ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/projects/cms/source/host/winhost/nettest.frm
(Generate patch)

Comparing projects/cms/source/host/winhost/nettest.frm (file contents):
Revision 1.1 by pjm2, Thu Feb 22 17:04:22 2001 UTC vs.
Revision 1.36 by pjm2, Mon Mar 19 10:11:15 2001 UTC

# Line 1 | Line 1
1   VERSION 5.00
2   Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX"
3 + Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0"; "SysTray.ocx"
4   Begin VB.Form Form1
5     BorderStyle     =   3  'Fixed Dialog
6 <   Caption         =   "TCP/UDP Test program"
7 <   ClientHeight    =   5655
6 >   Caption         =   "i-scream Winhost"
7 >   ClientHeight    =   1185
8     ClientLeft      =   45
9     ClientTop       =   330
10 <   ClientWidth     =   5670
10 >   ClientWidth     =   4710
11 >   Icon            =   "nettest.frx":0000
12     LinkTopic       =   "Form1"
13     MaxButton       =   0   'False
14     MinButton       =   0   'False
15 <   ScaleHeight     =   5655
16 <   ScaleWidth      =   5670
15 >   ScaleHeight     =   1185
16 >   ScaleWidth      =   4710
17     ShowInTaskbar   =   0   'False
18 <   StartUpPosition =   3  'Windows Default
19 <   Begin VB.CommandButton Command3
20 <      Caption         =   "TCP to Filter"
21 <      Height          =   375
22 <      Left            =   3720
23 <      TabIndex        =   9
24 <      Top             =   2520
25 <      Width           =   1575
18 >   StartUpPosition =   2  'CenterScreen
19 >   Visible         =   0   'False
20 >   Begin VB.CommandButton Command1
21 >      Caption         =   "more"
22 >      Height          =   255
23 >      Left            =   3960
24 >      TabIndex        =   8
25 >      Top             =   840
26 >      Width           =   615
27     End
28 <   Begin VB.TextBox Text4
29 <      Height          =   2535
30 <      Left            =   240
28 >   Begin VB.TextBox Text1
29 >      Height          =   2055
30 >      Left            =   120
31 >      Locked          =   -1  'True
32        MultiLine       =   -1  'True
33        ScrollBars      =   2  'Vertical
30      TabIndex        =   8
31      Text            =   "nettest.frx":0000
32      Top             =   3000
33      Width           =   5055
34   End
35   Begin VB.CommandButton Command2
36      Caption         =   "TCP to FilterManager"
37      Height          =   375
38      Left            =   3360
34        TabIndex        =   7
35 <      Top             =   2040
36 <      Width           =   1935
35 >      Top             =   1200
36 >      Width           =   4455
37     End
38 <   Begin MSWinsockLib.Winsock Winsock2
39 <      Left            =   4920
40 <      Top             =   120
41 <      _ExtentX        =   741
42 <      _ExtentY        =   741
43 <      _Version        =   393216
38 >   Begin VB.CommandButton Hide
39 >      Caption         =   "hide"
40 >      Height          =   255
41 >      Left            =   3960
42 >      TabIndex        =   6
43 >      Top             =   480
44 >      Width           =   615
45     End
46 <   Begin VB.TextBox Text3
47 <      Height          =   285
48 <      Left            =   1680
49 <      TabIndex        =   5
50 <      Text            =   "killigrew.ukc.ac.uk"
51 <      Top             =   1560
52 <      Width           =   2535
46 >   Begin SysTray.SystemTray SystemTray
47 >      Left            =   2520
48 >      Top             =   4200
49 >      _ExtentX        =   847
50 >      _ExtentY        =   847
51 >      SysTrayText     =   "i-scream Winhost"
52 >      IconFile        =   0
53     End
54 <   Begin VB.TextBox Text2
55 <      Height          =   285
56 <      Left            =   1680
61 <      TabIndex        =   3
62 <      Text            =   "4567"
63 <      Top             =   1920
64 <      Width           =   855
54 >   Begin VB.Timer Timer1
55 >      Left            =   3120
56 >      Top             =   4200
57     End
58 <   Begin VB.CommandButton Command1
59 <      Caption         =   "Send UDP"
58 >   Begin VB.CommandButton Reconfigure
59 >      Caption         =   "Reconfigure with FilterManager"
60        Height          =   375
61 <      Left            =   4320
70 <      TabIndex        =   2
71 <      Top             =   1560
72 <      Width           =   975
73 <   End
74 <   Begin VB.TextBox Text1
75 <      Height          =   855
76 <      Left            =   360
61 >      Left            =   840
62        TabIndex        =   0
63 <      Text            =   "<packet></packet>"
64 <      Top             =   600
80 <      Width           =   4935
63 >      Top             =   3480
64 >      Width           =   2895
65     End
66 <   Begin MSWinsockLib.Winsock Winsock1
67 <      Left            =   4320
68 <      Top             =   120
66 >   Begin MSWinsockLib.Winsock TCPSock
67 >      Left            =   4080
68 >      Top             =   4200
69        _ExtentX        =   741
70        _ExtentY        =   741
71        _Version        =   393216
72 +   End
73 +   Begin MSWinsockLib.Winsock UDPSock
74 +      Left            =   3600
75 +      Top             =   4200
76 +      _ExtentX        =   741
77 +      _ExtentY        =   741
78 +      _Version        =   393216
79        Protocol        =   1
80     End
81 <   Begin VB.Label Label3
81 >   Begin VB.Label Label2
82        Alignment       =   1  'Right Justify
83 <      Caption         =   "Destination:"
83 >      Caption         =   "Next heartbeat:"
84        Height          =   255
85 <      Left            =   360
86 <      TabIndex        =   6
87 <      Top             =   1560
88 <      Width           =   1215
85 >      Left            =   120
86 >      TabIndex        =   5
87 >      Top             =   480
88 >      Width           =   1455
89     End
90 <   Begin VB.Label Label2
90 >   Begin VB.Label Label1
91        Alignment       =   1  'Right Justify
92 <      Caption         =   "Port:"
92 >      Caption         =   "Next UDP packet:"
93        Height          =   255
94 <      Left            =   360
94 >      Left            =   120
95        TabIndex        =   4
96 <      Top             =   1920
97 <      Width           =   1215
96 >      Top             =   120
97 >      Width           =   1455
98     End
99 <   Begin VB.Label Label1
100 <      Caption         =   "Packet contents"
99 >   Begin VB.Label Label4
100 >      BorderStyle     =   1  'Fixed Single
101 >      Caption         =   "0"
102        Height          =   255
103 <      Left            =   360
103 >      Left            =   1680
104 >      TabIndex        =   3
105 >      Top             =   480
106 >      Width           =   615
107 >   End
108 >   Begin VB.Label Label3
109 >      BorderStyle     =   1  'Fixed Single
110 >      Caption         =   "0"
111 >      Height          =   255
112 >      Left            =   1680
113 >      TabIndex        =   2
114 >      Top             =   120
115 >      Width           =   615
116 >   End
117 >   Begin VB.Label Status
118 >      Alignment       =   2  'Center
119 >      Caption         =   "Status:"
120 >      Height          =   255
121 >      Left            =   0
122        TabIndex        =   1
123 <      Top             =   360
124 <      Width           =   2895
123 >      Top             =   840
124 >      Width           =   3855
125     End
126   End
127   Attribute VB_Name = "Form1"
# Line 119 | Line 129 | Attribute VB_GlobalNameSpace = False
129   Attribute VB_Creatable = False
130   Attribute VB_PredeclaredId = True
131   Attribute VB_Exposed = False
132 < Dim responseNumber As Integer
132 > ' For the system tray bits
133 > Private Declare Function GetPrivateProfileString Lib "kernel32" Alias "GetPrivateProfileStringA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal lpDefault As String, ByVal lpReturnedString As String, ByVal nSize As Long, ByVal lpFileName As String) As Long
134 > Private Declare Function GetPrivateProfileInt Lib "kernel32" Alias "GetPrivateProfileIntA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal nDefault As Long, ByVal lpFileName As String) As Long
135  
136 + Dim filterManagerHostname As String
137 + Dim filterManagerTCPPort As Long
138  
139 + Dim seqNo As Long
140 + Dim machineName As String
141 +
142 + Dim secondsRunning As Long
143 +
144 + Dim filterHostname As String
145 + Dim filterTCPPort As Integer
146 + Dim filterUDPPort As Integer
147 + Dim fileList As String
148 + Dim lastModified As String
149 +
150 + Dim fourtySevenDays As Integer
151 +
152 + Dim UDPUpdateTime As Integer
153 + Dim TCPUpdateTime As Integer
154 +
155 + Dim protocolVersion As String
156 + Dim connected As Boolean
157 + Dim heartBeating As Boolean
158 +
159 + Dim CUpTime As New CUpTime
160 + Dim wksta As New CNetWksta
161 +
162 + Dim windowBig As Boolean
163 +
164 + Dim responseNumber As Integer
165 +
166   Private Sub Command1_Click()
167  
168 <    ' Use the first winsock control to send
128 <    ' a UDP packet.
129 <    Winsock1.RemoteHost = Text3.Text
130 <    Winsock1.RemotePort = Text2.Text
131 <    Winsock1.SendData Text1.Text
168 >    ' Toggle visibility of the debug output.
169  
170 +    If windowBig Then
171 +        Form1.Height = 1500
172 +        windowBig = False
173 +    Else
174 +        Form1.Height = 4350
175 +        windowBig = True
176 +    End If
177 +
178   End Sub
179  
180 < Private Sub Command2_Click()
180 > Private Sub Form_Load()
181      
182 <    ' establish a TCP connection to a machine
183 <    Winsock2.Close
184 <    Winsock2.Connect Text3.Text, Text2.Text
182 >    If App.PrevInstance Then
183 >        x = MsgBox("There is already an i-scream Winhost running on this machine.", 48, "i-scream host already running")
184 >        End
185 >    End If
186 >    
187 >    ' Assume the host is run within the first 47 days of the machine starting.
188 >    fourtySevenDays = 0
189 >    
190 >    protocolVersion = "1.1"
191 >    
192 >    Status.Caption = "Loading"
193 >    Form1.Caption = "i-scream Winhost " & protocolVersion
194 >    
195 >    CUpTime.Init
196 >    
197 >    If CUpTime.isWin9x Then
198 >        x = MsgBox("Sorry, the i-scream host can only be used to monitor servers (i.e. not Win9x)", 48, "Not a server")
199 >        End
200 >    End If
201 >    
202 >    windowBig = False
203 >    
204 >    ''''TEMP
205 >    'filterManagerHostname = "killigrew.ukc.ac.uk"
206 >    'filterManagerTCPPort = 4567
207 >    ''''' END TEMP
208 >    
209 >    'GoTo skip
210 >    On Error GoTo iniError
211 >    Dim buf As String * 256
212 >    Dim length As Long
213 >    length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "<no value>", buf, Len(buf), App.Path & "/winhost.ini")
214 >    filterManagerHostname = Left$(buf, length)
215 >    length = GetPrivateProfileInt("i-scream Winhost", "FilterManagerPort", 0, App.Path & "/winhost.ini")
216 >    filterManagerTCPPort = length
217 >    If filterManagerHostname = "" Then
218 >        GoTo iniError
219 >    End If
220 >    On Error GoTo 0
221 > skip:
222  
223 +    Status.Caption = "Connecting to Filter Manager " & filterManagerHostname & ":" & filterManagerTCPPort
224 +    Reconfigure_Click
225 +    
226 +    SystemTray.Icon = Val(Form1.Icon)
227 +    SystemTray.Action = 0
228 +    
229 +    
230 +    Exit Sub
231 +    
232 + iniError:
233 +    x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file.  Please correct these and try again.  " & Err.Description, 48, "Configuration not found")
234 +    End
235 +    
236   End Sub
237  
238 < Private Sub Command3_Click()
239 <    x = MsgBox("not implemented..")
238 > Private Sub Form_QueryUnload(Cancel As Integer, UnloadMode As Integer)
239 >    x = MsgBox("Are you sure you want to shut down the Winhost?  This will stop your computer sending information to the i-scream Central Monitoring System.", vbYesNo, "i-scream Winhost")
240 >    If x = 7 Then
241 >        Cancel = True
242 >    Else
243 >        SystemTray.Action = 2
244 >    End If
245 >
246   End Sub
247  
248 < Private Sub Winsock2_Connect()
249 <      
250 <   responseNumber = 0
248 > Private Sub Hide_Click()
249 >    Form1.Visible = False
250 >    SystemTray.Icon = Val(Form1.Icon)
251 > End Sub
252 >
253 >
254 > Private Sub Reconfigure_Click()
255 >    ' establish a TCP connection to a filtermanager
256 >    If Not heartBeating Then
257 >        connected = False
258 >        TCPSock.Close
259 >        TCPSock.Connect filterManagerHostname, filterManagerTCPPort
260 >    Else
261 >        Status.Caption = "Cannot reconfigure while heartbeating"
262 >    End If
263 > End Sub
264 >
265 >
266 >
267 > Private Sub SystemTray_MouseDblClk(ByVal Button As Integer)
268 >
269 >    Form1.Visible = True
270 >    Form1.SetFocus
271 >
272 > End Sub
273 >
274 > Private Sub TCPSock_Connect()
275 >    
276 >    responseNumber = 0
277    
278 <   ' As soon as we are connected to the server, send this.
279 <   Winsock2.SendData "STARTCONFIG" & vbCrLf
278 >    ' Send something as soon as we connect to the server.
279 >    If connected = False Then
280 >        ' contact the FilterManager
281 >        TCPSock.SendData "STARTCONFIG" & vbCrLf
282 >    Else
283 >       ' Contact the Filter
284 >       TCPSock.SendData "HEARTBEAT" & vbCrLf
285 >    End If
286    
287   End Sub
288  
289 < Private Sub Winsock2_DataArrival(ByVal bytesTotal As Long)
289 > Private Sub TCPSock_DataArrival(ByVal bytesTotal As Long)
290      
291      responseNumber = responseNumber + 1
292      
293      ' Get the line from the server.
294 <    Winsock2.GetData response, vbString, bytesTotal
294 >    TCPSock.GetData response, vbString, bytesTotal
295      
296      ' Remove linefeeds and returns from the line.
297      response = Replace(response, Chr(13), "")
298      response = Replace(response, Chr(10), "")
166    Text4.Text = Text4.Text & vbCrLf & response
299      
300 <    ' Decide what to send back to the server.
301 <    Select Case responseNumber
302 <        Case 1:
303 <            Winsock2.SendData "LASTMODIFIED" & vbCrLf
304 <        Case 2:
305 <            Winsock2.SendData "FILELIST" & vbCrLf
306 <        Case 3:
307 <            Winsock2.SendData "UDPUpdateTime" & vbCrLf
308 <        Case 4:
309 <            Winsock2.SendData "TCPUpdateTime" & vbCrLf
310 <        Case 5:
311 <            Winsock2.SendData "ENDCONFIG" & vbCrLf
312 <        Case 6:
313 <            Winsock2.SendData "FILTER" & vbCrLf
314 <        Case 7:
315 <            Winsock2.SendData "END" & vbCrLf
316 <        Case 8:
317 <            Winsock2.Close
318 <            Text4.Text = Text4.Text & vbCrLf & "  <closed>"
319 <    End Select
300 >    If connected = False Then
301 >        ' Perform TCP configuration (1.1)
302 >        On Error GoTo configError
303 >        Select Case responseNumber
304 >            Case 1:
305 >                If Not response = "OK" Then GoTo configError
306 >                TCPSock.SendData "LASTMODIFIED" & vbCrLf
307 >                Text1.Text = "Requesting configuration from FilterManager:- " & vbCrLf
308 >                Text1.Text = Text1.Text & response & vbCrLf
309 >            Case 2:
310 >                If response = "ERROR" Then GoTo configError
311 >                lastModified = response
312 >                Text1.Text = Text1.Text & response & vbCrLf
313 >                TCPSock.SendData "FILELIST" & vbCrLf
314 >            ' New addition to the protocol.
315 >            Case 3:
316 >                If response = "ERROR" Then GoTo configError
317 >                fileList = response
318 >                Text1.Text = Text1.Text & response & vbCrLf
319 >                TCPSock.SendData "FQDN" & vbCrLf
320 >            Case 4:
321 >                If response = "ERROR" Then GoTo configError
322 >                Text1.Text = Text1.Text & response & vbCrLf
323 >                machineName = response
324 >                TCPSock.SendData "UDPUpdateTime" & vbCrLf
325 >            Case 5:
326 >                If response = "ERROR" Then GoTo configError
327 >                UDPUpdateTime = response
328 >                Text1.Text = Text1.Text & response & vbCrLf
329 >                TCPSock.SendData "TCPUpdateTime" & vbCrLf
330 >            Case 6:
331 >                If response = "ERROR" Then GoTo configError
332 >                TCPUpdateTime = response
333 >                Text1.Text = Text1.Text & response & vbCrLf
334 >                TCPSock.SendData "ENDCONFIG" & vbCrLf
335 >            Case 7:
336 >                If Not response = "OK" Then GoTo configError
337 >                Text1.Text = Text1.Text & response & vbCrLf
338 >                TCPSock.SendData "FILTER" & vbCrLf
339 >            Case 8:
340 >                Text1.Text = Text1.Text & response & vbCrLf
341 >                'we got a filter list here.
342 >                readTo = 0
343 >                ' get hostname
344 >                readTo = InStr(1, response, ";", vbBinaryCompare)
345 >                filterHostname = Mid(response, 1, readTo - 1)
346 >                response = Mid(response, readTo + 1, Len(response))
347 >                ' get UDP Port number
348 >                readTo = InStr(1, response, ";")
349 >                filterUDPPort = Mid(response, 1, readTo - 1)
350 >                response = Mid(response, readTo + 1, Len(response))
351 >                ' get TCP Port number
352 >                filterTCPPort = response
353 >                TCPSock.SendData "END" & vbCrLf
354 >            Case 9:
355 >                If Not response = "OK" Then GoTo configError
356 >                connected = True
357 >                responseNumber = 0
358 >                TCPSock.Close
359 >                Text1.Text = Text1.Text & response & vbCrLf
360 >                'Text4.Text = Text4.Text & vbCrLf & "  <closed>"
361 >                Status.Caption = "Configuration successful"
362 >                Label3.Caption = UDPUpdateTime
363 >                Label4.Caption = TCPUpdateTime
364 >                Timer1.Interval = 1000
365 >        End Select
366 >    Else
367 >        ' Perform a heartbeat (1.1)
368 >        heartBeating = True
369 >        On Error GoTo heartbeatError
370 >        Select Case responseNumber
371 >            Case 1:
372 >                If Not response = "OK" Then GoTo heartbeatError
373 >                Text1.Text = "Performing heartbeat: -" & vbCrLf
374 >                Text1.Text = Text1.Text & response & vbCrLf
375 >                TCPSock.SendData "CONFIG" & vbCrLf
376 >            Case 2:
377 >                If Not response = "OK" Then GoTo heartbeatError
378 >                Text1.Text = Text1.Text & response & vbCrLf
379 >                TCPSock.SendData fileList & vbCrLf
380 >            Case 3:
381 >                If Not response = "OK" Then GoTo heartbeatError
382 >                Text1.Text = Text1.Text & response & vbCrLf
383 >                TCPSock.SendData lastModified & vbCrLf
384 >            Case 4:
385 >                If Not response = "OK" Then
386 >                    heartBeating = False
387 >                    Reconfigure_Click
388 >                End If
389 >                Text1.Text = Text1.Text & response & vbCrLf
390 >                TCPSock.SendData "ENDHEARTBEAT" & vbCrLf
391 >            Case 5:
392 >                If Not response = "OK" Then GoTo heartbeatError
393 >                Text1.Text = Text1.Text & response & vbCrLf
394 >                TCPSock.Close
395 >                Status.Caption = "Heartbeat sent successfully."
396 >        End Select
397      
398 +    End If
399 +    
400 +    
401 +    Exit Sub
402 +    
403 + configError:
404 +    heartBeating = False
405 +    Status.Caption = "FAILED to get configuration from the server"
406 +    Exit Sub
407 + heartbeatError:
408 +    heartBeating = False
409 +    Status.Caption = "Heatbeat FAILED"
410 +    Exit Sub
411   End Sub
412 +
413 + Private Sub Timer1_Timer()
414 +
415 +    Label3.Caption = Label3.Caption - 1
416 +    Label4.Caption = Label4.Caption - 1
417 +    
418 +    Status.Caption = ""
419 +    
420 +    If Label3.Caption < 1 Then
421 +        
422 +        ' prepare the contents of the XML packet.
423 +        seqNo = seqNo + 1
424 +        
425 +        netbiosName = TCPSock.LocalHostName
426 +        
427 +        LocalIP = TCPSock.LocalIP
428 +        packetDate = Date2Num()
429 +        
430 +        
431 +        Dim verinfo As OSVERSIONINFO
432 +        verinfo.dwOSVersionInfoSize = Len(verinfo)
433 +        ret% = GetVersionEx(verinfo)
434 +        If ret% = 0 Then
435 +            MsgBox "Error getting Windows version Information"
436 +            End
437 +        End If
438 +          
439 +        osName = GetVersion()
440 +        osVersionMajor = verinfo.dwMajorVersion
441 +        osVersionMinor = verinfo.dwMinorVersion
442 +        osBuild = verinfo.dwBuildNumber
443 +        
444 +        Dim sysinfo As SYSTEM_INFO
445 +        GetSystemInfo sysinfo
446 +        Select Case sysinfo.dwProcessorType
447 +            Case PROCESSOR_INTEL_386
448 +                processorType = "Intel 386"
449 +            Case PROCESSOR_INTEL_486
450 +                processorType = "Intel 486"
451 +            Case PROCESSOR_INTEL_PENTIUM
452 +                processorType = "Intel Pentium variant"
453 +            Case PROCESSOR_MIPS_R4000
454 +                processorType = "MIPS R4000"
455 +            Case PROCESSOR_ALPHA_21064
456 +                processorType = "DEC Alpha 21064"
457 +            Case Else
458 +                processorType = "(unknown)"
459 +        End Select
460 +        
461 +        Dim memsts As MEMORYSTATUS
462 +        Dim memory&
463 +        GlobalMemoryStatus memsts
464 +        memory& = memsts.dwTotalPhys
465 +        memTotal = memory& \ 1048576
466 +        memory& = memsts.dwAvailPhys
467 +        memFree = memory& \ 1048576
468 +        memory& = memsts.dwTotalVirtual
469 +        swapTotal = memory& \ 1048576
470 +        memory& = memsts.dwAvailVirtual
471 +        swapFree = memory& \ 1048576
472 +        
473 +        CUpTime.Capture
474 +        cpu_time = CUpTime.CPUTime
475 +        percent_idle = CUpTime.PercentIdle
476 +        
477 +        '' Doesn't work after 47 days :-/
478 +        'uptime = GetTickCount \ 1000
479 +        
480 +        'secondsRunning = secondsRunning + UDPUpdateTime
481 +        'uptime = secondsRunning
482 +        
483 +        uptime = CUpTime.MilliSecs / 1000#
484 +        
485 +        userCount = wksta.LoggedOnUsers
486 +        
487 +        ' build the contents of the XML packet
488 +        xml = "<packet seq_no=""" & seqNo & """ machine_name=""" & machineName & """ date=""" & packetDate & """ type=""data"" ip=""" & LocalIP & """>" & _
489 +              "<os>" & _
490 +                "<netbios_name>" & netbiosName & "</netbios_name>" & _
491 +                "<name>" & osName & "</name>" & _
492 +                "<version>" & osVersionMajor & "." & osVersionMinor & "</version>" & _
493 +                "<release>" & osBuild & "</release>" & _
494 +                "<platform>" & processorType & "</platform>" & _
495 +                "<uptime>" & uptime & "</uptime>" & _
496 +              "</os>" & _
497 +              "<users><count>" & userCount & "</count></users>" & _
498 +              "<cpu><idle>" & percent_idle & "</idle><user>" & cpu_time & "</user></cpu>" & _
499 +              "<memory><total>" & memTotal & "</total><free>" & memFree & "</free></memory>" & _
500 +              "<swap><total>" & swapTotal & "</total><free>" & swapFree & "</free></swap>" & _
501 +              "</packet>"
502 +        Text1.Text = "Last packet contained: -" & vbCrLf & xml
503 +
504 +        ' Use the first winsock control to send a UDP packet.
505 +        UDPSock.RemoteHost = filterHostname
506 +        UDPSock.RemotePort = filterUDPPort
507 +        UDPSock.SendData xml
508 +        Status.Caption = "UDP packet sent"
509 +        Label3.Caption = UDPUpdateTime
510 +    End If
511 +    
512 +    If Label4.Caption < 1 Then
513 +        ' establish a TCP connection to a filter
514 +        TCPSock.Close
515 +        TCPSock.Connect filterHostname, filterTCPPort
516 +        Label4.Caption = TCPUpdateTime
517 +    End If
518 +
519 + End Sub
520 +
521 + Function Date2Num() As Long
522 +    Dim x As Long
523 +    x = DateDiff("s", "1-1-1970", Now)
524 +    Date2Num = x
525 + End Function

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines