ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/projects/cms/source/host/winhost/nettest.frm
(Generate patch)

Comparing projects/cms/source/host/winhost/nettest.frm (file contents):
Revision 1.18 by pjm2, Fri Feb 23 17:51:07 2001 UTC vs.
Revision 1.37 by pjm2, Mon Mar 19 10:32:43 2001 UTC

# Line 4 | Line 4 | Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0
4   Begin VB.Form Form1
5     BorderStyle     =   3  'Fixed Dialog
6     Caption         =   "i-scream Winhost"
7 <   ClientHeight    =   5655
7 >   ClientHeight    =   1380
8     ClientLeft      =   45
9     ClientTop       =   330
10 <   ClientWidth     =   4710
10 >   ClientWidth     =   4635
11 >   Icon            =   "nettest.frx":0000
12     LinkTopic       =   "Form1"
13     MaxButton       =   0   'False
14     MinButton       =   0   'False
15 <   ScaleHeight     =   5655
16 <   ScaleWidth      =   4710
15 >   ScaleHeight     =   1380
16 >   ScaleWidth      =   4635
17     ShowInTaskbar   =   0   'False
18 <   StartUpPosition =   3  'Windows Default
19 <   Begin VB.CommandButton Hide
20 <      Caption         =   "Hide Window"
21 <      Height          =   375
22 <      Left            =   3120
18 >   StartUpPosition =   2  'CenterScreen
19 >   Visible         =   0   'False
20 >   Begin VB.CommandButton Command1
21 >      Caption         =   "more"
22 >      Height          =   255
23 >      Left            =   3885
24 >      TabIndex        =   8
25 >      Top             =   1035
26 >      Width           =   615
27 >   End
28 >   Begin VB.TextBox Text1
29 >      Height          =   2055
30 >      Left            =   120
31 >      Locked          =   -1  'True
32 >      MultiLine       =   -1  'True
33 >      ScrollBars      =   2  'Vertical
34        TabIndex        =   7
35 <      Top             =   840
36 <      Width           =   1455
35 >      Top             =   1440
36 >      Width           =   4395
37     End
38 +   Begin VB.CommandButton Hide
39 +      Caption         =   "hide"
40 +      Height          =   255
41 +      Left            =   3225
42 +      TabIndex        =   6
43 +      Top             =   1035
44 +      Width           =   615
45 +   End
46     Begin SysTray.SystemTray SystemTray
47 <      Left            =   2160
48 <      Top             =   1800
47 >      Left            =   2520
48 >      Top             =   4200
49        _ExtentX        =   847
50        _ExtentY        =   847
51        SysTrayText     =   "i-scream Winhost"
52        IconFile        =   0
53     End
54     Begin VB.Timer Timer1
55 <      Left            =   2760
56 <      Top             =   1800
55 >      Left            =   3120
56 >      Top             =   4200
57     End
38   Begin VB.TextBox Text4
39      Height          =   1575
40      Left            =   240
41      MultiLine       =   -1  'True
42      ScrollBars      =   2  'Vertical
43      TabIndex        =   1
44      Text            =   "nettest.frx":0000
45      Top             =   3000
46      Width           =   3975
47   End
58     Begin VB.CommandButton Reconfigure
59        Caption         =   "Reconfigure with FilterManager"
60        Height          =   375
61 <      Left            =   120
61 >      Left            =   840
62        TabIndex        =   0
63 <      Top             =   840
63 >      Top             =   3555
64        Width           =   2895
65     End
66     Begin MSWinsockLib.Winsock TCPSock
67 <      Left            =   3720
68 <      Top             =   1800
67 >      Left            =   4080
68 >      Top             =   4200
69        _ExtentX        =   741
70        _ExtentY        =   741
71        _Version        =   393216
72     End
73     Begin MSWinsockLib.Winsock UDPSock
74 <      Left            =   3240
75 <      Top             =   1800
74 >      Left            =   3600
75 >      Top             =   4200
76        _ExtentX        =   741
77        _ExtentY        =   741
78        _Version        =   393216
79        Protocol        =   1
80     End
81 <   Begin VB.Label Label5
82 <      Caption         =   "b e t a"
83 <      BeginProperty Font
84 <         Name            =   "MS Sans Serif"
85 <         Size            =   24
86 <         Charset         =   0
77 <         Weight          =   700
78 <         Underline       =   0   'False
79 <         Italic          =   0   'False
80 <         Strikethrough   =   0   'False
81 <      EndProperty
82 <      Height          =   615
83 <      Left            =   240
84 <      TabIndex        =   8
85 <      Top             =   120
86 <      Width           =   1815
81 >   Begin VB.Image Image1
82 >      Height          =   900
83 >      Left            =   2400
84 >      Picture         =   "nettest.frx":0742
85 >      Top             =   90
86 >      Width           =   2100
87     End
88     Begin VB.Label Label2
89        Alignment       =   1  'Right Justify
90        Caption         =   "Next heartbeat:"
91        Height          =   255
92 <      Left            =   2400
93 <      TabIndex        =   6
94 <      Top             =   480
92 >      Left            =   120
93 >      TabIndex        =   5
94 >      Top             =   645
95        Width           =   1455
96     End
97     Begin VB.Label Label1
98        Alignment       =   1  'Right Justify
99        Caption         =   "Next UDP packet:"
100        Height          =   255
101 <      Left            =   2400
102 <      TabIndex        =   5
103 <      Top             =   120
101 >      Left            =   120
102 >      TabIndex        =   4
103 >      Top             =   165
104        Width           =   1455
105     End
106     Begin VB.Label Label4
107        BorderStyle     =   1  'Fixed Single
108        Caption         =   "0"
109        Height          =   255
110 <      Left            =   3960
111 <      TabIndex        =   4
112 <      Top             =   480
110 >      Left            =   1680
111 >      TabIndex        =   3
112 >      Top             =   645
113        Width           =   615
114     End
115     Begin VB.Label Label3
116        BorderStyle     =   1  'Fixed Single
117        Caption         =   "0"
118        Height          =   255
119 <      Left            =   3960
120 <      TabIndex        =   3
121 <      Top             =   120
119 >      Left            =   1680
120 >      TabIndex        =   2
121 >      Top             =   165
122        Width           =   615
123     End
124     Begin VB.Label Status
# Line 126 | Line 126 | Begin VB.Form Form1
126        Caption         =   "Status:"
127        Height          =   255
128        Left            =   0
129 <      TabIndex        =   2
130 <      Top             =   1320
131 <      Width           =   4695
129 >      TabIndex        =   1
130 >      Top             =   1035
131 >      Width           =   3180
132     End
133   End
134   Attribute VB_Name = "Form1"
# Line 146 | Line 146 | Dim filterManagerTCPPort As Long
146   Dim seqNo As Long
147   Dim machineName As String
148  
149 + Dim secondsRunning As Long
150 +
151   Dim filterHostname As String
152   Dim filterTCPPort As Integer
153   Dim filterUDPPort As Integer
154   Dim fileList As String
155   Dim lastModified As String
156  
157 + Dim fourtySevenDays As Integer
158 +
159   Dim UDPUpdateTime As Integer
160   Dim TCPUpdateTime As Integer
161  
162   Dim protocolVersion As String
163   Dim connected As Boolean
164 + Dim heartBeating As Boolean
165  
166 < 'Dim CUpTime As New CUpTime
166 > Dim CUpTime As New CUpTime
167 > Dim wksta As New CNetWksta
168  
169 + Dim windowBig As Boolean
170 +
171   Dim responseNumber As Integer
172  
173 + Private Sub Command1_Click()
174 +
175 +    ' Toggle visibility of the debug output.
176 +
177 +    If windowBig Then
178 +        Form1.Height = 1755
179 +        windowBig = False
180 +    Else
181 +        Form1.Height = 4380
182 +        windowBig = True
183 +    End If
184 +
185 + End Sub
186 +
187   Private Sub Form_Load()
188      
189 +    If App.PrevInstance Then
190 +        x = MsgBox("There is already an i-scream Winhost running on this machine.", 48, "i-scream host already running")
191 +        End
192 +    End If
193 +    
194 +    ' Assume the host is run within the first 47 days of the machine starting.
195 +    fourtySevenDays = 0
196 +    
197      protocolVersion = "1.1"
198      
199      Status.Caption = "Loading"
200 <    'Form1.Caption = "i-scream Winhost " & protocolVersion & " for " & GetVersion()
200 >    Form1.Caption = "i-scream Winhost " & protocolVersion
201      
202 +    CUpTime.Init
203 +    
204 +    If CUpTime.isWin9x Then
205 +        x = MsgBox("Sorry, the i-scream host can only be used to monitor servers (i.e. not Win9x)", 48, "Not a server")
206 +        End
207 +    End If
208 +    
209 +    windowBig = False
210 +    
211      ''''TEMP
212      'filterManagerHostname = "killigrew.ukc.ac.uk"
213      'filterManagerTCPPort = 4567
# Line 182 | Line 221 | Private Sub Form_Load()
221      filterManagerHostname = Left$(buf, length)
222      length = GetPrivateProfileInt("i-scream Winhost", "FilterManagerPort", 0, App.Path & "/winhost.ini")
223      filterManagerTCPPort = length
224 +    If filterManagerHostname = "" Then
225 +        GoTo iniError
226 +    End If
227 +    On Error GoTo 0
228   skip:
229  
230      Status.Caption = "Connecting to Filter Manager " & filterManagerHostname & ":" & filterManagerTCPPort
231      Reconfigure_Click
232      
233 <    Form1.Show
233 >    SystemTray.Icon = Val(Form1.Icon)
234      SystemTray.Action = 0
235      
236      
# Line 214 | Line 257 | Private Sub Hide_Click()
257      SystemTray.Icon = Val(Form1.Icon)
258   End Sub
259  
260 +
261   Private Sub Reconfigure_Click()
262      ' establish a TCP connection to a filtermanager
263 <    connected = False
264 <    TCPSock.Close
265 <    TCPSock.Connect filterManagerHostname, filterManagerTCPPort
263 >    If Not heartBeating Then
264 >        connected = False
265 >        TCPSock.Close
266 >        TCPSock.Connect filterManagerHostname, filterManagerTCPPort
267 >    Else
268 >        Status.Caption = "Cannot reconfigure while heartbeating"
269 >    End If
270   End Sub
271  
272  
# Line 227 | Line 275 | Private Sub SystemTray_MouseDblClk(ByVal Button As Int
275  
276      Form1.Visible = True
277      Form1.SetFocus
230    
278  
279   End Sub
280  
# Line 256 | Line 303 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
303      ' Remove linefeeds and returns from the line.
304      response = Replace(response, Chr(13), "")
305      response = Replace(response, Chr(10), "")
259    Text4.Text = Text4.Text & vbCrLf & response
306      
307      If connected = False Then
308          ' Perform TCP configuration (1.1)
# Line 265 | Line 311 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
311              Case 1:
312                  If Not response = "OK" Then GoTo configError
313                  TCPSock.SendData "LASTMODIFIED" & vbCrLf
314 +                Text1.Text = "Requesting configuration from FilterManager:- " & vbCrLf
315 +                Text1.Text = Text1.Text & response & vbCrLf
316              Case 2:
317                  If response = "ERROR" Then GoTo configError
318                  lastModified = response
319 +                Text1.Text = Text1.Text & response & vbCrLf
320                  TCPSock.SendData "FILELIST" & vbCrLf
321 +            ' New addition to the protocol.
322              Case 3:
323                  If response = "ERROR" Then GoTo configError
324                  fileList = response
325 <                TCPSock.SendData "UDPUpdateTime" & vbCrLf
325 >                Text1.Text = Text1.Text & response & vbCrLf
326 >                TCPSock.SendData "FQDN" & vbCrLf
327              Case 4:
328                  If response = "ERROR" Then GoTo configError
329 +                Text1.Text = Text1.Text & response & vbCrLf
330 +                machineName = response
331 +                TCPSock.SendData "UDPUpdateTime" & vbCrLf
332 +            Case 5:
333 +                If response = "ERROR" Then GoTo configError
334                  UDPUpdateTime = response
335 +                Text1.Text = Text1.Text & response & vbCrLf
336                  TCPSock.SendData "TCPUpdateTime" & vbCrLf
337 <            Case 5:
337 >            Case 6:
338                  If response = "ERROR" Then GoTo configError
339                  TCPUpdateTime = response
340 +                Text1.Text = Text1.Text & response & vbCrLf
341                  TCPSock.SendData "ENDCONFIG" & vbCrLf
342 <            Case 6:
342 >            Case 7:
343                  If Not response = "OK" Then GoTo configError
344 +                Text1.Text = Text1.Text & response & vbCrLf
345                  TCPSock.SendData "FILTER" & vbCrLf
346 <            Case 7:
346 >            Case 8:
347 >                Text1.Text = Text1.Text & response & vbCrLf
348                  'we got a filter list here.
349                  readTo = 0
350                  ' get hostname
# Line 298 | Line 358 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
358                  ' get TCP Port number
359                  filterTCPPort = response
360                  TCPSock.SendData "END" & vbCrLf
361 <            Case 8:
361 >            Case 9:
362                  If Not response = "OK" Then GoTo configError
363                  connected = True
364                  responseNumber = 0
365                  TCPSock.Close
366 <                Text4.Text = Text4.Text & vbCrLf & "  <closed>"
366 >                Text1.Text = Text1.Text & response & vbCrLf
367 >                'Text4.Text = Text4.Text & vbCrLf & "  <closed>"
368                  Status.Caption = "Configuration successful"
369                  Label3.Caption = UDPUpdateTime
370                  Label4.Caption = TCPUpdateTime
# Line 311 | Line 372 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
372          End Select
373      Else
374          ' Perform a heartbeat (1.1)
375 +        heartBeating = True
376          On Error GoTo heartbeatError
377          Select Case responseNumber
378              Case 1:
379                  If Not response = "OK" Then GoTo heartbeatError
380 +                Text1.Text = "Performing heartbeat: -" & vbCrLf
381 +                Text1.Text = Text1.Text & response & vbCrLf
382                  TCPSock.SendData "CONFIG" & vbCrLf
383              Case 2:
384                  If Not response = "OK" Then GoTo heartbeatError
385 +                Text1.Text = Text1.Text & response & vbCrLf
386                  TCPSock.SendData fileList & vbCrLf
387              Case 3:
388                  If Not response = "OK" Then GoTo heartbeatError
389 +                Text1.Text = Text1.Text & response & vbCrLf
390                  TCPSock.SendData lastModified & vbCrLf
391              Case 4:
392 <                If Not response = "OK" Then GoTo heartbeatError
392 >                If Not response = "OK" Then
393 >                    heartBeating = False
394 >                    Reconfigure_Click
395 >                End If
396 >                Text1.Text = Text1.Text & response & vbCrLf
397                  TCPSock.SendData "ENDHEARTBEAT" & vbCrLf
398              Case 5:
399                  If Not response = "OK" Then GoTo heartbeatError
400 +                Text1.Text = Text1.Text & response & vbCrLf
401                  TCPSock.Close
402                  Status.Caption = "Heartbeat sent successfully."
403          End Select
# Line 337 | Line 408 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
408      Exit Sub
409      
410   configError:
411 <    Status.Caption = "FAILED to get configuration"
411 >    heartBeating = False
412 >    Status.Caption = "FAILED to get configuration from the server"
413      Exit Sub
414   heartbeatError:
415 +    heartBeating = False
416      Status.Caption = "Heatbeat FAILED"
417      Exit Sub
418   End Sub
# Line 355 | Line 428 | Private Sub Timer1_Timer()
428          
429          ' prepare the contents of the XML packet.
430          seqNo = seqNo + 1
431 <        machineName = TCPSock.LocalHostName
431 >        
432 >        netbiosName = TCPSock.LocalHostName
433 >        
434          LocalIP = TCPSock.LocalIP
435          packetDate = Date2Num()
436          
# Line 368 | Line 443 | Private Sub Timer1_Timer()
443              End
444          End If
445            
446 <        osName = getVersion()
446 >        osName = GetVersion()
447          osVersionMajor = verinfo.dwMajorVersion
448          osVersionMinor = verinfo.dwMinorVersion
449          osBuild = verinfo.dwBuildNumber
# Line 394 | Line 469 | Private Sub Timer1_Timer()
469          Dim memory&
470          GlobalMemoryStatus memsts
471          memory& = memsts.dwTotalPhys
472 <        memTotal = memory& \ 1024
472 >        memTotal = memory& \ 1048576
473          memory& = memsts.dwAvailPhys
474 <        memFree = memory& \ 1024
474 >        memFree = memory& \ 1048576
475          memory& = memsts.dwTotalVirtual
476 <        swapTotal = memory& \ 1024
476 >        swapTotal = memory& \ 1048576
477          memory& = memsts.dwAvailVirtual
478 <        swapFree = memory& \ 1024
478 >        swapFree = memory& \ 1048576
479          
480 +        CUpTime.Capture
481 +        cpu_time = CUpTime.CPUTime
482 +        percent_idle = CUpTime.PercentIdle
483 +        
484 +        '' Doesn't work after 47 days :-/
485 +        'uptime = GetTickCount \ 1000
486 +        
487 +        'secondsRunning = secondsRunning + UDPUpdateTime
488 +        'uptime = secondsRunning
489 +        
490 +        uptime = CUpTime.MilliSecs / 1000#
491 +        
492 +        userCount = wksta.LoggedOnUsers
493 +        
494          ' build the contents of the XML packet
495          xml = "<packet seq_no=""" & seqNo & """ machine_name=""" & machineName & """ date=""" & packetDate & """ type=""data"" ip=""" & LocalIP & """>" & _
496                "<os>" & _
497 +                "<netbios_name>" & netbiosName & "</netbios_name>" & _
498                  "<name>" & osName & "</name>" & _
499 <                "<version>" & osVersionMajor & "</version>" & _
499 >                "<version>" & osVersionMajor & "." & osVersionMinor & "</version>" & _
500                  "<release>" & osBuild & "</release>" & _
501 <                "<platform>" & osName & "</platform>" & _
502 <                "<minor_version>" & osVersionMinor & "</minor_version>" & _
413 <                "<processor>" & processorType & "</processor>" & _
501 >                "<platform>" & processorType & "</platform>" & _
502 >                "<uptime>" & uptime & "</uptime>" & _
503                "</os>" & _
504 +              "<users><count>" & userCount & "</count></users>" & _
505 +              "<cpu><idle>" & percent_idle & "</idle><user>" & cpu_time & "</user></cpu>" & _
506                "<memory><total>" & memTotal & "</total><free>" & memFree & "</free></memory>" & _
507                "<swap><total>" & swapTotal & "</total><free>" & swapFree & "</free></swap>" & _
508                "</packet>"
509 <        Text4.Text = Text4.Text + xml
509 >        Text1.Text = "Last packet contained: -" & vbCrLf & xml
510  
511          ' Use the first winsock control to send a UDP packet.
512          UDPSock.RemoteHost = filterHostname

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines