ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/experimental/host/vb_net_test/nettest.frm
(Generate patch)

Comparing experimental/host/vb_net_test/nettest.frm (file contents):
Revision 1.22 by pjm2, Mon Feb 26 09:25:41 2001 UTC vs.
Revision 1.26 by pjm2, Wed Feb 28 09:08:08 2001 UTC

# Line 4 | Line 4 | Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0
4   Begin VB.Form Form1
5     BorderStyle     =   3  'Fixed Dialog
6     Caption         =   "i-scream Winhost"
7 <   ClientHeight    =   5655
7 >   ClientHeight    =   4905
8     ClientLeft      =   45
9     ClientTop       =   330
10     ClientWidth     =   4710
# Line 12 | Line 12 | Begin VB.Form Form1
12     LinkTopic       =   "Form1"
13     MaxButton       =   0   'False
14     MinButton       =   0   'False
15 <   ScaleHeight     =   5655
15 >   ScaleHeight     =   4905
16     ScaleWidth      =   4710
17     ShowInTaskbar   =   0   'False
18 <   StartUpPosition =   3  'Windows Default
18 >   StartUpPosition =   2  'CenterScreen
19 >   Visible         =   0   'False
20 >   Begin VB.CommandButton Command1
21 >      Caption         =   "more"
22 >      Height          =   255
23 >      Left            =   3960
24 >      TabIndex        =   8
25 >      Top             =   840
26 >      Width           =   615
27 >   End
28 >   Begin VB.TextBox Text1
29 >      Height          =   2055
30 >      Left            =   120
31 >      Locked          =   -1  'True
32 >      MultiLine       =   -1  'True
33 >      ScrollBars      =   2  'Vertical
34 >      TabIndex        =   7
35 >      Top             =   1200
36 >      Width           =   4455
37 >   End
38     Begin VB.CommandButton Hide
39        Caption         =   "Hide Window"
40        Height          =   375
41        Left            =   3120
42 <      TabIndex        =   7
43 <      Top             =   840
42 >      TabIndex        =   6
43 >      Top             =   240
44        Width           =   1455
45     End
46     Begin SysTray.SystemTray SystemTray
47 <      Left            =   2160
48 <      Top             =   1800
47 >      Left            =   2520
48 >      Top             =   4200
49        _ExtentX        =   847
50        _ExtentY        =   847
51        SysTrayText     =   "i-scream Winhost"
52        IconFile        =   0
53     End
54     Begin VB.Timer Timer1
55 <      Left            =   2760
56 <      Top             =   1800
55 >      Left            =   3120
56 >      Top             =   4200
57     End
39   Begin VB.TextBox Text4
40      Height          =   1575
41      Left            =   240
42      MultiLine       =   -1  'True
43      ScrollBars      =   2  'Vertical
44      TabIndex        =   1
45      Text            =   "nettest.frx":0742
46      Top             =   3000
47      Width           =   3975
48   End
58     Begin VB.CommandButton Reconfigure
59        Caption         =   "Reconfigure with FilterManager"
60        Height          =   375
61 <      Left            =   120
61 >      Left            =   840
62        TabIndex        =   0
63 <      Top             =   840
63 >      Top             =   3480
64        Width           =   2895
65     End
66     Begin MSWinsockLib.Winsock TCPSock
67 <      Left            =   3720
68 <      Top             =   1800
67 >      Left            =   4080
68 >      Top             =   4200
69        _ExtentX        =   741
70        _ExtentY        =   741
71        _Version        =   393216
72     End
73     Begin MSWinsockLib.Winsock UDPSock
74 <      Left            =   3240
75 <      Top             =   1800
74 >      Left            =   3600
75 >      Top             =   4200
76        _ExtentX        =   741
77        _ExtentY        =   741
78        _Version        =   393216
79        Protocol        =   1
80     End
72   Begin VB.Label Label5
73      Caption         =   "b e t a"
74      BeginProperty Font
75         Name            =   "MS Sans Serif"
76         Size            =   24
77         Charset         =   0
78         Weight          =   700
79         Underline       =   0   'False
80         Italic          =   0   'False
81         Strikethrough   =   0   'False
82      EndProperty
83      Height          =   615
84      Left            =   240
85      TabIndex        =   8
86      Top             =   120
87      Width           =   1815
88   End
81     Begin VB.Label Label2
82        Alignment       =   1  'Right Justify
83        Caption         =   "Next heartbeat:"
84        Height          =   255
85 <      Left            =   2400
86 <      TabIndex        =   6
85 >      Left            =   120
86 >      TabIndex        =   5
87        Top             =   480
88        Width           =   1455
89     End
# Line 99 | Line 91 | Begin VB.Form Form1
91        Alignment       =   1  'Right Justify
92        Caption         =   "Next UDP packet:"
93        Height          =   255
94 <      Left            =   2400
95 <      TabIndex        =   5
94 >      Left            =   120
95 >      TabIndex        =   4
96        Top             =   120
97        Width           =   1455
98     End
# Line 108 | Line 100 | Begin VB.Form Form1
100        BorderStyle     =   1  'Fixed Single
101        Caption         =   "0"
102        Height          =   255
103 <      Left            =   3960
104 <      TabIndex        =   4
103 >      Left            =   1680
104 >      TabIndex        =   3
105        Top             =   480
106        Width           =   615
107     End
# Line 117 | Line 109 | Begin VB.Form Form1
109        BorderStyle     =   1  'Fixed Single
110        Caption         =   "0"
111        Height          =   255
112 <      Left            =   3960
113 <      TabIndex        =   3
112 >      Left            =   1680
113 >      TabIndex        =   2
114        Top             =   120
115        Width           =   615
116     End
# Line 127 | Line 119 | Begin VB.Form Form1
119        Caption         =   "Status:"
120        Height          =   255
121        Left            =   0
122 <      TabIndex        =   2
123 <      Top             =   1320
124 <      Width           =   4695
122 >      TabIndex        =   1
123 >      Top             =   840
124 >      Width           =   3855
125     End
126   End
127   Attribute VB_Name = "Form1"
# Line 160 | Line 152 | Dim protocolVersion As String
152   Dim connected As Boolean
153  
154   Dim CUpTime As New CUpTime
155 + Dim wksta As New CNetWksta
156  
157 + Dim windowBig As Boolean
158 +
159   Dim responseNumber As Integer
160  
161 + Private Sub Command1_Click()
162 +
163 +    ' Toggle visibility of the debug output.
164 +
165 +    If windowBig Then
166 +        Form1.Height = 1500
167 +        windowBig = False
168 +    Else
169 +        Form1.Height = 4350
170 +        windowBig = True
171 +    End If
172 +
173 + End Sub
174 +
175   Private Sub Form_Load()
176      
177      If App.PrevInstance Then
178          x = MsgBox("There is already an i-scream Winhost running on this machine.", 48, "i-scream host already running")
179 +        End
180      End If
181      
182      protocolVersion = "1.1"
# Line 174 | Line 184 | Private Sub Form_Load()
184      Status.Caption = "Loading"
185      Form1.Caption = "i-scream Winhost " & protocolVersion
186      
177    Form1.Show
178    
187      CUpTime.Init
188      
189      If CUpTime.isWin9x Then
190 <        x = MsgBox("Sorry, the i-scream host can only be used to monitor servers (i.e. not Win9x)", 48, "Not a server.")
190 >        x = MsgBox("Sorry, the i-scream host can only be used to monitor servers (i.e. not Win9x)", 48, "Not a server")
191          End
192      End If
193      
194 +    windowBig = False
195 +    
196      ''''TEMP
197      'filterManagerHostname = "killigrew.ukc.ac.uk"
198      'filterManagerTCPPort = 4567
# Line 196 | Line 206 | Private Sub Form_Load()
206      filterManagerHostname = Left$(buf, length)
207      length = GetPrivateProfileInt("i-scream Winhost", "FilterManagerPort", 0, App.Path & "/winhost.ini")
208      filterManagerTCPPort = length
209 +    If filterManagerHostname = "" Then
210 +        GoTo iniError
211 +    End If
212      On Error GoTo 0
213   skip:
214  
# Line 242 | Line 255 | Private Sub SystemTray_MouseDblClk(ByVal Button As Int
255  
256      Form1.Visible = True
257      Form1.SetFocus
245    
258  
259   End Sub
260  
# Line 271 | Line 283 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
283      ' Remove linefeeds and returns from the line.
284      response = Replace(response, Chr(13), "")
285      response = Replace(response, Chr(10), "")
286 <    Text4.Text = Text4.Text & vbCrLf & response
286 >    'Text4.Text = Text4.Text & vbCrLf & response
287      
288      If connected = False Then
289          ' Perform TCP configuration (1.1)
# Line 280 | Line 292 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
292              Case 1:
293                  If Not response = "OK" Then GoTo configError
294                  TCPSock.SendData "LASTMODIFIED" & vbCrLf
295 +                Text1.Text = "Requesting configuration from FilterManager:- " & vbCrLf
296 +                Text1.Text = Text1.Text & response & vbCrLf
297              Case 2:
298                  If response = "ERROR" Then GoTo configError
299                  lastModified = response
300 +                Text1.Text = Text1.Text & response & vbCrLf
301                  TCPSock.SendData "FILELIST" & vbCrLf
302 +            ''' Uncomment this for new protocol release.
303 +            'Case 2a:
304 +                'If response = "ERROR" Then GoTo configError
305 +                'fileList = response
306 +                'Text1.Text = Text1.Text & response & vbCrLf
307 +                'TCPSock.SendData "FQDN" & vbCrLf
308              Case 3:
309                  If response = "ERROR" Then GoTo configError
310                  fileList = response
311 +                Text1.Text = Text1.Text & response & vbCrLf
312 +                ' REMOVE above line, uncomment next
313 +                'machineName = response
314                  TCPSock.SendData "UDPUpdateTime" & vbCrLf
315              Case 4:
316                  If response = "ERROR" Then GoTo configError
317                  UDPUpdateTime = response
318 +                Text1.Text = Text1.Text & response & vbCrLf
319                  TCPSock.SendData "TCPUpdateTime" & vbCrLf
320              Case 5:
321                  If response = "ERROR" Then GoTo configError
322                  TCPUpdateTime = response
323 +                Text1.Text = Text1.Text & response & vbCrLf
324                  TCPSock.SendData "ENDCONFIG" & vbCrLf
325              Case 6:
326                  If Not response = "OK" Then GoTo configError
327 +                Text1.Text = Text1.Text & response & vbCrLf
328                  TCPSock.SendData "FILTER" & vbCrLf
329              Case 7:
330 +                Text1.Text = Text1.Text & response & vbCrLf
331                  'we got a filter list here.
332                  readTo = 0
333                  ' get hostname
# Line 318 | Line 346 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
346                  connected = True
347                  responseNumber = 0
348                  TCPSock.Close
349 <                Text4.Text = Text4.Text & vbCrLf & "  <closed>"
349 >                Text1.Text = Text1.Text & response & vbCrLf
350 >                'Text4.Text = Text4.Text & vbCrLf & "  <closed>"
351                  Status.Caption = "Configuration successful"
352                  Label3.Caption = UDPUpdateTime
353                  Label4.Caption = TCPUpdateTime
# Line 330 | Line 359 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
359          Select Case responseNumber
360              Case 1:
361                  If Not response = "OK" Then GoTo heartbeatError
362 +                Text1.Text = "Performing heartbeat: -" & vbCrLf
363 +                Text1.Text = Text1.Text & response & vbCrLf
364                  TCPSock.SendData "CONFIG" & vbCrLf
365              Case 2:
366                  If Not response = "OK" Then GoTo heartbeatError
367 +                Text1.Text = Text1.Text & response & vbCrLf
368                  TCPSock.SendData fileList & vbCrLf
369              Case 3:
370                  If Not response = "OK" Then GoTo heartbeatError
371 +                Text1.Text = Text1.Text & response & vbCrLf
372                  TCPSock.SendData lastModified & vbCrLf
373              Case 4:
374                  If Not response = "OK" Then GoTo heartbeatError
375 +                Text1.Text = Text1.Text & response & vbCrLf
376                  TCPSock.SendData "ENDHEARTBEAT" & vbCrLf
377              Case 5:
378                  If Not response = "OK" Then GoTo heartbeatError
379 +                Text1.Text = Text1.Text & response & vbCrLf
380                  TCPSock.Close
381                  Status.Caption = "Heartbeat sent successfully."
382          End Select
# Line 370 | Line 405 | Private Sub Timer1_Timer()
405          
406          ' prepare the contents of the XML packet.
407          seqNo = seqNo + 1
408 +        
409 +        ' Comment this line in the next protocol
410          machineName = TCPSock.LocalHostName
411 +        
412          LocalIP = TCPSock.LocalIP
413          packetDate = Date2Num()
414          
# Line 417 | Line 455 | Private Sub Timer1_Timer()
455          memory& = memsts.dwAvailVirtual
456          swapFree = memory& \ 1024
457          
458 <        uptime = GetTickCount \ 1000
458 >        uptime = CUpTime.MilliSecs \ 1000
459          
460 +        CUpTime.Capture
461 +        cpu_time = CUpTime.CPUTime
462 +        percent_idle = CUpTime.PercentIdle
463 +        
464          ' build the contents of the XML packet
465          xml = "<packet seq_no=""" & seqNo & """ machine_name=""" & machineName & """ date=""" & packetDate & """ type=""data"" ip=""" & LocalIP & """>" & _
466                "<os>" & _
# Line 430 | Line 472 | Private Sub Timer1_Timer()
472                  "<processor>" & processorType & "</processor>" & _
473                  "<uptime>" & uptime & "</uptime>" & _
474                "</os>" & _
475 +              "<cpu><idle>" & percent_idle & "</idle><user>" & cpu_time & "</user></cpu>" & _
476                "<memory><total>" & memTotal & "</total><free>" & memFree & "</free></memory>" & _
477                "<swap><total>" & swapTotal & "</total><free>" & swapFree & "</free></swap>" & _
478                "</packet>"
479 <        Text4.Text = Text4.Text + xml
479 >        Text1.Text = "Last packet contained: -" & vbCrLf & xml
480  
481          ' Use the first winsock control to send a UDP packet.
482          UDPSock.RemoteHost = filterHostname

Diff Legend

Removed lines
+ Added lines
< Changed lines