ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/projects/cms/source/host/winhost/nettest.frm
(Generate patch)

Comparing projects/cms/source/host/winhost/nettest.frm (file contents):
Revision 1.2 by pjm2, Fri Feb 23 09:42:36 2001 UTC vs.
Revision 1.12 by pjm2, Fri Feb 23 12:01:14 2001 UTC

# Line 1 | Line 1
1   VERSION 5.00
2   Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX"
3 + Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0"; "SysTray.ocx"
4   Begin VB.Form Form1
5 <   BorderStyle     =   3  'Fixed Dialog
6 <   Caption         =   "TCP/UDP Test program"
5 >   BorderStyle     =   4  'Fixed ToolWindow
6 >   Caption         =   "i-scream Winhost"
7     ClientHeight    =   5655
8     ClientLeft      =   45
9 <   ClientTop       =   330
10 <   ClientWidth     =   5670
9 >   ClientTop       =   285
10 >   ClientWidth     =   4710
11     LinkTopic       =   "Form1"
12     MaxButton       =   0   'False
12   MinButton       =   0   'False
13     ScaleHeight     =   5655
14 <   ScaleWidth      =   5670
14 >   ScaleWidth      =   4710
15     ShowInTaskbar   =   0   'False
16     StartUpPosition =   3  'Windows Default
17 <   Begin VB.CommandButton Command3
18 <      Caption         =   "TCP to Filter"
17 >   Begin VB.CommandButton Hide
18 >      Caption         =   "Hide Window"
19        Height          =   375
20 <      Left            =   3720
21 <      TabIndex        =   9
22 <      Top             =   2520
23 <      Width           =   1575
20 >      Left            =   3120
21 >      TabIndex        =   7
22 >      Top             =   840
23 >      Width           =   1455
24     End
25 +   Begin SysTray.SystemTray SystemTray
26 +      Left            =   2160
27 +      Top             =   1800
28 +      _ExtentX        =   847
29 +      _ExtentY        =   847
30 +      SysTrayText     =   "i-scream Winhost"
31 +      IconFile        =   0
32 +   End
33 +   Begin VB.Timer Timer1
34 +      Left            =   2760
35 +      Top             =   1800
36 +   End
37     Begin VB.TextBox Text4
38 <      Height          =   2535
38 >      Height          =   1575
39        Left            =   240
40        MultiLine       =   -1  'True
41        ScrollBars      =   2  'Vertical
42 <      TabIndex        =   8
42 >      TabIndex        =   1
43        Text            =   "nettest.frx":0000
44        Top             =   3000
45 <      Width           =   5055
45 >      Width           =   3975
46     End
47 <   Begin VB.CommandButton Command2
48 <      Caption         =   "TCP to FilterManager"
47 >   Begin VB.CommandButton Reconfigure
48 >      Caption         =   "Reconfigure with FilterManager"
49        Height          =   375
50 <      Left            =   3360
51 <      TabIndex        =   7
52 <      Top             =   2040
53 <      Width           =   1935
50 >      Left            =   120
51 >      TabIndex        =   0
52 >      Top             =   840
53 >      Width           =   2895
54     End
55 <   Begin MSWinsockLib.Winsock Winsock2
56 <      Left            =   4920
57 <      Top             =   120
55 >   Begin MSWinsockLib.Winsock TCPSock
56 >      Left            =   3720
57 >      Top             =   1800
58        _ExtentX        =   741
59        _ExtentY        =   741
60        _Version        =   393216
61     End
62 <   Begin VB.TextBox Text3
63 <      Height          =   285
64 <      Left            =   1680
53 <      TabIndex        =   5
54 <      Text            =   "killigrew.ukc.ac.uk"
55 <      Top             =   1560
56 <      Width           =   2535
57 <   End
58 <   Begin VB.TextBox Text2
59 <      Height          =   285
60 <      Left            =   1680
61 <      TabIndex        =   3
62 <      Text            =   "4567"
63 <      Top             =   1920
64 <      Width           =   855
65 <   End
66 <   Begin VB.CommandButton Command1
67 <      Caption         =   "Send UDP"
68 <      Height          =   375
69 <      Left            =   4320
70 <      TabIndex        =   2
71 <      Top             =   1560
72 <      Width           =   975
73 <   End
74 <   Begin VB.TextBox Text1
75 <      Height          =   855
76 <      Left            =   360
77 <      TabIndex        =   0
78 <      Text            =   "<packet></packet>"
79 <      Top             =   600
80 <      Width           =   4935
81 <   End
82 <   Begin MSWinsockLib.Winsock Winsock1
83 <      Left            =   4320
84 <      Top             =   120
62 >   Begin MSWinsockLib.Winsock UDPSock
63 >      Left            =   3240
64 >      Top             =   1800
65        _ExtentX        =   741
66        _ExtentY        =   741
67        _Version        =   393216
68        Protocol        =   1
69     End
70 <   Begin VB.Label Label3
70 >   Begin VB.Label Label2
71        Alignment       =   1  'Right Justify
72 <      Caption         =   "Destination:"
72 >      Caption         =   "Next heartbeat:"
73        Height          =   255
74 <      Left            =   360
74 >      Left            =   2400
75        TabIndex        =   6
76 <      Top             =   1560
77 <      Width           =   1215
76 >      Top             =   480
77 >      Width           =   1455
78     End
79 <   Begin VB.Label Label2
79 >   Begin VB.Label Label1
80        Alignment       =   1  'Right Justify
81 <      Caption         =   "Port:"
81 >      Caption         =   "Next UDP packet:"
82        Height          =   255
83 <      Left            =   360
83 >      Left            =   2400
84 >      TabIndex        =   5
85 >      Top             =   120
86 >      Width           =   1455
87 >   End
88 >   Begin VB.Label Label4
89 >      BorderStyle     =   1  'Fixed Single
90 >      Caption         =   "0"
91 >      Height          =   255
92 >      Left            =   3960
93        TabIndex        =   4
94 <      Top             =   1920
95 <      Width           =   1215
94 >      Top             =   480
95 >      Width           =   615
96     End
97 <   Begin VB.Label Label1
98 <      Caption         =   "Packet contents"
97 >   Begin VB.Label Label3
98 >      BorderStyle     =   1  'Fixed Single
99 >      Caption         =   "0"
100        Height          =   255
101 <      Left            =   360
102 <      TabIndex        =   1
103 <      Top             =   360
104 <      Width           =   2895
101 >      Left            =   3960
102 >      TabIndex        =   3
103 >      Top             =   120
104 >      Width           =   615
105     End
106 +   Begin VB.Label Status
107 +      Alignment       =   2  'Center
108 +      Caption         =   "Status:"
109 +      Height          =   255
110 +      Left            =   120
111 +      TabIndex        =   2
112 +      Top             =   1320
113 +      Width           =   4455
114 +   End
115   End
116   Attribute VB_Name = "Form1"
117   Attribute VB_GlobalNameSpace = False
118   Attribute VB_Creatable = False
119   Attribute VB_PredeclaredId = True
120   Attribute VB_Exposed = False
121 + Private Declare Function GetPrivateProfileString Lib "kernel32" Alias "GetPrivateProfileStringA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal lpDefault As String, ByVal lpReturnedString As String, ByVal nSize As Long, ByVal lpFileName As String) As Long
122 + Private Declare Function GetPrivateProfileInt Lib "kernel32" Alias "GetPrivateProfileIntA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal nDefault As Long, ByVal lpFileName As String) As Long
123 +
124 + Dim filterManagerHostname As String
125 + Dim filterManagerTCPPort As Integer
126 +
127   Dim filterHostname As String
128 < Dim filterTCPPort As String
129 < Dim filterUDPPort As String
128 > Dim filterTCPPort As Integer
129 > Dim filterUDPPort As Integer
130 > Dim fileList As String
131 > Dim lastModified As String
132  
133 + Dim UDPUpdateTime As Integer
134 + Dim TCPUpdateTime As Integer
135 +
136   Dim protocolVersion As String
137   Dim connected As Boolean
138   Dim responseNumber As Integer
# Line 130 | Line 140 | Dim responseNumber As Integer
140  
141   Private Sub Command1_Click()
142  
143 +    ' build the contents of the XML packet.
144 +    xml = "<packet></packet>"
145 +
146      ' Use the first winsock control to send a UDP packet.
147 <    Winsock1.RemoteHost = Text3.Text
148 <    Winsock1.RemotePort = Text2.Text
149 <    Winsock1.SendData Text1.Text
147 >    UDPSock.RemoteHost = filterHostname
148 >    UDPSock.RemotePort = filterUDPPort
149 >    UDPSock.SendData xml
150 >    Status.Caption = "i-scream Winhost " & protocolVersion & " - UDP packet sent."
151  
152   End Sub
153  
140 Private Sub Command2_Click()
141    
142    ' establish a TCP connection to a machine
143    Winsock2.Close
144    Winsock2.Connect Text3.Text, Text2.Text
154  
146 End Sub
147
155   Private Sub Command3_Click()
156 <    x = MsgBox("not implemented..")
156 >    ' establish a TCP connection to a filter
157 >    TCPSock.Close
158 >    TCPSock.Connect filterHostname, filterTCPPort
159   End Sub
160  
161   Private Sub Form_Load()
162      protocolVersion = "1.1"
163 +      
164 +    Status.Caption = "Loading"
165 +    Form1.Caption = "i-scream Winhost " & protocolVersion
166 +    
167 +    ''''TEMP
168 +    filterManagerHostname = "killigrew.ukc.ac.uk"
169 +    filterManagerTCPPort = 4567
170 +    Reconfigure_Click
171 +    Exit Sub
172 +    ''' ENDTEMP
173 +    
174 +    On Error GoTo iniError
175 +    Dim buf As String * 256
176 +    Dim length As Long
177 +    length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "<no value>", buf, Len(buf), App.Path & "winhost.ini")
178 +    filterManagerHostname = Left$(buf, length)
179 +    length = GetPrivateProfileString("i-scream Winhost", "FilterManagerPort", "<no value>", buf, Len(buf), App.Path & "winhost.ini")
180 +    filterManagerTCPPort = Left$(buf, length)
181 +    
182 +    Status.Caption = "Connecting to Filter Manager"
183 +    
184 +    Exit Sub
185 +    
186 + iniError:
187 +    x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file.  Please correct these and try again.", 48, "Configuration not found")
188 +    End
189 +    
190   End Sub
191  
192 < Private Sub Winsock2_Connect()
193 <      
194 <   responseNumber = 0
192 > Private Sub Form_QueryUnload(Cancel As Integer, UnloadMode As Integer)
193 >    x = MsgBox("Are you sure you want to shut down the Winhost?  This will stop your computer sending information to the i-scream Central Monitoring System.", vbYesNo, "i-scream Winhost")
194 >    If x = 7 Then
195 >        Cancel = True
196 >    End If
197 >    SystemTray.Action = 2
198 >
199 > End Sub
200 >
201 > Private Sub Hide_Click()
202 >    Form1.Visible = False
203 >    SystemTray.Icon = Val(Form1.Icon)
204 >    SystemTray.Action = 0
205 > End Sub
206 >
207 > Private Sub Reconfigure_Click()
208 >    ' establish a TCP connection to a filtermanager
209 >    connected = False
210 >    TCPSock.Close
211 >    TCPSock.Connect filterManagerHostname, filterManagerTCPPort
212 > End Sub
213 >
214 >
215 >
216 > Private Sub SystemTray_MouseDblClk(ByVal Button As Integer)
217 >
218 >    Form1.Visible = True
219 >    SystemTray.Action = 2
220 >    Form1.SetFocus
221 >    
222 >
223 > End Sub
224 >
225 > Private Sub TCPSock_Connect()
226 >    
227 >    responseNumber = 0
228    
229 <   ' As soon as we are connected to the server, send this.
230 <   Winsock2.SendData "STARTCONFIG" & vbCrLf
229 >    ' Send something as soon as we connect to the server.
230 >    If connected = False Then
231 >        ' contact the FilterManager
232 >        TCPSock.SendData "STARTCONFIG" & vbCrLf
233 >    Else
234 >       ' Contact the Filter
235 >       TCPSock.SendData "HEARTBEAT" & vbCrLf
236 >    End If
237    
238   End Sub
239  
240 < Private Sub Winsock2_DataArrival(ByVal bytesTotal As Long)
240 > Private Sub TCPSock_DataArrival(ByVal bytesTotal As Long)
241      
242      responseNumber = responseNumber + 1
243      
244      ' Get the line from the server.
245 <    Winsock2.GetData response, vbString, bytesTotal
245 >    TCPSock.GetData response, vbString, bytesTotal
246      
247      ' Remove linefeeds and returns from the line.
248      response = Replace(response, Chr(13), "")
# Line 180 | Line 255 | Private Sub Winsock2_DataArrival(ByVal bytesTotal As L
255          Select Case responseNumber
256              Case 1:
257                  If Not response = "OK" Then GoTo configError
258 <                Winsock2.SendData "LASTMODIFIED" & vbCrLf
258 >                TCPSock.SendData "LASTMODIFIED" & vbCrLf
259              Case 2:
260                  If response = "ERROR" Then GoTo configError
261 <                Winsock2.SendData "FILELIST" & vbCrLf
261 >                lastModified = response
262 >                TCPSock.SendData "FILELIST" & vbCrLf
263              Case 3:
264                  If response = "ERROR" Then GoTo configError
265 <                Winsock2.SendData "UDPUpdateTime" & vbCrLf
265 >                fileList = response
266 >                TCPSock.SendData "UDPUpdateTime" & vbCrLf
267              Case 4:
268                  If response = "ERROR" Then GoTo configError
269 <                Winsock2.SendData "TCPUpdateTime" & vbCrLf
269 >                UDPUpdateTime = response
270 >                TCPSock.SendData "TCPUpdateTime" & vbCrLf
271              Case 5:
272                  If response = "ERROR" Then GoTo configError
273 <                Winsock2.SendData "ENDCONFIG" & vbCrLf
273 >                TCPUpdateTime = response
274 >                TCPSock.SendData "ENDCONFIG" & vbCrLf
275              Case 6:
276                  If Not response = "OK" Then GoTo configError
277 <                Winsock2.SendData "FILTER" & vbCrLf
277 >                TCPSock.SendData "FILTER" & vbCrLf
278              Case 7:
279                  'we got a filter list here.
280                  readTo = 0
# Line 209 | Line 288 | Private Sub Winsock2_DataArrival(ByVal bytesTotal As L
288                  response = Mid(response, readTo + 1, Len(response))
289                  ' get TCP Port number
290                  filterTCPPort = response
291 <                Winsock2.SendData "END" & vbCrLf
291 >                TCPSock.SendData "END" & vbCrLf
292              Case 8:
293                  If Not response = "OK" Then GoTo configError
294                  connected = True
295                  responseNumber = 0
296 <                Winsock2.Close
296 >                TCPSock.Close
297                  Text4.Text = Text4.Text & vbCrLf & "  <closed>"
298 <                x = MsgBox("got config okay")
298 >                Status.Caption = "Configuration successful"
299 >                Label3.Caption = UDPUpdateTime
300 >                Label4.Caption = TCPUpdateTime
301 >                Timer1.Interval = 1000
302          End Select
303      Else
304          ' Perform a heartbeat (1.1)
305          On Error GoTo heartbeatError
306          Select Case responseNumber
307              Case 1:
308 <                
308 >                If Not response = "OK" Then GoTo heartbeatError
309 >                TCPSock.SendData "CONFIG" & vbCrLf
310              Case 2:
311 <                
311 >                If Not response = "OK" Then GoTo heartbeatError
312 >                TCPSock.SendData fileList & vbCrLf
313              Case 3:
314 <                
314 >                If Not response = "OK" Then GoTo heartbeatError
315 >                TCPSock.SendData lastModified & vbCrLf
316              Case 4:
317 <                
317 >                If Not response = "OK" Then GoTo heartbeatError
318 >                TCPSock.SendData "ENDHEARTBEAT" & vbCrLf
319              Case 5:
320 <                
321 <            Case 6:
322 <                
237 <            Case 7:
238 <                
239 <            Case 8:
240 <                
320 >                If Not response = "OK" Then GoTo heartbeatError
321 >                TCPSock.Close
322 >                Status.Caption = "Heartbeat sent successfully."
323          End Select
324      
325      End If
# Line 246 | Line 328 | Private Sub Winsock2_DataArrival(ByVal bytesTotal As L
328      Exit Sub
329      
330   configError:
331 <    x = MsgBox("error doing configuration")
331 >    Status.Caption = "FAILED to get configuration"
332 >    Exit Sub
333   heartbeatError:
334 +    Status.Caption = "Heatbeat FAILED"
335 +    Exit Sub
336 + End Sub
337 +
338 + Private Sub Timer1_Timer()
339 +
340 +    Label3.Caption = Label3.Caption - 1
341 +    Label4.Caption = Label4.Caption - 1
342      
343 +    Status.Caption = ""
344 +    
345 +    If Label3.Caption < 1 Then
346 +        ' build the contents of the XML packet.
347 +        xml = "<packet></packet>"
348 +
349 +        ' Use the first winsock control to send a UDP packet.
350 +        UDPSock.RemoteHost = filterHostname
351 +        UDPSock.RemotePort = filterUDPPort
352 +        UDPSock.SendData xml
353 +        Status.Caption = "UDP packet sent"
354 +        Label3.Caption = UDPUpdateTime
355 +    End If
356 +    
357 +    If Label4.Caption < 1 Then
358 +        ' establish a TCP connection to a filter
359 +        TCPSock.Close
360 +        TCPSock.Connect filterHostname, filterTCPPort
361 +        Label4.Caption = TCPUpdateTime
362 +    End If
363 +
364   End Sub

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines