ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/projects/cms/source/host/winhost/nettest.frm
(Generate patch)

Comparing projects/cms/source/host/winhost/nettest.frm (file contents):
Revision 1.6 by pjm2, Fri Feb 23 10:53:30 2001 UTC vs.
Revision 1.15 by pjm2, Fri Feb 23 17:08:37 2001 UTC

# Line 1 | Line 1
1   VERSION 5.00
2   Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX"
3 + Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0"; "SysTray.ocx"
4   Begin VB.Form Form1
5 <   BorderStyle     =   3  'Fixed Dialog
6 <   Caption         =   "TCP/UDP Test program"
5 >   BorderStyle     =   4  'Fixed ToolWindow
6 >   Caption         =   "i-scream Winhost"
7     ClientHeight    =   5655
8     ClientLeft      =   45
9 <   ClientTop       =   330
10 <   ClientWidth     =   5670
9 >   ClientTop       =   285
10 >   ClientWidth     =   4710
11     LinkTopic       =   "Form1"
12     MaxButton       =   0   'False
12   MinButton       =   0   'False
13     ScaleHeight     =   5655
14 <   ScaleWidth      =   5670
14 >   ScaleWidth      =   4710
15     ShowInTaskbar   =   0   'False
16     StartUpPosition =   3  'Windows Default
17 <   Begin VB.CommandButton Command3
18 <      Caption         =   "TCP to Filter"
17 >   Begin VB.CommandButton Hide
18 >      Caption         =   "Hide Window"
19        Height          =   375
20 <      Left            =   3720
21 <      TabIndex        =   3
22 <      Top             =   2520
23 <      Width           =   1575
20 >      Left            =   3120
21 >      TabIndex        =   7
22 >      Top             =   840
23 >      Width           =   1455
24     End
25 +   Begin SysTray.SystemTray SystemTray
26 +      Left            =   2160
27 +      Top             =   1800
28 +      _ExtentX        =   847
29 +      _ExtentY        =   847
30 +      SysTrayText     =   "i-scream Winhost"
31 +      IconFile        =   0
32 +   End
33 +   Begin VB.Timer Timer1
34 +      Left            =   2760
35 +      Top             =   1800
36 +   End
37     Begin VB.TextBox Text4
38        Height          =   1575
39        Left            =   240
40        MultiLine       =   -1  'True
41        ScrollBars      =   2  'Vertical
42 <      TabIndex        =   2
42 >      TabIndex        =   1
43        Text            =   "nettest.frx":0000
44        Top             =   3000
45 <      Width           =   5055
45 >      Width           =   3975
46     End
47 <   Begin VB.CommandButton Command2
48 <      Caption         =   "TCP to FilterManager"
47 >   Begin VB.CommandButton Reconfigure
48 >      Caption         =   "Reconfigure with FilterManager"
49        Height          =   375
50 <      Left            =   3360
51 <      TabIndex        =   1
52 <      Top             =   2040
53 <      Width           =   1935
50 >      Left            =   120
51 >      TabIndex        =   0
52 >      Top             =   840
53 >      Width           =   2895
54     End
55     Begin MSWinsockLib.Winsock TCPSock
56 <      Left            =   4920
57 <      Top             =   120
56 >      Left            =   3720
57 >      Top             =   1800
58        _ExtentX        =   741
59        _ExtentY        =   741
60        _Version        =   393216
61     End
50   Begin VB.CommandButton Command1
51      Caption         =   "Send UDP"
52      Height          =   375
53      Left            =   4320
54      TabIndex        =   0
55      Top             =   1560
56      Width           =   975
57   End
62     Begin MSWinsockLib.Winsock UDPSock
63 <      Left            =   4320
64 <      Top             =   120
63 >      Left            =   3240
64 >      Top             =   1800
65        _ExtentX        =   741
66        _ExtentY        =   741
67        _Version        =   393216
68        Protocol        =   1
69     End
70 +   Begin VB.Label Label2
71 +      Alignment       =   1  'Right Justify
72 +      Caption         =   "Next heartbeat:"
73 +      Height          =   255
74 +      Left            =   2400
75 +      TabIndex        =   6
76 +      Top             =   480
77 +      Width           =   1455
78 +   End
79 +   Begin VB.Label Label1
80 +      Alignment       =   1  'Right Justify
81 +      Caption         =   "Next UDP packet:"
82 +      Height          =   255
83 +      Left            =   2400
84 +      TabIndex        =   5
85 +      Top             =   120
86 +      Width           =   1455
87 +   End
88 +   Begin VB.Label Label4
89 +      BorderStyle     =   1  'Fixed Single
90 +      Caption         =   "0"
91 +      Height          =   255
92 +      Left            =   3960
93 +      TabIndex        =   4
94 +      Top             =   480
95 +      Width           =   615
96 +   End
97 +   Begin VB.Label Label3
98 +      BorderStyle     =   1  'Fixed Single
99 +      Caption         =   "0"
100 +      Height          =   255
101 +      Left            =   3960
102 +      TabIndex        =   3
103 +      Top             =   120
104 +      Width           =   615
105 +   End
106     Begin VB.Label Status
107 +      Alignment       =   2  'Center
108        Caption         =   "Status:"
109        Height          =   255
110        Left            =   120
111 <      TabIndex        =   4
112 <      Top             =   5280
113 <      Width           =   5415
111 >      TabIndex        =   2
112 >      Top             =   1320
113 >      Width           =   4455
114     End
115   End
116   Attribute VB_Name = "Form1"
# Line 77 | Line 118 | Attribute VB_GlobalNameSpace = False
118   Attribute VB_Creatable = False
119   Attribute VB_PredeclaredId = True
120   Attribute VB_Exposed = False
121 + ' For the system tray bits
122   Private Declare Function GetPrivateProfileString Lib "kernel32" Alias "GetPrivateProfileStringA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal lpDefault As String, ByVal lpReturnedString As String, ByVal nSize As Long, ByVal lpFileName As String) As Long
123   Private Declare Function GetPrivateProfileInt Lib "kernel32" Alias "GetPrivateProfileIntA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal nDefault As Long, ByVal lpFileName As String) As Long
124  
125   Dim filterManagerHostname As String
126   Dim filterManagerTCPPort As Integer
127  
128 + Dim seqNo As Long
129 + Dim machineName As String
130 +
131   Dim filterHostname As String
132   Dim filterTCPPort As Integer
133   Dim filterUDPPort As Integer
134   Dim fileList As String
135   Dim lastModified As String
136  
137 + Dim UDPUpdateTime As Integer
138 + Dim TCPUpdateTime As Integer
139 +
140   Dim protocolVersion As String
141   Dim connected As Boolean
142   Dim responseNumber As Integer
143  
96
97 Private Sub Command1_Click()
98
99    ' build the contents of the XML packet.
100    xml = "<packet></packet>"
101
102    ' Use the first winsock control to send a UDP packet.
103    UDPSock.RemoteHost = filterHostname
104    UDPSock.RemotePort = filterUDPPort
105    UDPSock.SendData xml
106    Status.Caption = "i-scream Winhost " & protocolVersion & " - UDP packet sent."
107
108 End Sub
109
110 Private Sub Command2_Click()
111    
112    ' establish a TCP connection to a filtermanager
113    TCPSock.Close
114    TCPSock.Connect filterManagerHostname, filterManagerTCPPort
115
116 End Sub
117
118 Private Sub Command3_Click()
119    ' establish a TCP connection to a filter
120    TCPSock.Close
121    TCPSock.Connect filterHostname, filterTCPPort
122 End Sub
123
144   Private Sub Form_Load()
145 +    
146      protocolVersion = "1.1"
147      
148 <    Status.Caption = "i-scream Winhost " & protocolVersion
148 >    Status.Caption = "Loading"
149 >    'Form1.Caption = "i-scream Winhost " & protocolVersion & " for " & GetVersion()
150      
151      ''''TEMP
152      filterManagerHostname = "killigrew.ukc.ac.uk"
153      filterManagerTCPPort = 4567
154 <    Exit Sub
133 <    ''' ENDTEMP
154 >    ''''' END TEMP
155      
156 +    GoTo skip
157      On Error GoTo iniError
158      Dim buf As String * 256
159      Dim length As Long
# Line 139 | Line 161 | Private Sub Form_Load()
161      filterManagerHostname = Left$(buf, length)
162      length = GetPrivateProfileString("i-scream Winhost", "FilterManagerPort", "<no value>", buf, Len(buf), App.Path & "winhost.ini")
163      filterManagerTCPPort = Left$(buf, length)
164 + skip:
165 +
166 +    Status.Caption = "Connecting to Filter Manager"
167 +    Reconfigure_Click
168      
169 <    Status.Caption = "i-scream Winhost " & protocolVersion & " connecting to Filter Manager"
169 >    Form1.Show
170 >    SystemTray.Action = 0
171      
172 +    
173      Exit Sub
174      
175   iniError:
# Line 150 | Line 178 | iniError:
178      
179   End Sub
180  
181 < Private Sub Label1_Click()
181 > Private Sub Form_QueryUnload(Cancel As Integer, UnloadMode As Integer)
182 >    x = MsgBox("Are you sure you want to shut down the Winhost?  This will stop your computer sending information to the i-scream Central Monitoring System.", vbYesNo, "i-scream Winhost")
183 >    If x = 7 Then
184 >        Cancel = True
185 >    Else
186 >        SystemTray.Action = 2
187 >    End If
188  
189   End Sub
190  
191 + Private Sub Hide_Click()
192 +    Form1.Visible = False
193 +    SystemTray.Icon = Val(Form1.Icon)
194 + End Sub
195 +
196 + Private Sub Reconfigure_Click()
197 +    ' establish a TCP connection to a filtermanager
198 +    connected = False
199 +    TCPSock.Close
200 +    TCPSock.Connect filterManagerHostname, filterManagerTCPPort
201 + End Sub
202 +
203 +
204 +
205 + Private Sub SystemTray_MouseDblClk(ByVal Button As Integer)
206 +
207 +    Form1.Visible = True
208 +    Form1.SetFocus
209 +    
210 +
211 + End Sub
212 +
213   Private Sub TCPSock_Connect()
214      
215      responseNumber = 0
# Line 198 | Line 254 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
254                  TCPSock.SendData "UDPUpdateTime" & vbCrLf
255              Case 4:
256                  If response = "ERROR" Then GoTo configError
257 +                UDPUpdateTime = response
258                  TCPSock.SendData "TCPUpdateTime" & vbCrLf
259              Case 5:
260                  If response = "ERROR" Then GoTo configError
261 +                TCPUpdateTime = response
262                  TCPSock.SendData "ENDCONFIG" & vbCrLf
263              Case 6:
264                  If Not response = "OK" Then GoTo configError
# Line 225 | Line 283 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
283                  responseNumber = 0
284                  TCPSock.Close
285                  Text4.Text = Text4.Text & vbCrLf & "  <closed>"
286 <                Status.Caption = "i-scream Winhost " & protocolVersion & " - got config okay"
286 >                Status.Caption = "Configuration successful"
287 >                Label3.Caption = UDPUpdateTime
288 >                Label4.Caption = TCPUpdateTime
289 >                Timer1.Interval = 1000
290          End Select
291      Else
292          ' Perform a heartbeat (1.1)
# Line 246 | Line 307 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
307              Case 5:
308                  If Not response = "OK" Then GoTo heartbeatError
309                  TCPSock.Close
310 <                Status.Caption = "i-scream Winhost " & protocolVersion & " - heartbeat sent okay."
310 >                Status.Caption = "Heartbeat sent successfully."
311          End Select
312      
313      End If
# Line 255 | Line 316 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
316      Exit Sub
317      
318   configError:
319 <    Status.Caption = "i-scream Winhost " & protocolVersion & " - FAILED to get configuration"
319 >    Status.Caption = "FAILED to get configuration"
320 >    Exit Sub
321   heartbeatError:
322 <    Status.Caption = "i-scream Winhost " & protocolVersion & " - Heatbeat FAILED"
322 >    Status.Caption = "Heatbeat FAILED"
323 >    Exit Sub
324   End Sub
325  
326 + Private Sub Timer1_Timer()
327 +
328 +    Label3.Caption = Label3.Caption - 1
329 +    Label4.Caption = Label4.Caption - 1
330 +    
331 +    Status.Caption = ""
332 +    
333 +    If Label3.Caption < 1 Then
334 +        
335 +        ' prepare the contents of the XML packet.
336 +        seqNo = seqNo + 1
337 +        machineName = TCPSock.LocalHostName
338 +        localIP = TCPSock.localIP
339 +        packetDate = Date2Num()
340 +        
341 +        
342 +        Dim verinfo As OSVERSIONINFO
343 +        verinfo.dwOSVersionInfoSize = Len(verinfo)
344 +        ret% = GetVersionEx(verinfo)
345 +        If ret% = 0 Then
346 +            MsgBox "Error getting Windows version Information"
347 +            End
348 +        End If
349 +          
350 +        osName = getVersion()
351 +        osVersionMajor = verinfo.dwMajorVersion
352 +        osVersionMinor = verinfo.dwMinorVersion
353 +        osBuild = verinfo.dwBuildNumber
354 +        
355 +        Dim sysinfo As SYSTEM_INFO
356 +        GetSystemInfo sysinfo
357 +        Select Case sysinfo.dwProcessorType
358 +            Case PROCESSOR_INTEL_386
359 +                processorType = "Intel 386"
360 +            Case PROCESSOR_INTEL_486
361 +                processorType = "Intel 486"
362 +            Case PROCESSOR_INTEL_PENTIUM
363 +                processorType = "Intel Pentium variant"
364 +            Case PROCESSOR_MIPS_R4000
365 +                processorType = "MIPS R4000"
366 +            Case PROCESSOR_ALPHA_21064
367 +                processorType = "DEC Alpha 21064"
368 +            Case Else
369 +                processorType = "(unknown)"
370 +        End Select
371 +        
372 +        Dim memsts As MEMORYSTATUS
373 +        Dim memory&
374 +        GlobalMemoryStatus memsts
375 +        memory& = memsts.dwTotalPhys
376 +        memTotal = memory& \ 1024
377 +        memory& = memsts.dwAvailPhys
378 +        memFree = memory& \ 1024
379 +        memory& = memsts.dwTotalVirtual
380 +        swapTotal = memory& \ 1024
381 +        memory& = memsts.dwAvailVirtual
382 +        swapFree = memory& \ 1024
383 +        
384 +        ' build the contents of the XML packet
385 +        xml = "<packet seq_no=""" & seqNo & """ machine_name=""" & machineName & """ date=""" & packetDate & """ type=""data"" ip=""" & localIP & """>" & _
386 +              "<os>" & _
387 +                "<name>" & osName & "</name>" & _
388 +                "<version>" & osVersionMajor & "</version>" & _
389 +                "<release>" & osBuild & "</release>" & _
390 +                "<platform>" & osName & "</platform>" & _
391 +                "<minor_version>" & osVersionMinor & "</minor_version>" & _
392 +                "<processor>" & processorType & "</processor>" & _
393 +              "</os>" & _
394 +              "<memory><total>" & memTotal & "</total><free>" & memFree & "</free></memory>" & _
395 +              "<swap><total>" & swapTotal & "</total><free>" & swapFree & "</free></swap>" & _
396 +              ""
397 +        Text4.Text = Text4.Text + xml
398 +
399 +        ' Use the first winsock control to send a UDP packet.
400 +        UDPSock.RemoteHost = filterHostname
401 +        UDPSock.RemotePort = filterUDPPort
402 +        UDPSock.SendData xml
403 +        Status.Caption = "UDP packet sent"
404 +        Label3.Caption = UDPUpdateTime
405 +    End If
406 +    
407 +    If Label4.Caption < 1 Then
408 +        ' establish a TCP connection to a filter
409 +        TCPSock.Close
410 +        TCPSock.Connect filterHostname, filterTCPPort
411 +        Label4.Caption = TCPUpdateTime
412 +    End If
413 +
414 + End Sub
415 +
416 + Function Date2Num() As Long
417 +    Dim x As Long
418 +    x = DateDiff("s", "1-1-1970", Now)
419 +    Date2Num = x
420 + End Function

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines