ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/experimental/host/vb_net_test/nettest.frm
(Generate patch)

Comparing experimental/host/vb_net_test/nettest.frm (file contents):
Revision 1.10 by pjm2, Fri Feb 23 11:42:06 2001 UTC vs.
Revision 1.31 by pjm2, Wed Feb 28 12:04:17 2001 UTC

# Line 1 | Line 1
1   VERSION 5.00
2   Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX"
3 + Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0"; "SysTray.ocx"
4   Begin VB.Form Form1
5 <   BorderStyle     =   4  'Fixed ToolWindow
5 >   BorderStyle     =   3  'Fixed Dialog
6     Caption         =   "i-scream Winhost"
7 <   ClientHeight    =   5655
7 >   ClientHeight    =   1185
8     ClientLeft      =   45
9 <   ClientTop       =   285
10 <   ClientWidth     =   5670
9 >   ClientTop       =   330
10 >   ClientWidth     =   4710
11 >   Icon            =   "nettest.frx":0000
12     LinkTopic       =   "Form1"
13     MaxButton       =   0   'False
14     MinButton       =   0   'False
15 <   ScaleHeight     =   5655
16 <   ScaleWidth      =   5670
15 >   ScaleHeight     =   1185
16 >   ScaleWidth      =   4710
17     ShowInTaskbar   =   0   'False
18 <   StartUpPosition =   3  'Windows Default
19 <   Begin VB.Timer Timer1
20 <      Left            =   4200
21 <      Top             =   1200
18 >   StartUpPosition =   2  'CenterScreen
19 >   Visible         =   0   'False
20 >   Begin VB.CommandButton Command1
21 >      Caption         =   "more"
22 >      Height          =   255
23 >      Left            =   3960
24 >      TabIndex        =   8
25 >      Top             =   840
26 >      Width           =   615
27     End
28 <   Begin VB.TextBox Text4
29 <      Height          =   1575
30 <      Left            =   240
28 >   Begin VB.TextBox Text1
29 >      Height          =   2055
30 >      Left            =   120
31 >      Locked          =   -1  'True
32        MultiLine       =   -1  'True
33        ScrollBars      =   2  'Vertical
34 <      TabIndex        =   1
35 <      Text            =   "nettest.frx":0000
36 <      Top             =   3000
29 <      Width           =   5055
34 >      TabIndex        =   7
35 >      Top             =   1200
36 >      Width           =   4455
37     End
38 +   Begin VB.CommandButton Hide
39 +      Caption         =   "hide"
40 +      Height          =   255
41 +      Left            =   3960
42 +      TabIndex        =   6
43 +      Top             =   480
44 +      Width           =   615
45 +   End
46 +   Begin SysTray.SystemTray SystemTray
47 +      Left            =   2520
48 +      Top             =   4200
49 +      _ExtentX        =   847
50 +      _ExtentY        =   847
51 +      SysTrayText     =   "i-scream Winhost"
52 +      IconFile        =   0
53 +   End
54 +   Begin VB.Timer Timer1
55 +      Left            =   3120
56 +      Top             =   4200
57 +   End
58     Begin VB.CommandButton Reconfigure
59        Caption         =   "Reconfigure with FilterManager"
60 <      Height          =   495
61 <      Left            =   120
60 >      Height          =   375
61 >      Left            =   840
62        TabIndex        =   0
63 <      Top             =   120
63 >      Top             =   3480
64        Width           =   2895
65     End
66     Begin MSWinsockLib.Winsock TCPSock
67 <      Left            =   5160
68 <      Top             =   1200
67 >      Left            =   4080
68 >      Top             =   4200
69        _ExtentX        =   741
70        _ExtentY        =   741
71        _Version        =   393216
72     End
73     Begin MSWinsockLib.Winsock UDPSock
74 <      Left            =   4680
75 <      Top             =   1200
74 >      Left            =   3600
75 >      Top             =   4200
76        _ExtentX        =   741
77        _ExtentY        =   741
78        _Version        =   393216
# Line 55 | Line 82 | Begin VB.Form Form1
82        Alignment       =   1  'Right Justify
83        Caption         =   "Next heartbeat:"
84        Height          =   255
85 <      Left            =   3360
86 <      TabIndex        =   6
85 >      Left            =   120
86 >      TabIndex        =   5
87        Top             =   480
88        Width           =   1455
89     End
# Line 64 | Line 91 | Begin VB.Form Form1
91        Alignment       =   1  'Right Justify
92        Caption         =   "Next UDP packet:"
93        Height          =   255
94 <      Left            =   3360
95 <      TabIndex        =   5
94 >      Left            =   120
95 >      TabIndex        =   4
96        Top             =   120
97        Width           =   1455
98     End
# Line 73 | Line 100 | Begin VB.Form Form1
100        BorderStyle     =   1  'Fixed Single
101        Caption         =   "0"
102        Height          =   255
103 <      Left            =   4920
104 <      TabIndex        =   4
103 >      Left            =   1680
104 >      TabIndex        =   3
105        Top             =   480
106        Width           =   615
107     End
# Line 82 | Line 109 | Begin VB.Form Form1
109        BorderStyle     =   1  'Fixed Single
110        Caption         =   "0"
111        Height          =   255
112 <      Left            =   4920
113 <      TabIndex        =   3
112 >      Left            =   1680
113 >      TabIndex        =   2
114        Top             =   120
115        Width           =   615
116     End
117     Begin VB.Label Status
118 +      Alignment       =   2  'Center
119        Caption         =   "Status:"
120        Height          =   255
121 <      Left            =   120
122 <      TabIndex        =   2
121 >      Left            =   0
122 >      TabIndex        =   1
123        Top             =   840
124 <      Width           =   5415
124 >      Width           =   3855
125     End
126   End
127   Attribute VB_Name = "Form1"
# Line 101 | Line 129 | Attribute VB_GlobalNameSpace = False
129   Attribute VB_Creatable = False
130   Attribute VB_PredeclaredId = True
131   Attribute VB_Exposed = False
132 + ' For the system tray bits
133   Private Declare Function GetPrivateProfileString Lib "kernel32" Alias "GetPrivateProfileStringA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal lpDefault As String, ByVal lpReturnedString As String, ByVal nSize As Long, ByVal lpFileName As String) As Long
134   Private Declare Function GetPrivateProfileInt Lib "kernel32" Alias "GetPrivateProfileIntA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal nDefault As Long, ByVal lpFileName As String) As Long
135  
136   Dim filterManagerHostname As String
137 < Dim filterManagerTCPPort As Integer
137 > Dim filterManagerTCPPort As Long
138  
139 + Dim seqNo As Long
140 + Dim machineName As String
141 +
142   Dim filterHostname As String
143   Dim filterTCPPort As Integer
144   Dim filterUDPPort As Integer
# Line 118 | Line 150 | Dim TCPUpdateTime As Integer
150  
151   Dim protocolVersion As String
152   Dim connected As Boolean
121 Dim responseNumber As Integer
153  
154 + Dim CUpTime As New CUpTime
155 + Dim wksta As New CNetWksta
156  
157 < Private Sub Command1_Click()
157 > Dim windowBig As Boolean
158  
159 <    ' build the contents of the XML packet.
127 <    xml = "<packet></packet>"
159 > Dim responseNumber As Integer
160  
161 <    ' Use the first winsock control to send a UDP packet.
130 <    UDPSock.RemoteHost = filterHostname
131 <    UDPSock.RemotePort = filterUDPPort
132 <    UDPSock.SendData xml
133 <    Status.Caption = "i-scream Winhost " & protocolVersion & " - UDP packet sent."
161 > Private Sub Command1_Click()
162  
163 < End Sub
163 >    ' Toggle visibility of the debug output.
164  
165 +    If windowBig Then
166 +        Form1.Height = 1500
167 +        windowBig = False
168 +    Else
169 +        Form1.Height = 4350
170 +        windowBig = True
171 +    End If
172  
138 Private Sub Command3_Click()
139    ' establish a TCP connection to a filter
140    TCPSock.Close
141    TCPSock.Connect filterHostname, filterTCPPort
173   End Sub
174  
175   Private Sub Form_Load()
176 +    
177 +    If App.PrevInstance Then
178 +        x = MsgBox("There is already an i-scream Winhost running on this machine.", 48, "i-scream host already running")
179 +        End
180 +    End If
181 +    
182      protocolVersion = "1.1"
183 <      
183 >    
184      Status.Caption = "Loading"
185      Form1.Caption = "i-scream Winhost " & protocolVersion
186      
187 +    CUpTime.Init
188 +    
189 +    If CUpTime.isWin9x Then
190 +        x = MsgBox("Sorry, the i-scream host can only be used to monitor servers (i.e. not Win9x)", 48, "Not a server")
191 +        End
192 +    End If
193 +    
194 +    windowBig = False
195 +    
196      ''''TEMP
197 <    filterManagerHostname = "killigrew.ukc.ac.uk"
198 <    filterManagerTCPPort = 4567
199 <    Reconfigure_Click
154 <    Exit Sub
155 <    ''' ENDTEMP
197 >    'filterManagerHostname = "killigrew.ukc.ac.uk"
198 >    'filterManagerTCPPort = 4567
199 >    ''''' END TEMP
200      
201 +    'GoTo skip
202      On Error GoTo iniError
203      Dim buf As String * 256
204      Dim length As Long
205 <    length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "<no value>", buf, Len(buf), App.Path & "winhost.ini")
205 >    length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "<no value>", buf, Len(buf), App.Path & "/winhost.ini")
206      filterManagerHostname = Left$(buf, length)
207 <    length = GetPrivateProfileString("i-scream Winhost", "FilterManagerPort", "<no value>", buf, Len(buf), App.Path & "winhost.ini")
208 <    filterManagerTCPPort = Left$(buf, length)
207 >    length = GetPrivateProfileInt("i-scream Winhost", "FilterManagerPort", 0, App.Path & "/winhost.ini")
208 >    filterManagerTCPPort = length
209 >    If filterManagerHostname = "" Then
210 >        GoTo iniError
211 >    End If
212 >    On Error GoTo 0
213 > skip:
214 >
215 >    Status.Caption = "Connecting to Filter Manager " & filterManagerHostname & ":" & filterManagerTCPPort
216 >    Reconfigure_Click
217      
218 <    Status.Caption = "Connecting to Filter Manager"
218 >    SystemTray.Icon = Val(Form1.Icon)
219 >    SystemTray.Action = 0
220      
221 +    
222      Exit Sub
223      
224   iniError:
225 <    x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file.  Please correct these and try again.", 48, "Configuration not found")
225 >    x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file.  Please correct these and try again.  " & Err.Description, 48, "Configuration not found")
226      End
227      
228   End Sub
229  
230   Private Sub Form_QueryUnload(Cancel As Integer, UnloadMode As Integer)
231 <    x = MsgBox("Are you sure you want to shut down the Winhost?", vbYesNo, "i-scream Winhost")
231 >    x = MsgBox("Are you sure you want to shut down the Winhost?  This will stop your computer sending information to the i-scream Central Monitoring System.", vbYesNo, "i-scream Winhost")
232      If x = 7 Then
233          Cancel = True
234 +    Else
235 +        SystemTray.Action = 2
236      End If
237  
238   End Sub
239  
240 + Private Sub Hide_Click()
241 +    Form1.Visible = False
242 +    SystemTray.Icon = Val(Form1.Icon)
243 + End Sub
244 +
245 + Private Sub Image1_Click()
246 +
247 + End Sub
248 +
249   Private Sub Reconfigure_Click()
250      ' establish a TCP connection to a filtermanager
251      connected = False
# Line 187 | Line 253 | Private Sub Reconfigure_Click()
253      TCPSock.Connect filterManagerHostname, filterManagerTCPPort
254   End Sub
255  
256 +
257 +
258 + Private Sub SystemTray_MouseDblClk(ByVal Button As Integer)
259 +
260 +    Form1.Visible = True
261 +    Form1.SetFocus
262 +
263 + End Sub
264 +
265   Private Sub TCPSock_Connect()
266      
267      responseNumber = 0
# Line 212 | Line 287 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
287      ' Remove linefeeds and returns from the line.
288      response = Replace(response, Chr(13), "")
289      response = Replace(response, Chr(10), "")
215    Text4.Text = Text4.Text & vbCrLf & response
290      
291      If connected = False Then
292          ' Perform TCP configuration (1.1)
# Line 221 | Line 295 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
295              Case 1:
296                  If Not response = "OK" Then GoTo configError
297                  TCPSock.SendData "LASTMODIFIED" & vbCrLf
298 +                Text1.Text = "Requesting configuration from FilterManager:- " & vbCrLf
299 +                Text1.Text = Text1.Text & response & vbCrLf
300              Case 2:
301                  If response = "ERROR" Then GoTo configError
302                  lastModified = response
303 +                Text1.Text = Text1.Text & response & vbCrLf
304                  TCPSock.SendData "FILELIST" & vbCrLf
305 +            ' New addition to the protocol.
306              Case 3:
307                  If response = "ERROR" Then GoTo configError
308                  fileList = response
309 <                TCPSock.SendData "UDPUpdateTime" & vbCrLf
309 >                Text1.Text = Text1.Text & response & vbCrLf
310 >                TCPSock.SendData "FQDN" & vbCrLf
311              Case 4:
312                  If response = "ERROR" Then GoTo configError
313 +                Text1.Text = Text1.Text & response & vbCrLf
314 +                machineName = response
315 +                TCPSock.SendData "UDPUpdateTime" & vbCrLf
316 +            Case 5:
317 +                If response = "ERROR" Then GoTo configError
318                  UDPUpdateTime = response
319 +                Text1.Text = Text1.Text & response & vbCrLf
320                  TCPSock.SendData "TCPUpdateTime" & vbCrLf
321 <            Case 5:
321 >            Case 6:
322                  If response = "ERROR" Then GoTo configError
323                  TCPUpdateTime = response
324 +                Text1.Text = Text1.Text & response & vbCrLf
325                  TCPSock.SendData "ENDCONFIG" & vbCrLf
326 <            Case 6:
326 >            Case 7:
327                  If Not response = "OK" Then GoTo configError
328 +                Text1.Text = Text1.Text & response & vbCrLf
329                  TCPSock.SendData "FILTER" & vbCrLf
330 <            Case 7:
330 >            Case 8:
331 >                Text1.Text = Text1.Text & response & vbCrLf
332                  'we got a filter list here.
333                  readTo = 0
334                  ' get hostname
# Line 254 | Line 342 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
342                  ' get TCP Port number
343                  filterTCPPort = response
344                  TCPSock.SendData "END" & vbCrLf
345 <            Case 8:
345 >            Case 9:
346                  If Not response = "OK" Then GoTo configError
347                  connected = True
348                  responseNumber = 0
349                  TCPSock.Close
350 <                Text4.Text = Text4.Text & vbCrLf & "  <closed>"
350 >                Text1.Text = Text1.Text & response & vbCrLf
351 >                'Text4.Text = Text4.Text & vbCrLf & "  <closed>"
352                  Status.Caption = "Configuration successful"
353                  Label3.Caption = UDPUpdateTime
354                  Label4.Caption = TCPUpdateTime
# Line 271 | Line 360 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
360          Select Case responseNumber
361              Case 1:
362                  If Not response = "OK" Then GoTo heartbeatError
363 +                Text1.Text = "Performing heartbeat: -" & vbCrLf
364 +                Text1.Text = Text1.Text & response & vbCrLf
365                  TCPSock.SendData "CONFIG" & vbCrLf
366              Case 2:
367                  If Not response = "OK" Then GoTo heartbeatError
368 +                Text1.Text = Text1.Text & response & vbCrLf
369                  TCPSock.SendData fileList & vbCrLf
370              Case 3:
371                  If Not response = "OK" Then GoTo heartbeatError
372 +                Text1.Text = Text1.Text & response & vbCrLf
373                  TCPSock.SendData lastModified & vbCrLf
374              Case 4:
375                  If Not response = "OK" Then GoTo heartbeatError
376 +                Text1.Text = Text1.Text & response & vbCrLf
377                  TCPSock.SendData "ENDHEARTBEAT" & vbCrLf
378              Case 5:
379                  If Not response = "OK" Then GoTo heartbeatError
380 +                Text1.Text = Text1.Text & response & vbCrLf
381                  TCPSock.Close
382                  Status.Caption = "Heartbeat sent successfully."
383          End Select
# Line 308 | Line 403 | Private Sub Timer1_Timer()
403      Status.Caption = ""
404      
405      If Label3.Caption < 1 Then
406 <        ' build the contents of the XML packet.
407 <        xml = "<packet></packet>"
406 >        
407 >        ' prepare the contents of the XML packet.
408 >        seqNo = seqNo + 1
409 >        
410 >        netbiosName = TCPSock.LocalHostName
411 >        
412 >        LocalIP = TCPSock.LocalIP
413 >        packetDate = Date2Num()
414 >        
415 >        
416 >        Dim verinfo As OSVERSIONINFO
417 >        verinfo.dwOSVersionInfoSize = Len(verinfo)
418 >        ret% = GetVersionEx(verinfo)
419 >        If ret% = 0 Then
420 >            MsgBox "Error getting Windows version Information"
421 >            End
422 >        End If
423 >          
424 >        osName = GetVersion()
425 >        osVersionMajor = verinfo.dwMajorVersion
426 >        osVersionMinor = verinfo.dwMinorVersion
427 >        osBuild = verinfo.dwBuildNumber
428 >        
429 >        Dim sysinfo As SYSTEM_INFO
430 >        GetSystemInfo sysinfo
431 >        Select Case sysinfo.dwProcessorType
432 >            Case PROCESSOR_INTEL_386
433 >                processorType = "Intel 386"
434 >            Case PROCESSOR_INTEL_486
435 >                processorType = "Intel 486"
436 >            Case PROCESSOR_INTEL_PENTIUM
437 >                processorType = "Intel Pentium variant"
438 >            Case PROCESSOR_MIPS_R4000
439 >                processorType = "MIPS R4000"
440 >            Case PROCESSOR_ALPHA_21064
441 >                processorType = "DEC Alpha 21064"
442 >            Case Else
443 >                processorType = "(unknown)"
444 >        End Select
445 >        
446 >        Dim memsts As MEMORYSTATUS
447 >        Dim memory&
448 >        GlobalMemoryStatus memsts
449 >        memory& = memsts.dwTotalPhys
450 >        memTotal = memory& \ 1048576
451 >        memory& = memsts.dwAvailPhys
452 >        memFree = memory& \ 1048576
453 >        memory& = memsts.dwTotalVirtual
454 >        swapTotal = memory& \ 1048576
455 >        memory& = memsts.dwAvailVirtual
456 >        swapFree = memory& \ 1048576
457 >        
458 >        uptime = CUpTime.MilliSecs \ 1000
459 >        
460 >        CUpTime.Capture
461 >        cpu_time = CUpTime.CPUTime
462 >        percent_idle = CUpTime.PercentIdle
463 >        
464 >        userCount = wksta.LoggedOnUsers
465 >        
466 >        ' build the contents of the XML packet
467 >        xml = "<packet seq_no=""" & seqNo & """ machine_name=""" & machineName & """ date=""" & packetDate & """ type=""data"" ip=""" & LocalIP & """>" & _
468 >              "<os>" & _
469 >                "<netbios_name>" & netbiosName & "</netbios_name>" & _
470 >                "<name>" & osName & "</name>" & _
471 >                "<version>" & osVersionMajor & "</version>" & _
472 >                "<release>" & osBuild & "</release>" & _
473 >                "<platform>" & osName & "</platform>" & _
474 >                "<minor_version>" & osVersionMinor & "</minor_version>" & _
475 >                "<processor>" & processorType & "</processor>" & _
476 >                "<uptime>" & uptime & "</uptime>" & _
477 >              "</os>" & _
478 >              "<users><count>" & userCount & "</count></users>" & _
479 >              "<cpu><idle>" & percent_idle & "</idle><user>" & cpu_time & "</user></cpu>" & _
480 >              "<memory><total>" & memTotal & "</total><free>" & memFree & "</free></memory>" & _
481 >              "<swap><total>" & swapTotal & "</total><free>" & swapFree & "</free></swap>" & _
482 >              "</packet>"
483 >        Text1.Text = "Last packet contained: -" & vbCrLf & xml
484  
485          ' Use the first winsock control to send a UDP packet.
486          UDPSock.RemoteHost = filterHostname
# Line 327 | Line 498 | Private Sub Timer1_Timer()
498      End If
499  
500   End Sub
501 +
502 + Function Date2Num() As Long
503 +    Dim x As Long
504 +    x = DateDiff("s", "1-1-1970", Now)
505 +    Date2Num = x
506 + End Function

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines