 5 + Left = 120 + TabIndex = 4 Top = 120 Width = 1455 End @@ -108,8 +100,8 @@ Begin VB.Form Form1 BorderStyle = 1 'Fixed Single Caption = "0" Height = 255 - Left = 3960 - TabIndex = 4 + Left = 1680 + TabIndex = 3 Top = 480 Width = 615 End @@ -117,8 +109,8 @@ Begin VB.Form Form1 BorderStyle = 1 'Fixed Single Caption = "0" Height = 255 - Left = 3960 - TabIndex = 3 + Left = 1680 + TabIndex = 2 Top = 120 Width = 615 End @@ -127,9 +119,9 @@ Begin VB.Form Form1 Caption = "Status:" Height = 255 Left = 0 - TabIndex = 2 - Top = 1320 - Width = 4695 + TabIndex = 1 + Top = 840 + Width = 3855 End End Attribute VB_Name = "Form1" @@ -160,25 +152,47 @@ Dim protocolVersion As String Dim connected As Boolean Dim CUpTime As New CUpTime +Dim wksta As New CNetWksta +Dim windowBig As Boolean + Dim responseNumber As Integer +Private Sub Command1_Click() + + ' Toggle visibility of the debug output. + + If windowBig Then + Form1.Height = 1500 + windowBig = False + Else + Form1.Height = 4350 + windowBig = True + End If + +End Sub + Private Sub Form_Load() + If App.PrevInstance Then + x = MsgBox("There is already an i-scream Winhost running on this machine.", 48, "i-scream host already running") + End + End If + protocolVersion = "1.1" Status.Caption = "Loading" Form1.Caption = "i-scream Winhost " & protocolVersion - Form1.Show - CUpTime.Init If CUpTime.isWin9x Then - x = MsgBox("Sorry, the i-scream host can only be used to monitor servers (i.e. not Win9x)", 48, "Not a server.") + x = MsgBox("Sorry, the i-scream host can only be used to monitor servers (i.e. not Win9x)", 48, "Not a server") End End If + windowBig = False + ''''TEMP 'filterManagerHostname = "killigrew.ukc.ac.uk" 'filterManagerTCPPort = 4567 @@ -192,6 +206,9 @@ Private Sub Form_Load() filterManagerHostname = Left$(buf, length) length = GetPrivateProfileInt("i-scream Winhost", "FilterManagerPort", 0, App.Path & "/winhost.ini") filterManagerTCPPort = length + If filterManagerHostname = "" Then + GoTo iniError + End If On Error GoTo 0 skip: @@ -238,7 +255,6 @@ Private Sub SystemTray_MouseDblClk(ByVal Button As Int Form1.Visible = True Form1.SetFocus - End Sub @@ -267,7 +283,7 @@ Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo ' Remove linefeeds and returns from the line. response = Replace(response, Chr(13), "") response = Replace(response, Chr(10), "") - Text4.Text = Text4.Text & vbCrLf & response + 'Text4.Text = Text4.Text & vbCrLf & response If connected = False Then ' Perform TCP configuration (1.1) @@ -276,26 +292,42 @@ Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo Case 1: If Not response = "OK" Then GoTo configError TCPSock.SendData "LASTMODIFIED" & vbCrLf + Text1.Text = "Requesting configuration from FilterManager:- " & vbCrLf + Text1.Text = Text1.Text & response & vbCrLf Case 2: If response = "ERROR" Then GoTo configError lastModified = response + Text1.Text = Text1.Text & response & vbCrLf TCPSock.SendData "FILELIST" & vbCrLf + ''' Uncomment this for new protocol release. + 'Case 2a: + 'If response = "ERROR" Then GoTo configError + 'fileList = response + 'Text1.Text = Text1.Text & response & vbCrLf + 'TCPSock.SendData "FQDN" & vbCrLf Case 3: If response = "ERROR" Then GoTo configError fileList = response + Text1.Text = Text1.Text & response & vbCrLf + ' REMOVE above line, uncomment next + 'machineName = response TCPSock.SendData "UDPUpdateTime" & vbCrLf Case 4: If response = "ERROR" Then GoTo configError UDPUpdateTime = response + Text1.Text = Text1.Text & response & vbCrLf TCPSock.SendData "TCPUpdateTime" & vbCrLf Case 5: If response = "ERROR" Then GoTo configError TCPUpdateTime = response + Text1.Text = Text1.Text & response & vbCrLf TCPSock.SendData "ENDCONFIG" & vbCrLf Case 6: If Not response = "OK" Then GoTo configError + Text1.Text = Text1.Text & response & vbCrLf TCPSock.SendData "FILTER" & vbCrLf Case 7: + Text1.Text = Text1.Text & response & vbCrLf 'we got a filter list here. readTo = 0 ' get hostname @@ -314,7 +346,8 @@ Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo connected = True responseNumber = 0 TCPSock.Close - Text4.Text = Text4.Text & vbCrLf & " " + Text1.Text = Text1.Text & response & vbCrLf + 'Text4.Text = Text4.Text & vbCrLf & " " Status.Caption = "Configuration successful" Label3.Caption = UDPUpdateTime Label4.Caption = TCPUpdateTime @@ -326,18 +359,24 @@ Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo Select Case responseNumber Case 1: If Not response = "OK" Then GoTo heartbeatError + Text1.Text = "Performing heartbeat: -" & vbCrLf + Text1.Text = Text1.Text & response & vbCrLf TCPSock.SendData "CONFIG" & vbCrLf Case 2: If Not response = "OK" Then GoTo heartbeatError + Text1.Text = Text1.Text & response & vbCrLf TCPSock.SendData fileList & vbCrLf Case 3: If Not response = "OK" Then GoTo heartbeatError + Text1.Text = Text1.Text & response & vbCrLf TCPSock.SendData lastModified & vbCrLf Case 4: If Not response = "OK" Then GoTo heartbeatError + Text1.Text = Text1.Text & response & vbCrLf TCPSock.SendData "ENDHEARTBEAT" & vbCrLf Case 5: If Not response = "OK" Then GoTo heartbeatError + Text1.Text = Text1.Text & response & vbCrLf TCPSock.Close Status.Caption = "Heartbeat sent successfully." End Select @@ -366,7 +405,10 @@ Private Sub Timer1_Timer() ' prepare the contents of the XML packet. seqNo = seqNo + 1 + + ' Comment this line in the next protocol machineName = TCPSock.LocalHostName + LocalIP = TCPSock.LocalIP packetDate = Date2Num() @@ -413,8 +455,12 @@ Private Sub Timer1_Timer() memory& = memsts.dwAvailVirtual swapFree = memory& \ 1024 - uptime = GetTickCount \ 1000 + uptime = CUpTime.MilliSecs \ 1000 + CUpTime.Capture + cpu_time = CUpTime.CPUTime + percent_idle = CUpTime.PercentIdle + ' build the contents of the XML packet xml = "" & _ "" & _ @@ -426,10 +472,11 @@ Private Sub Timer1_Timer() "" & processorType & "" & _ "" & uptime & "" & _ "" & _ + "" & percent_idle & "" & cpu_time & "" & _ "" & memTotal & "" & memFree & "" & _ "" & swapTotal & "" & swapFree & "" & _ "" - Text4.Text = Text4.Text + xml + Text1.Text = "Last packet contained: -" & vbCrLf & xml ' Use the first winsock control to send a UDP packet. UDPSock.RemoteHost = filterHostname