ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/projects/cms/source/host/winhost/nettest.frm
(Generate patch)

Comparing projects/cms/source/host/winhost/nettest.frm (file contents):
Revision 1.6 by pjm2, Fri Feb 23 10:53:30 2001 UTC vs.
Revision 1.12 by pjm2, Fri Feb 23 12:01:14 2001 UTC

# Line 1 | Line 1
1   VERSION 5.00
2   Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX"
3 + Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0"; "SysTray.ocx"
4   Begin VB.Form Form1
5 <   BorderStyle     =   3  'Fixed Dialog
6 <   Caption         =   "TCP/UDP Test program"
5 >   BorderStyle     =   4  'Fixed ToolWindow
6 >   Caption         =   "i-scream Winhost"
7     ClientHeight    =   5655
8     ClientLeft      =   45
9 <   ClientTop       =   330
10 <   ClientWidth     =   5670
9 >   ClientTop       =   285
10 >   ClientWidth     =   4710
11     LinkTopic       =   "Form1"
12     MaxButton       =   0   'False
12   MinButton       =   0   'False
13     ScaleHeight     =   5655
14 <   ScaleWidth      =   5670
14 >   ScaleWidth      =   4710
15     ShowInTaskbar   =   0   'False
16     StartUpPosition =   3  'Windows Default
17 <   Begin VB.CommandButton Command3
18 <      Caption         =   "TCP to Filter"
17 >   Begin VB.CommandButton Hide
18 >      Caption         =   "Hide Window"
19        Height          =   375
20 <      Left            =   3720
21 <      TabIndex        =   3
22 <      Top             =   2520
23 <      Width           =   1575
20 >      Left            =   3120
21 >      TabIndex        =   7
22 >      Top             =   840
23 >      Width           =   1455
24     End
25 +   Begin SysTray.SystemTray SystemTray
26 +      Left            =   2160
27 +      Top             =   1800
28 +      _ExtentX        =   847
29 +      _ExtentY        =   847
30 +      SysTrayText     =   "i-scream Winhost"
31 +      IconFile        =   0
32 +   End
33 +   Begin VB.Timer Timer1
34 +      Left            =   2760
35 +      Top             =   1800
36 +   End
37     Begin VB.TextBox Text4
38        Height          =   1575
39        Left            =   240
40        MultiLine       =   -1  'True
41        ScrollBars      =   2  'Vertical
42 <      TabIndex        =   2
42 >      TabIndex        =   1
43        Text            =   "nettest.frx":0000
44        Top             =   3000
45 <      Width           =   5055
45 >      Width           =   3975
46     End
47 <   Begin VB.CommandButton Command2
48 <      Caption         =   "TCP to FilterManager"
47 >   Begin VB.CommandButton Reconfigure
48 >      Caption         =   "Reconfigure with FilterManager"
49        Height          =   375
50 <      Left            =   3360
51 <      TabIndex        =   1
52 <      Top             =   2040
53 <      Width           =   1935
50 >      Left            =   120
51 >      TabIndex        =   0
52 >      Top             =   840
53 >      Width           =   2895
54     End
55     Begin MSWinsockLib.Winsock TCPSock
56 <      Left            =   4920
57 <      Top             =   120
56 >      Left            =   3720
57 >      Top             =   1800
58        _ExtentX        =   741
59        _ExtentY        =   741
60        _Version        =   393216
61     End
50   Begin VB.CommandButton Command1
51      Caption         =   "Send UDP"
52      Height          =   375
53      Left            =   4320
54      TabIndex        =   0
55      Top             =   1560
56      Width           =   975
57   End
62     Begin MSWinsockLib.Winsock UDPSock
63 <      Left            =   4320
64 <      Top             =   120
63 >      Left            =   3240
64 >      Top             =   1800
65        _ExtentX        =   741
66        _ExtentY        =   741
67        _Version        =   393216
68        Protocol        =   1
69     End
70 +   Begin VB.Label Label2
71 +      Alignment       =   1  'Right Justify
72 +      Caption         =   "Next heartbeat:"
73 +      Height          =   255
74 +      Left            =   2400
75 +      TabIndex        =   6
76 +      Top             =   480
77 +      Width           =   1455
78 +   End
79 +   Begin VB.Label Label1
80 +      Alignment       =   1  'Right Justify
81 +      Caption         =   "Next UDP packet:"
82 +      Height          =   255
83 +      Left            =   2400
84 +      TabIndex        =   5
85 +      Top             =   120
86 +      Width           =   1455
87 +   End
88 +   Begin VB.Label Label4
89 +      BorderStyle     =   1  'Fixed Single
90 +      Caption         =   "0"
91 +      Height          =   255
92 +      Left            =   3960
93 +      TabIndex        =   4
94 +      Top             =   480
95 +      Width           =   615
96 +   End
97 +   Begin VB.Label Label3
98 +      BorderStyle     =   1  'Fixed Single
99 +      Caption         =   "0"
100 +      Height          =   255
101 +      Left            =   3960
102 +      TabIndex        =   3
103 +      Top             =   120
104 +      Width           =   615
105 +   End
106     Begin VB.Label Status
107 +      Alignment       =   2  'Center
108        Caption         =   "Status:"
109        Height          =   255
110        Left            =   120
111 <      TabIndex        =   4
112 <      Top             =   5280
113 <      Width           =   5415
111 >      TabIndex        =   2
112 >      Top             =   1320
113 >      Width           =   4455
114     End
115   End
116   Attribute VB_Name = "Form1"
# Line 89 | Line 130 | Dim filterUDPPort As Integer
130   Dim fileList As String
131   Dim lastModified As String
132  
133 + Dim UDPUpdateTime As Integer
134 + Dim TCPUpdateTime As Integer
135 +
136   Dim protocolVersion As String
137   Dim connected As Boolean
138   Dim responseNumber As Integer
# Line 107 | Line 151 | Private Sub Command1_Click()
151  
152   End Sub
153  
110 Private Sub Command2_Click()
111    
112    ' establish a TCP connection to a filtermanager
113    TCPSock.Close
114    TCPSock.Connect filterManagerHostname, filterManagerTCPPort
154  
116 End Sub
117
155   Private Sub Command3_Click()
156      ' establish a TCP connection to a filter
157      TCPSock.Close
# Line 123 | Line 160 | End Sub
160  
161   Private Sub Form_Load()
162      protocolVersion = "1.1"
163 +      
164 +    Status.Caption = "Loading"
165 +    Form1.Caption = "i-scream Winhost " & protocolVersion
166      
127    Status.Caption = "i-scream Winhost " & protocolVersion
128    
167      ''''TEMP
168      filterManagerHostname = "killigrew.ukc.ac.uk"
169      filterManagerTCPPort = 4567
170 +    Reconfigure_Click
171      Exit Sub
172      ''' ENDTEMP
173      
# Line 140 | Line 179 | Private Sub Form_Load()
179      length = GetPrivateProfileString("i-scream Winhost", "FilterManagerPort", "<no value>", buf, Len(buf), App.Path & "winhost.ini")
180      filterManagerTCPPort = Left$(buf, length)
181      
182 <    Status.Caption = "i-scream Winhost " & protocolVersion & " connecting to Filter Manager"
182 >    Status.Caption = "Connecting to Filter Manager"
183      
184      Exit Sub
185      
# Line 150 | Line 189 | iniError:
189      
190   End Sub
191  
192 < Private Sub Label1_Click()
192 > Private Sub Form_QueryUnload(Cancel As Integer, UnloadMode As Integer)
193 >    x = MsgBox("Are you sure you want to shut down the Winhost?  This will stop your computer sending information to the i-scream Central Monitoring System.", vbYesNo, "i-scream Winhost")
194 >    If x = 7 Then
195 >        Cancel = True
196 >    End If
197 >    SystemTray.Action = 2
198  
199   End Sub
200  
201 + Private Sub Hide_Click()
202 +    Form1.Visible = False
203 +    SystemTray.Icon = Val(Form1.Icon)
204 +    SystemTray.Action = 0
205 + End Sub
206 +
207 + Private Sub Reconfigure_Click()
208 +    ' establish a TCP connection to a filtermanager
209 +    connected = False
210 +    TCPSock.Close
211 +    TCPSock.Connect filterManagerHostname, filterManagerTCPPort
212 + End Sub
213 +
214 +
215 +
216 + Private Sub SystemTray_MouseDblClk(ByVal Button As Integer)
217 +
218 +    Form1.Visible = True
219 +    SystemTray.Action = 2
220 +    Form1.SetFocus
221 +    
222 +
223 + End Sub
224 +
225   Private Sub TCPSock_Connect()
226      
227      responseNumber = 0
# Line 198 | Line 266 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
266                  TCPSock.SendData "UDPUpdateTime" & vbCrLf
267              Case 4:
268                  If response = "ERROR" Then GoTo configError
269 +                UDPUpdateTime = response
270                  TCPSock.SendData "TCPUpdateTime" & vbCrLf
271              Case 5:
272                  If response = "ERROR" Then GoTo configError
273 +                TCPUpdateTime = response
274                  TCPSock.SendData "ENDCONFIG" & vbCrLf
275              Case 6:
276                  If Not response = "OK" Then GoTo configError
# Line 225 | Line 295 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
295                  responseNumber = 0
296                  TCPSock.Close
297                  Text4.Text = Text4.Text & vbCrLf & "  <closed>"
298 <                Status.Caption = "i-scream Winhost " & protocolVersion & " - got config okay"
298 >                Status.Caption = "Configuration successful"
299 >                Label3.Caption = UDPUpdateTime
300 >                Label4.Caption = TCPUpdateTime
301 >                Timer1.Interval = 1000
302          End Select
303      Else
304          ' Perform a heartbeat (1.1)
# Line 246 | Line 319 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
319              Case 5:
320                  If Not response = "OK" Then GoTo heartbeatError
321                  TCPSock.Close
322 <                Status.Caption = "i-scream Winhost " & protocolVersion & " - heartbeat sent okay."
322 >                Status.Caption = "Heartbeat sent successfully."
323          End Select
324      
325      End If
# Line 255 | Line 328 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
328      Exit Sub
329      
330   configError:
331 <    Status.Caption = "i-scream Winhost " & protocolVersion & " - FAILED to get configuration"
331 >    Status.Caption = "FAILED to get configuration"
332 >    Exit Sub
333   heartbeatError:
334 <    Status.Caption = "i-scream Winhost " & protocolVersion & " - Heatbeat FAILED"
334 >    Status.Caption = "Heatbeat FAILED"
335 >    Exit Sub
336   End Sub
337  
338 + Private Sub Timer1_Timer()
339 +
340 +    Label3.Caption = Label3.Caption - 1
341 +    Label4.Caption = Label4.Caption - 1
342 +    
343 +    Status.Caption = ""
344 +    
345 +    If Label3.Caption < 1 Then
346 +        ' build the contents of the XML packet.
347 +        xml = "<packet></packet>"
348 +
349 +        ' Use the first winsock control to send a UDP packet.
350 +        UDPSock.RemoteHost = filterHostname
351 +        UDPSock.RemotePort = filterUDPPort
352 +        UDPSock.SendData xml
353 +        Status.Caption = "UDP packet sent"
354 +        Label3.Caption = UDPUpdateTime
355 +    End If
356 +    
357 +    If Label4.Caption < 1 Then
358 +        ' establish a TCP connection to a filter
359 +        TCPSock.Close
360 +        TCPSock.Connect filterHostname, filterTCPPort
361 +        Label4.Caption = TCPUpdateTime
362 +    End If
363 +
364 + End Sub

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines