ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/projects/cms/source/host/winhost/nettest.frm
(Generate patch)

Comparing projects/cms/source/host/winhost/nettest.frm (file contents):
Revision 1.6 by pjm2, Fri Feb 23 10:53:30 2001 UTC vs.
Revision 1.10 by pjm2, Fri Feb 23 11:42:06 2001 UTC

# Line 1 | Line 1
1   VERSION 5.00
2   Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX"
3   Begin VB.Form Form1
4 <   BorderStyle     =   3  'Fixed Dialog
5 <   Caption         =   "TCP/UDP Test program"
4 >   BorderStyle     =   4  'Fixed ToolWindow
5 >   Caption         =   "i-scream Winhost"
6     ClientHeight    =   5655
7     ClientLeft      =   45
8 <   ClientTop       =   330
8 >   ClientTop       =   285
9     ClientWidth     =   5670
10     LinkTopic       =   "Form1"
11     MaxButton       =   0   'False
# Line 14 | Line 14 | Begin VB.Form Form1
14     ScaleWidth      =   5670
15     ShowInTaskbar   =   0   'False
16     StartUpPosition =   3  'Windows Default
17 <   Begin VB.CommandButton Command3
18 <      Caption         =   "TCP to Filter"
19 <      Height          =   375
20 <      Left            =   3720
21 <      TabIndex        =   3
22 <      Top             =   2520
23 <      Width           =   1575
17 >   Begin VB.Timer Timer1
18 >      Left            =   4200
19 >      Top             =   1200
20     End
21     Begin VB.TextBox Text4
22        Height          =   1575
23        Left            =   240
24        MultiLine       =   -1  'True
25        ScrollBars      =   2  'Vertical
26 <      TabIndex        =   2
26 >      TabIndex        =   1
27        Text            =   "nettest.frx":0000
28        Top             =   3000
29        Width           =   5055
30     End
31 <   Begin VB.CommandButton Command2
32 <      Caption         =   "TCP to FilterManager"
33 <      Height          =   375
34 <      Left            =   3360
35 <      TabIndex        =   1
36 <      Top             =   2040
37 <      Width           =   1935
31 >   Begin VB.CommandButton Reconfigure
32 >      Caption         =   "Reconfigure with FilterManager"
33 >      Height          =   495
34 >      Left            =   120
35 >      TabIndex        =   0
36 >      Top             =   120
37 >      Width           =   2895
38     End
39     Begin MSWinsockLib.Winsock TCPSock
40 <      Left            =   4920
41 <      Top             =   120
40 >      Left            =   5160
41 >      Top             =   1200
42        _ExtentX        =   741
43        _ExtentY        =   741
44        _Version        =   393216
45     End
50   Begin VB.CommandButton Command1
51      Caption         =   "Send UDP"
52      Height          =   375
53      Left            =   4320
54      TabIndex        =   0
55      Top             =   1560
56      Width           =   975
57   End
46     Begin MSWinsockLib.Winsock UDPSock
47 <      Left            =   4320
48 <      Top             =   120
47 >      Left            =   4680
48 >      Top             =   1200
49        _ExtentX        =   741
50        _ExtentY        =   741
51        _Version        =   393216
52        Protocol        =   1
53     End
54 +   Begin VB.Label Label2
55 +      Alignment       =   1  'Right Justify
56 +      Caption         =   "Next heartbeat:"
57 +      Height          =   255
58 +      Left            =   3360
59 +      TabIndex        =   6
60 +      Top             =   480
61 +      Width           =   1455
62 +   End
63 +   Begin VB.Label Label1
64 +      Alignment       =   1  'Right Justify
65 +      Caption         =   "Next UDP packet:"
66 +      Height          =   255
67 +      Left            =   3360
68 +      TabIndex        =   5
69 +      Top             =   120
70 +      Width           =   1455
71 +   End
72 +   Begin VB.Label Label4
73 +      BorderStyle     =   1  'Fixed Single
74 +      Caption         =   "0"
75 +      Height          =   255
76 +      Left            =   4920
77 +      TabIndex        =   4
78 +      Top             =   480
79 +      Width           =   615
80 +   End
81 +   Begin VB.Label Label3
82 +      BorderStyle     =   1  'Fixed Single
83 +      Caption         =   "0"
84 +      Height          =   255
85 +      Left            =   4920
86 +      TabIndex        =   3
87 +      Top             =   120
88 +      Width           =   615
89 +   End
90     Begin VB.Label Status
91        Caption         =   "Status:"
92        Height          =   255
93        Left            =   120
94 <      TabIndex        =   4
95 <      Top             =   5280
94 >      TabIndex        =   2
95 >      Top             =   840
96        Width           =   5415
97     End
98   End
# Line 89 | Line 113 | Dim filterUDPPort As Integer
113   Dim fileList As String
114   Dim lastModified As String
115  
116 + Dim UDPUpdateTime As Integer
117 + Dim TCPUpdateTime As Integer
118 +
119   Dim protocolVersion As String
120   Dim connected As Boolean
121   Dim responseNumber As Integer
# Line 107 | Line 134 | Private Sub Command1_Click()
134  
135   End Sub
136  
110 Private Sub Command2_Click()
111    
112    ' establish a TCP connection to a filtermanager
113    TCPSock.Close
114    TCPSock.Connect filterManagerHostname, filterManagerTCPPort
137  
116 End Sub
117
138   Private Sub Command3_Click()
139      ' establish a TCP connection to a filter
140      TCPSock.Close
# Line 123 | Line 143 | End Sub
143  
144   Private Sub Form_Load()
145      protocolVersion = "1.1"
146 +      
147 +    Status.Caption = "Loading"
148 +    Form1.Caption = "i-scream Winhost " & protocolVersion
149      
127    Status.Caption = "i-scream Winhost " & protocolVersion
128    
150      ''''TEMP
151      filterManagerHostname = "killigrew.ukc.ac.uk"
152      filterManagerTCPPort = 4567
153 +    Reconfigure_Click
154      Exit Sub
155      ''' ENDTEMP
156      
# Line 140 | Line 162 | Private Sub Form_Load()
162      length = GetPrivateProfileString("i-scream Winhost", "FilterManagerPort", "<no value>", buf, Len(buf), App.Path & "winhost.ini")
163      filterManagerTCPPort = Left$(buf, length)
164      
165 <    Status.Caption = "i-scream Winhost " & protocolVersion & " connecting to Filter Manager"
165 >    Status.Caption = "Connecting to Filter Manager"
166      
167      Exit Sub
168      
# Line 150 | Line 172 | iniError:
172      
173   End Sub
174  
175 < Private Sub Label1_Click()
175 > Private Sub Form_QueryUnload(Cancel As Integer, UnloadMode As Integer)
176 >    x = MsgBox("Are you sure you want to shut down the Winhost?", vbYesNo, "i-scream Winhost")
177 >    If x = 7 Then
178 >        Cancel = True
179 >    End If
180  
181   End Sub
182  
183 + Private Sub Reconfigure_Click()
184 +    ' establish a TCP connection to a filtermanager
185 +    connected = False
186 +    TCPSock.Close
187 +    TCPSock.Connect filterManagerHostname, filterManagerTCPPort
188 + End Sub
189 +
190   Private Sub TCPSock_Connect()
191      
192      responseNumber = 0
# Line 198 | Line 231 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
231                  TCPSock.SendData "UDPUpdateTime" & vbCrLf
232              Case 4:
233                  If response = "ERROR" Then GoTo configError
234 +                UDPUpdateTime = response
235                  TCPSock.SendData "TCPUpdateTime" & vbCrLf
236              Case 5:
237                  If response = "ERROR" Then GoTo configError
238 +                TCPUpdateTime = response
239                  TCPSock.SendData "ENDCONFIG" & vbCrLf
240              Case 6:
241                  If Not response = "OK" Then GoTo configError
# Line 225 | Line 260 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
260                  responseNumber = 0
261                  TCPSock.Close
262                  Text4.Text = Text4.Text & vbCrLf & "  <closed>"
263 <                Status.Caption = "i-scream Winhost " & protocolVersion & " - got config okay"
263 >                Status.Caption = "Configuration successful"
264 >                Label3.Caption = UDPUpdateTime
265 >                Label4.Caption = TCPUpdateTime
266 >                Timer1.Interval = 1000
267          End Select
268      Else
269          ' Perform a heartbeat (1.1)
# Line 246 | Line 284 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
284              Case 5:
285                  If Not response = "OK" Then GoTo heartbeatError
286                  TCPSock.Close
287 <                Status.Caption = "i-scream Winhost " & protocolVersion & " - heartbeat sent okay."
287 >                Status.Caption = "Heartbeat sent successfully."
288          End Select
289      
290      End If
# Line 255 | Line 293 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
293      Exit Sub
294      
295   configError:
296 <    Status.Caption = "i-scream Winhost " & protocolVersion & " - FAILED to get configuration"
296 >    Status.Caption = "FAILED to get configuration"
297 >    Exit Sub
298   heartbeatError:
299 <    Status.Caption = "i-scream Winhost " & protocolVersion & " - Heatbeat FAILED"
299 >    Status.Caption = "Heatbeat FAILED"
300 >    Exit Sub
301   End Sub
302  
303 + Private Sub Timer1_Timer()
304 +
305 +    Label3.Caption = Label3.Caption - 1
306 +    Label4.Caption = Label4.Caption - 1
307 +    
308 +    Status.Caption = ""
309 +    
310 +    If Label3.Caption < 1 Then
311 +        ' build the contents of the XML packet.
312 +        xml = "<packet></packet>"
313 +
314 +        ' Use the first winsock control to send a UDP packet.
315 +        UDPSock.RemoteHost = filterHostname
316 +        UDPSock.RemotePort = filterUDPPort
317 +        UDPSock.SendData xml
318 +        Status.Caption = "UDP packet sent"
319 +        Label3.Caption = UDPUpdateTime
320 +    End If
321 +    
322 +    If Label4.Caption < 1 Then
323 +        ' establish a TCP connection to a filter
324 +        TCPSock.Close
325 +        TCPSock.Connect filterHostname, filterTCPPort
326 +        Label4.Caption = TCPUpdateTime
327 +    End If
328 +
329 + End Sub

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines