ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/projects/cms/source/host/winhost/nettest.frm
(Generate patch)

Comparing projects/cms/source/host/winhost/nettest.frm (file contents):
Revision 1.6 by pjm2, Fri Feb 23 10:53:30 2001 UTC vs.
Revision 1.19 by pjm2, Mon Feb 26 08:53:48 2001 UTC

# Line 1 | Line 1
1   VERSION 5.00
2   Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX"
3 + Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0"; "SysTray.ocx"
4   Begin VB.Form Form1
5     BorderStyle     =   3  'Fixed Dialog
6 <   Caption         =   "TCP/UDP Test program"
6 >   Caption         =   "i-scream Winhost"
7     ClientHeight    =   5655
8     ClientLeft      =   45
9     ClientTop       =   330
10 <   ClientWidth     =   5670
10 >   ClientWidth     =   4710
11     LinkTopic       =   "Form1"
12     MaxButton       =   0   'False
13     MinButton       =   0   'False
14     ScaleHeight     =   5655
15 <   ScaleWidth      =   5670
15 >   ScaleWidth      =   4710
16     ShowInTaskbar   =   0   'False
17     StartUpPosition =   3  'Windows Default
18 <   Begin VB.CommandButton Command3
19 <      Caption         =   "TCP to Filter"
18 >   Begin VB.CommandButton Hide
19 >      Caption         =   "Hide Window"
20        Height          =   375
21 <      Left            =   3720
22 <      TabIndex        =   3
23 <      Top             =   2520
24 <      Width           =   1575
21 >      Left            =   3120
22 >      TabIndex        =   7
23 >      Top             =   840
24 >      Width           =   1455
25     End
26 +   Begin SysTray.SystemTray SystemTray
27 +      Left            =   2160
28 +      Top             =   1800
29 +      _ExtentX        =   847
30 +      _ExtentY        =   847
31 +      SysTrayText     =   "i-scream Winhost"
32 +      IconFile        =   0
33 +   End
34 +   Begin VB.Timer Timer1
35 +      Left            =   2760
36 +      Top             =   1800
37 +   End
38     Begin VB.TextBox Text4
39        Height          =   1575
40        Left            =   240
41        MultiLine       =   -1  'True
42        ScrollBars      =   2  'Vertical
43 <      TabIndex        =   2
43 >      TabIndex        =   1
44        Text            =   "nettest.frx":0000
45        Top             =   3000
46 <      Width           =   5055
46 >      Width           =   3975
47     End
48 <   Begin VB.CommandButton Command2
49 <      Caption         =   "TCP to FilterManager"
48 >   Begin VB.CommandButton Reconfigure
49 >      Caption         =   "Reconfigure with FilterManager"
50        Height          =   375
51 <      Left            =   3360
52 <      TabIndex        =   1
53 <      Top             =   2040
54 <      Width           =   1935
51 >      Left            =   120
52 >      TabIndex        =   0
53 >      Top             =   840
54 >      Width           =   2895
55     End
56     Begin MSWinsockLib.Winsock TCPSock
57 <      Left            =   4920
58 <      Top             =   120
57 >      Left            =   3720
58 >      Top             =   1800
59        _ExtentX        =   741
60        _ExtentY        =   741
61        _Version        =   393216
62     End
50   Begin VB.CommandButton Command1
51      Caption         =   "Send UDP"
52      Height          =   375
53      Left            =   4320
54      TabIndex        =   0
55      Top             =   1560
56      Width           =   975
57   End
63     Begin MSWinsockLib.Winsock UDPSock
64 <      Left            =   4320
65 <      Top             =   120
64 >      Left            =   3240
65 >      Top             =   1800
66        _ExtentX        =   741
67        _ExtentY        =   741
68        _Version        =   393216
69        Protocol        =   1
70     End
71 +   Begin VB.Label Label5
72 +      Caption         =   "b e t a"
73 +      BeginProperty Font
74 +         Name            =   "MS Sans Serif"
75 +         Size            =   24
76 +         Charset         =   0
77 +         Weight          =   700
78 +         Underline       =   0   'False
79 +         Italic          =   0   'False
80 +         Strikethrough   =   0   'False
81 +      EndProperty
82 +      Height          =   615
83 +      Left            =   240
84 +      TabIndex        =   8
85 +      Top             =   120
86 +      Width           =   1815
87 +   End
88 +   Begin VB.Label Label2
89 +      Alignment       =   1  'Right Justify
90 +      Caption         =   "Next heartbeat:"
91 +      Height          =   255
92 +      Left            =   2400
93 +      TabIndex        =   6
94 +      Top             =   480
95 +      Width           =   1455
96 +   End
97 +   Begin VB.Label Label1
98 +      Alignment       =   1  'Right Justify
99 +      Caption         =   "Next UDP packet:"
100 +      Height          =   255
101 +      Left            =   2400
102 +      TabIndex        =   5
103 +      Top             =   120
104 +      Width           =   1455
105 +   End
106 +   Begin VB.Label Label4
107 +      BorderStyle     =   1  'Fixed Single
108 +      Caption         =   "0"
109 +      Height          =   255
110 +      Left            =   3960
111 +      TabIndex        =   4
112 +      Top             =   480
113 +      Width           =   615
114 +   End
115 +   Begin VB.Label Label3
116 +      BorderStyle     =   1  'Fixed Single
117 +      Caption         =   "0"
118 +      Height          =   255
119 +      Left            =   3960
120 +      TabIndex        =   3
121 +      Top             =   120
122 +      Width           =   615
123 +   End
124     Begin VB.Label Status
125 +      Alignment       =   2  'Center
126        Caption         =   "Status:"
127        Height          =   255
128 <      Left            =   120
129 <      TabIndex        =   4
130 <      Top             =   5280
131 <      Width           =   5415
128 >      Left            =   0
129 >      TabIndex        =   2
130 >      Top             =   1320
131 >      Width           =   4695
132     End
133   End
134   Attribute VB_Name = "Form1"
# Line 77 | Line 136 | Attribute VB_GlobalNameSpace = False
136   Attribute VB_Creatable = False
137   Attribute VB_PredeclaredId = True
138   Attribute VB_Exposed = False
139 + ' For the system tray bits
140   Private Declare Function GetPrivateProfileString Lib "kernel32" Alias "GetPrivateProfileStringA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal lpDefault As String, ByVal lpReturnedString As String, ByVal nSize As Long, ByVal lpFileName As String) As Long
141   Private Declare Function GetPrivateProfileInt Lib "kernel32" Alias "GetPrivateProfileIntA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal nDefault As Long, ByVal lpFileName As String) As Long
142  
143   Dim filterManagerHostname As String
144 < Dim filterManagerTCPPort As Integer
144 > Dim filterManagerTCPPort As Long
145  
146 + Dim seqNo As Long
147 + Dim machineName As String
148 +
149   Dim filterHostname As String
150   Dim filterTCPPort As Integer
151   Dim filterUDPPort As Integer
152   Dim fileList As String
153   Dim lastModified As String
154  
155 + Dim UDPUpdateTime As Integer
156 + Dim TCPUpdateTime As Integer
157 +
158   Dim protocolVersion As String
159   Dim connected As Boolean
94 Dim responseNumber As Integer
160  
161 + 'Dim CUpTime As New CUpTime
162  
163 < Private Sub Command1_Click()
163 > Dim responseNumber As Integer
164  
99    ' build the contents of the XML packet.
100    xml = "<packet></packet>"
101
102    ' Use the first winsock control to send a UDP packet.
103    UDPSock.RemoteHost = filterHostname
104    UDPSock.RemotePort = filterUDPPort
105    UDPSock.SendData xml
106    Status.Caption = "i-scream Winhost " & protocolVersion & " - UDP packet sent."
107
108 End Sub
109
110 Private Sub Command2_Click()
111    
112    ' establish a TCP connection to a filtermanager
113    TCPSock.Close
114    TCPSock.Connect filterManagerHostname, filterManagerTCPPort
115
116 End Sub
117
118 Private Sub Command3_Click()
119    ' establish a TCP connection to a filter
120    TCPSock.Close
121    TCPSock.Connect filterHostname, filterTCPPort
122 End Sub
123
165   Private Sub Form_Load()
166 +    
167      protocolVersion = "1.1"
168      
169 <    Status.Caption = "i-scream Winhost " & protocolVersion
169 >    Status.Caption = "Loading"
170 >    'Form1.Caption = "i-scream Winhost " & protocolVersion & " for " & GetVersion()
171      
172      ''''TEMP
173 <    filterManagerHostname = "killigrew.ukc.ac.uk"
174 <    filterManagerTCPPort = 4567
175 <    Exit Sub
133 <    ''' ENDTEMP
173 >    'filterManagerHostname = "killigrew.ukc.ac.uk"
174 >    'filterManagerTCPPort = 4567
175 >    ''''' END TEMP
176      
177 +    'GoTo skip
178      On Error GoTo iniError
179      Dim buf As String * 256
180      Dim length As Long
181 <    length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "<no value>", buf, Len(buf), App.Path & "winhost.ini")
181 >    length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "<no value>", buf, Len(buf), App.Path & "/winhost.ini")
182      filterManagerHostname = Left$(buf, length)
183 <    length = GetPrivateProfileString("i-scream Winhost", "FilterManagerPort", "<no value>", buf, Len(buf), App.Path & "winhost.ini")
184 <    filterManagerTCPPort = Left$(buf, length)
183 >    length = GetPrivateProfileInt("i-scream Winhost", "FilterManagerPort", 0, App.Path & "/winhost.ini")
184 >    filterManagerTCPPort = length
185 > skip:
186 >
187 >    Status.Caption = "Connecting to Filter Manager " & filterManagerHostname & ":" & filterManagerTCPPort
188 >    Reconfigure_Click
189      
190 <    Status.Caption = "i-scream Winhost " & protocolVersion & " connecting to Filter Manager"
190 >    Form1.Show
191 >    SystemTray.Action = 0
192      
193 +    
194      Exit Sub
195      
196   iniError:
197 <    x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file.  Please correct these and try again.", 48, "Configuration not found")
197 >    x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file.  Please correct these and try again.  " & Err.Description, 48, "Configuration not found")
198      End
199      
200   End Sub
201  
202 < Private Sub Label1_Click()
202 > Private Sub Form_QueryUnload(Cancel As Integer, UnloadMode As Integer)
203 >    x = MsgBox("Are you sure you want to shut down the Winhost?  This will stop your computer sending information to the i-scream Central Monitoring System.", vbYesNo, "i-scream Winhost")
204 >    If x = 7 Then
205 >        Cancel = True
206 >    Else
207 >        SystemTray.Action = 2
208 >    End If
209  
210   End Sub
211  
212 + Private Sub Hide_Click()
213 +    Form1.Visible = False
214 +    SystemTray.Icon = Val(Form1.Icon)
215 + End Sub
216 +
217 + Private Sub Reconfigure_Click()
218 +    ' establish a TCP connection to a filtermanager
219 +    connected = False
220 +    TCPSock.Close
221 +    TCPSock.Connect filterManagerHostname, filterManagerTCPPort
222 + End Sub
223 +
224 +
225 +
226 + Private Sub SystemTray_MouseDblClk(ByVal Button As Integer)
227 +
228 +    Form1.Visible = True
229 +    Form1.SetFocus
230 +    
231 +
232 + End Sub
233 +
234   Private Sub TCPSock_Connect()
235      
236      responseNumber = 0
# Line 198 | Line 275 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
275                  TCPSock.SendData "UDPUpdateTime" & vbCrLf
276              Case 4:
277                  If response = "ERROR" Then GoTo configError
278 +                UDPUpdateTime = response
279                  TCPSock.SendData "TCPUpdateTime" & vbCrLf
280              Case 5:
281                  If response = "ERROR" Then GoTo configError
282 +                TCPUpdateTime = response
283                  TCPSock.SendData "ENDCONFIG" & vbCrLf
284              Case 6:
285                  If Not response = "OK" Then GoTo configError
# Line 225 | Line 304 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
304                  responseNumber = 0
305                  TCPSock.Close
306                  Text4.Text = Text4.Text & vbCrLf & "  <closed>"
307 <                Status.Caption = "i-scream Winhost " & protocolVersion & " - got config okay"
307 >                Status.Caption = "Configuration successful"
308 >                Label3.Caption = UDPUpdateTime
309 >                Label4.Caption = TCPUpdateTime
310 >                Timer1.Interval = 1000
311          End Select
312      Else
313          ' Perform a heartbeat (1.1)
# Line 246 | Line 328 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
328              Case 5:
329                  If Not response = "OK" Then GoTo heartbeatError
330                  TCPSock.Close
331 <                Status.Caption = "i-scream Winhost " & protocolVersion & " - heartbeat sent okay."
331 >                Status.Caption = "Heartbeat sent successfully."
332          End Select
333      
334      End If
# Line 255 | Line 337 | Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo
337      Exit Sub
338      
339   configError:
340 <    Status.Caption = "i-scream Winhost " & protocolVersion & " - FAILED to get configuration"
340 >    Status.Caption = "FAILED to get configuration"
341 >    Exit Sub
342   heartbeatError:
343 <    Status.Caption = "i-scream Winhost " & protocolVersion & " - Heatbeat FAILED"
343 >    Status.Caption = "Heatbeat FAILED"
344 >    Exit Sub
345   End Sub
346  
347 + Private Sub Timer1_Timer()
348 +
349 +    Label3.Caption = Label3.Caption - 1
350 +    Label4.Caption = Label4.Caption - 1
351 +    
352 +    Status.Caption = ""
353 +    
354 +    If Label3.Caption < 1 Then
355 +        
356 +        ' prepare the contents of the XML packet.
357 +        seqNo = seqNo + 1
358 +        machineName = TCPSock.LocalHostName
359 +        LocalIP = TCPSock.LocalIP
360 +        packetDate = Date2Num()
361 +        
362 +        
363 +        Dim verinfo As OSVERSIONINFO
364 +        verinfo.dwOSVersionInfoSize = Len(verinfo)
365 +        ret% = GetVersionEx(verinfo)
366 +        If ret% = 0 Then
367 +            MsgBox "Error getting Windows version Information"
368 +            End
369 +        End If
370 +          
371 +        osName = getVersion()
372 +        osVersionMajor = verinfo.dwMajorVersion
373 +        osVersionMinor = verinfo.dwMinorVersion
374 +        osBuild = verinfo.dwBuildNumber
375 +        
376 +        Dim sysinfo As SYSTEM_INFO
377 +        GetSystemInfo sysinfo
378 +        Select Case sysinfo.dwProcessorType
379 +            Case PROCESSOR_INTEL_386
380 +                processorType = "Intel 386"
381 +            Case PROCESSOR_INTEL_486
382 +                processorType = "Intel 486"
383 +            Case PROCESSOR_INTEL_PENTIUM
384 +                processorType = "Intel Pentium variant"
385 +            Case PROCESSOR_MIPS_R4000
386 +                processorType = "MIPS R4000"
387 +            Case PROCESSOR_ALPHA_21064
388 +                processorType = "DEC Alpha 21064"
389 +            Case Else
390 +                processorType = "(unknown)"
391 +        End Select
392 +        
393 +        Dim memsts As MEMORYSTATUS
394 +        Dim memory&
395 +        GlobalMemoryStatus memsts
396 +        memory& = memsts.dwTotalPhys
397 +        memTotal = memory& \ 1024
398 +        memory& = memsts.dwAvailPhys
399 +        memFree = memory& \ 1024
400 +        memory& = memsts.dwTotalVirtual
401 +        swapTotal = memory& \ 1024
402 +        memory& = memsts.dwAvailVirtual
403 +        swapFree = memory& \ 1024
404 +        
405 +        uptime = GetTickCount \ 1000
406 +        
407 +        ' build the contents of the XML packet
408 +        xml = "<packet seq_no=""" & seqNo & """ machine_name=""" & machineName & """ date=""" & packetDate & """ type=""data"" ip=""" & LocalIP & """>" & _
409 +              "<os>" & _
410 +                "<name>" & osName & "</name>" & _
411 +                "<version>" & osVersionMajor & "</version>" & _
412 +                "<release>" & osBuild & "</release>" & _
413 +                "<platform>" & osName & "</platform>" & _
414 +                "<minor_version>" & osVersionMinor & "</minor_version>" & _
415 +                "<processor>" & processorType & "</processor>" & _
416 +                "<uptime>" & uptime & "</uptime>" & _
417 +              "</os>" & _
418 +              "<memory><total>" & memTotal & "</total><free>" & memFree & "</free></memory>" & _
419 +              "<swap><total>" & swapTotal & "</total><free>" & swapFree & "</free></swap>" & _
420 +              "</packet>"
421 +        Text4.Text = Text4.Text + xml
422 +
423 +        ' Use the first winsock control to send a UDP packet.
424 +        UDPSock.RemoteHost = filterHostname
425 +        UDPSock.RemotePort = filterUDPPort
426 +        UDPSock.SendData xml
427 +        Status.Caption = "UDP packet sent"
428 +        Label3.Caption = UDPUpdateTime
429 +    End If
430 +    
431 +    If Label4.Caption < 1 Then
432 +        ' establish a TCP connection to a filter
433 +        TCPSock.Close
434 +        TCPSock.Connect filterHostname, filterTCPPort
435 +        Label4.Caption = TCPUpdateTime
436 +    End If
437 +
438 + End Sub
439 +
440 + Function Date2Num() As Long
441 +    Dim x As Long
442 +    x = DateDiff("s", "1-1-1970", Now)
443 +    Date2Num = x
444 + End Function

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines