ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/projects/cms/source/host/winhost/nettest.frm
(Generate patch)

Comparing projects/cms/source/host/winhost/nettest.frm (file contents):
Revision 1.3 by pjm2, Fri Feb 23 10:07:55 2001 UTC vs.
Revision 1.26 by pjm2, Wed Feb 28 09:08:08 2001 UTC

# Line 1 | Line 1
1   VERSION 5.00
2   Object = "{248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0"; "MSWINSCK.OCX"
3 + Object = "{33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0"; "SysTray.ocx"
4   Begin VB.Form Form1
5     BorderStyle     =   3  'Fixed Dialog
6 <   Caption         =   "TCP/UDP Test program"
7 <   ClientHeight    =   5655
6 >   Caption         =   "i-scream Winhost"
7 >   ClientHeight    =   4905
8     ClientLeft      =   45
9     ClientTop       =   330
10 <   ClientWidth     =   5670
10 >   ClientWidth     =   4710
11 >   Icon            =   "nettest.frx":0000
12     LinkTopic       =   "Form1"
13     MaxButton       =   0   'False
14     MinButton       =   0   'False
15 <   ScaleHeight     =   5655
16 <   ScaleWidth      =   5670
15 >   ScaleHeight     =   4905
16 >   ScaleWidth      =   4710
17     ShowInTaskbar   =   0   'False
18 <   StartUpPosition =   3  'Windows Default
19 <   Begin VB.CommandButton Command3
20 <      Caption         =   "TCP to Filter"
21 <      Height          =   375
22 <      Left            =   3720
23 <      TabIndex        =   9
24 <      Top             =   2520
25 <      Width           =   1575
18 >   StartUpPosition =   2  'CenterScreen
19 >   Visible         =   0   'False
20 >   Begin VB.CommandButton Command1
21 >      Caption         =   "more"
22 >      Height          =   255
23 >      Left            =   3960
24 >      TabIndex        =   8
25 >      Top             =   840
26 >      Width           =   615
27     End
28 <   Begin VB.TextBox Text4
29 <      Height          =   2535
30 <      Left            =   240
28 >   Begin VB.TextBox Text1
29 >      Height          =   2055
30 >      Left            =   120
31 >      Locked          =   -1  'True
32        MultiLine       =   -1  'True
33        ScrollBars      =   2  'Vertical
34 <      TabIndex        =   8
35 <      Text            =   "nettest.frx":0000
36 <      Top             =   3000
33 <      Width           =   5055
34 >      TabIndex        =   7
35 >      Top             =   1200
36 >      Width           =   4455
37     End
38 <   Begin VB.CommandButton Command2
39 <      Caption         =   "TCP to FilterManager"
38 >   Begin VB.CommandButton Hide
39 >      Caption         =   "Hide Window"
40        Height          =   375
41 <      Left            =   3360
42 <      TabIndex        =   7
43 <      Top             =   2040
44 <      Width           =   1935
41 >      Left            =   3120
42 >      TabIndex        =   6
43 >      Top             =   240
44 >      Width           =   1455
45     End
46 <   Begin MSWinsockLib.Winsock Winsock2
47 <      Left            =   4920
48 <      Top             =   120
49 <      _ExtentX        =   741
50 <      _ExtentY        =   741
51 <      _Version        =   393216
46 >   Begin SysTray.SystemTray SystemTray
47 >      Left            =   2520
48 >      Top             =   4200
49 >      _ExtentX        =   847
50 >      _ExtentY        =   847
51 >      SysTrayText     =   "i-scream Winhost"
52 >      IconFile        =   0
53     End
54 <   Begin VB.TextBox Text3
55 <      Height          =   285
56 <      Left            =   1680
53 <      TabIndex        =   5
54 <      Text            =   "killigrew.ukc.ac.uk"
55 <      Top             =   1560
56 <      Width           =   2535
54 >   Begin VB.Timer Timer1
55 >      Left            =   3120
56 >      Top             =   4200
57     End
58 <   Begin VB.TextBox Text2
59 <      Height          =   285
60 <      Left            =   1680
61 <      TabIndex        =   3
62 <      Text            =   "4567"
63 <      Top             =   1920
64 <      Width           =   855
65 <   End
66 <   Begin VB.CommandButton Command1
67 <      Caption         =   "Send UDP"
58 >   Begin VB.CommandButton Reconfigure
59 >      Caption         =   "Reconfigure with FilterManager"
60        Height          =   375
61 <      Left            =   4320
70 <      TabIndex        =   2
71 <      Top             =   1560
72 <      Width           =   975
73 <   End
74 <   Begin VB.TextBox Text1
75 <      Height          =   855
76 <      Left            =   360
61 >      Left            =   840
62        TabIndex        =   0
63 <      Text            =   "<packet></packet>"
64 <      Top             =   600
80 <      Width           =   4935
63 >      Top             =   3480
64 >      Width           =   2895
65     End
66 <   Begin MSWinsockLib.Winsock Winsock1
67 <      Left            =   4320
68 <      Top             =   120
66 >   Begin MSWinsockLib.Winsock TCPSock
67 >      Left            =   4080
68 >      Top             =   4200
69        _ExtentX        =   741
70        _ExtentY        =   741
71        _Version        =   393216
72 +   End
73 +   Begin MSWinsockLib.Winsock UDPSock
74 +      Left            =   3600
75 +      Top             =   4200
76 +      _ExtentX        =   741
77 +      _ExtentY        =   741
78 +      _Version        =   393216
79        Protocol        =   1
80     End
81 <   Begin VB.Label Label3
81 >   Begin VB.Label Label2
82        Alignment       =   1  'Right Justify
83 <      Caption         =   "Destination:"
83 >      Caption         =   "Next heartbeat:"
84        Height          =   255
85 <      Left            =   360
86 <      TabIndex        =   6
87 <      Top             =   1560
88 <      Width           =   1215
85 >      Left            =   120
86 >      TabIndex        =   5
87 >      Top             =   480
88 >      Width           =   1455
89     End
90 <   Begin VB.Label Label2
90 >   Begin VB.Label Label1
91        Alignment       =   1  'Right Justify
92 <      Caption         =   "Port:"
92 >      Caption         =   "Next UDP packet:"
93        Height          =   255
94 <      Left            =   360
94 >      Left            =   120
95        TabIndex        =   4
96 <      Top             =   1920
97 <      Width           =   1215
96 >      Top             =   120
97 >      Width           =   1455
98     End
99 <   Begin VB.Label Label1
100 <      Caption         =   "Packet contents"
99 >   Begin VB.Label Label4
100 >      BorderStyle     =   1  'Fixed Single
101 >      Caption         =   "0"
102        Height          =   255
103 <      Left            =   360
103 >      Left            =   1680
104 >      TabIndex        =   3
105 >      Top             =   480
106 >      Width           =   615
107 >   End
108 >   Begin VB.Label Label3
109 >      BorderStyle     =   1  'Fixed Single
110 >      Caption         =   "0"
111 >      Height          =   255
112 >      Left            =   1680
113 >      TabIndex        =   2
114 >      Top             =   120
115 >      Width           =   615
116 >   End
117 >   Begin VB.Label Status
118 >      Alignment       =   2  'Center
119 >      Caption         =   "Status:"
120 >      Height          =   255
121 >      Left            =   0
122        TabIndex        =   1
123 <      Top             =   360
124 <      Width           =   2895
123 >      Top             =   840
124 >      Width           =   3855
125     End
126   End
127   Attribute VB_Name = "Form1"
# Line 119 | Line 129 | Attribute VB_GlobalNameSpace = False
129   Attribute VB_Creatable = False
130   Attribute VB_PredeclaredId = True
131   Attribute VB_Exposed = False
132 + ' For the system tray bits
133 + Private Declare Function GetPrivateProfileString Lib "kernel32" Alias "GetPrivateProfileStringA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal lpDefault As String, ByVal lpReturnedString As String, ByVal nSize As Long, ByVal lpFileName As String) As Long
134 + Private Declare Function GetPrivateProfileInt Lib "kernel32" Alias "GetPrivateProfileIntA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal nDefault As Long, ByVal lpFileName As String) As Long
135 +
136 + Dim filterManagerHostname As String
137 + Dim filterManagerTCPPort As Long
138 +
139 + Dim seqNo As Long
140 + Dim machineName As String
141 +
142   Dim filterHostname As String
143   Dim filterTCPPort As Integer
144   Dim filterUDPPort As Integer
145   Dim fileList As String
146   Dim lastModified As String
147  
148 + Dim UDPUpdateTime As Integer
149 + Dim TCPUpdateTime As Integer
150 +
151   Dim protocolVersion As String
152   Dim connected As Boolean
130 Dim responseNumber As Integer
153  
154 + Dim CUpTime As New CUpTime
155 + Dim wksta As New CNetWksta
156  
157 + Dim windowBig As Boolean
158 +
159 + Dim responseNumber As Integer
160 +
161   Private Sub Command1_Click()
162  
163 <    ' Use the first winsock control to send a UDP packet.
136 <    Winsock1.RemoteHost = Text3.Text
137 <    Winsock1.RemotePort = Text2.Text
138 <    Winsock1.SendData Text1.Text
163 >    ' Toggle visibility of the debug output.
164  
165 +    If windowBig Then
166 +        Form1.Height = 1500
167 +        windowBig = False
168 +    Else
169 +        Form1.Height = 4350
170 +        windowBig = True
171 +    End If
172 +
173   End Sub
174  
175 < Private Sub Command2_Click()
175 > Private Sub Form_Load()
176      
177 <    ' establish a TCP connection to a filtermanager
178 <    Winsock2.Close
179 <    Winsock2.Connect Text3.Text, Text2.Text
177 >    If App.PrevInstance Then
178 >        x = MsgBox("There is already an i-scream Winhost running on this machine.", 48, "i-scream host already running")
179 >        End
180 >    End If
181 >    
182 >    protocolVersion = "1.1"
183 >    
184 >    Status.Caption = "Loading"
185 >    Form1.Caption = "i-scream Winhost " & protocolVersion
186 >    
187 >    CUpTime.Init
188 >    
189 >    If CUpTime.isWin9x Then
190 >        x = MsgBox("Sorry, the i-scream host can only be used to monitor servers (i.e. not Win9x)", 48, "Not a server")
191 >        End
192 >    End If
193 >    
194 >    windowBig = False
195 >    
196 >    ''''TEMP
197 >    'filterManagerHostname = "killigrew.ukc.ac.uk"
198 >    'filterManagerTCPPort = 4567
199 >    ''''' END TEMP
200 >    
201 >    'GoTo skip
202 >    On Error GoTo iniError
203 >    Dim buf As String * 256
204 >    Dim length As Long
205 >    length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "<no value>", buf, Len(buf), App.Path & "/winhost.ini")
206 >    filterManagerHostname = Left$(buf, length)
207 >    length = GetPrivateProfileInt("i-scream Winhost", "FilterManagerPort", 0, App.Path & "/winhost.ini")
208 >    filterManagerTCPPort = length
209 >    If filterManagerHostname = "" Then
210 >        GoTo iniError
211 >    End If
212 >    On Error GoTo 0
213 > skip:
214  
215 +    Status.Caption = "Connecting to Filter Manager " & filterManagerHostname & ":" & filterManagerTCPPort
216 +    Reconfigure_Click
217 +    
218 +    SystemTray.Icon = Val(Form1.Icon)
219 +    SystemTray.Action = 0
220 +    
221 +    
222 +    Exit Sub
223 +    
224 + iniError:
225 +    x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file.  Please correct these and try again.  " & Err.Description, 48, "Configuration not found")
226 +    End
227 +    
228   End Sub
229  
230 < Private Sub Command3_Click()
231 <    ' establish a TCP connection to a filter
232 <    Winsock2.Close
233 <    Winsock2.Connect filterHostname, filterTCPPort
230 > Private Sub Form_QueryUnload(Cancel As Integer, UnloadMode As Integer)
231 >    x = MsgBox("Are you sure you want to shut down the Winhost?  This will stop your computer sending information to the i-scream Central Monitoring System.", vbYesNo, "i-scream Winhost")
232 >    If x = 7 Then
233 >        Cancel = True
234 >    Else
235 >        SystemTray.Action = 2
236 >    End If
237 >
238   End Sub
239  
240 < Private Sub Form_Load()
241 <    protocolVersion = "1.1"
240 > Private Sub Hide_Click()
241 >    Form1.Visible = False
242 >    SystemTray.Icon = Val(Form1.Icon)
243   End Sub
244  
245 < Private Sub Winsock2_Connect()
246 <      
247 <   responseNumber = 0
245 > Private Sub Reconfigure_Click()
246 >    ' establish a TCP connection to a filtermanager
247 >    connected = False
248 >    TCPSock.Close
249 >    TCPSock.Connect filterManagerHostname, filterManagerTCPPort
250 > End Sub
251 >
252 >
253 >
254 > Private Sub SystemTray_MouseDblClk(ByVal Button As Integer)
255 >
256 >    Form1.Visible = True
257 >    Form1.SetFocus
258 >
259 > End Sub
260 >
261 > Private Sub TCPSock_Connect()
262 >    
263 >    responseNumber = 0
264    
265      ' Send something as soon as we connect to the server.
266      If connected = False Then
267          ' contact the FilterManager
268 <        Winsock2.SendData "STARTCONFIG" & vbCrLf
268 >        TCPSock.SendData "STARTCONFIG" & vbCrLf
269      Else
270         ' Contact the Filter
271 <       Winsock2.SendData "HEARTBEAT" & vbCrLf
271 >       TCPSock.SendData "HEARTBEAT" & vbCrLf
272      End If
273    
274   End Sub
275  
276 < Private Sub Winsock2_DataArrival(ByVal bytesTotal As Long)
276 > Private Sub TCPSock_DataArrival(ByVal bytesTotal As Long)
277      
278      responseNumber = responseNumber + 1
279      
280      ' Get the line from the server.
281 <    Winsock2.GetData response, vbString, bytesTotal
281 >    TCPSock.GetData response, vbString, bytesTotal
282      
283      ' Remove linefeeds and returns from the line.
284      response = Replace(response, Chr(13), "")
285      response = Replace(response, Chr(10), "")
286 <    Text4.Text = Text4.Text & vbCrLf & response
286 >    'Text4.Text = Text4.Text & vbCrLf & response
287      
288      If connected = False Then
289          ' Perform TCP configuration (1.1)
# Line 190 | Line 291 | Private Sub Winsock2_DataArrival(ByVal bytesTotal As L
291          Select Case responseNumber
292              Case 1:
293                  If Not response = "OK" Then GoTo configError
294 <                Winsock2.SendData "LASTMODIFIED" & vbCrLf
294 >                TCPSock.SendData "LASTMODIFIED" & vbCrLf
295 >                Text1.Text = "Requesting configuration from FilterManager:- " & vbCrLf
296 >                Text1.Text = Text1.Text & response & vbCrLf
297              Case 2:
298                  If response = "ERROR" Then GoTo configError
299                  lastModified = response
300 <                Winsock2.SendData "FILELIST" & vbCrLf
300 >                Text1.Text = Text1.Text & response & vbCrLf
301 >                TCPSock.SendData "FILELIST" & vbCrLf
302 >            ''' Uncomment this for new protocol release.
303 >            'Case 2a:
304 >                'If response = "ERROR" Then GoTo configError
305 >                'fileList = response
306 >                'Text1.Text = Text1.Text & response & vbCrLf
307 >                'TCPSock.SendData "FQDN" & vbCrLf
308              Case 3:
309                  If response = "ERROR" Then GoTo configError
310                  fileList = response
311 <                Winsock2.SendData "UDPUpdateTime" & vbCrLf
311 >                Text1.Text = Text1.Text & response & vbCrLf
312 >                ' REMOVE above line, uncomment next
313 >                'machineName = response
314 >                TCPSock.SendData "UDPUpdateTime" & vbCrLf
315              Case 4:
316                  If response = "ERROR" Then GoTo configError
317 <                Winsock2.SendData "TCPUpdateTime" & vbCrLf
317 >                UDPUpdateTime = response
318 >                Text1.Text = Text1.Text & response & vbCrLf
319 >                TCPSock.SendData "TCPUpdateTime" & vbCrLf
320              Case 5:
321                  If response = "ERROR" Then GoTo configError
322 <                Winsock2.SendData "ENDCONFIG" & vbCrLf
322 >                TCPUpdateTime = response
323 >                Text1.Text = Text1.Text & response & vbCrLf
324 >                TCPSock.SendData "ENDCONFIG" & vbCrLf
325              Case 6:
326                  If Not response = "OK" Then GoTo configError
327 <                Winsock2.SendData "FILTER" & vbCrLf
327 >                Text1.Text = Text1.Text & response & vbCrLf
328 >                TCPSock.SendData "FILTER" & vbCrLf
329              Case 7:
330 +                Text1.Text = Text1.Text & response & vbCrLf
331                  'we got a filter list here.
332                  readTo = 0
333                  ' get hostname
# Line 221 | Line 340 | Private Sub Winsock2_DataArrival(ByVal bytesTotal As L
340                  response = Mid(response, readTo + 1, Len(response))
341                  ' get TCP Port number
342                  filterTCPPort = response
343 <                Winsock2.SendData "END" & vbCrLf
343 >                TCPSock.SendData "END" & vbCrLf
344              Case 8:
345                  If Not response = "OK" Then GoTo configError
346                  connected = True
347                  responseNumber = 0
348 <                Winsock2.Close
349 <                Text4.Text = Text4.Text & vbCrLf & "  <closed>"
350 <                x = MsgBox("got config okay")
348 >                TCPSock.Close
349 >                Text1.Text = Text1.Text & response & vbCrLf
350 >                'Text4.Text = Text4.Text & vbCrLf & "  <closed>"
351 >                Status.Caption = "Configuration successful"
352 >                Label3.Caption = UDPUpdateTime
353 >                Label4.Caption = TCPUpdateTime
354 >                Timer1.Interval = 1000
355          End Select
356      Else
357          ' Perform a heartbeat (1.1)
# Line 236 | Line 359 | Private Sub Winsock2_DataArrival(ByVal bytesTotal As L
359          Select Case responseNumber
360              Case 1:
361                  If Not response = "OK" Then GoTo heartbeatError
362 <                Winsock2.SendData "CONFIG" & vbCrLf
362 >                Text1.Text = "Performing heartbeat: -" & vbCrLf
363 >                Text1.Text = Text1.Text & response & vbCrLf
364 >                TCPSock.SendData "CONFIG" & vbCrLf
365              Case 2:
366                  If Not response = "OK" Then GoTo heartbeatError
367 <                Winsock2.SendData fileList & vbCrLf
367 >                Text1.Text = Text1.Text & response & vbCrLf
368 >                TCPSock.SendData fileList & vbCrLf
369              Case 3:
370                  If Not response = "OK" Then GoTo heartbeatError
371 <                Winsock2.SendData lastModified & vbCrLf
371 >                Text1.Text = Text1.Text & response & vbCrLf
372 >                TCPSock.SendData lastModified & vbCrLf
373              Case 4:
374                  If Not response = "OK" Then GoTo heartbeatError
375 <                Winsock2.SendData "ENDHEARTBEAT" & vbCrLf
375 >                Text1.Text = Text1.Text & response & vbCrLf
376 >                TCPSock.SendData "ENDHEARTBEAT" & vbCrLf
377              Case 5:
378                  If Not response = "OK" Then GoTo heartbeatError
379 <                Winsock2.Close
380 <                x = MsgBox("heartbeat sent okay.")
379 >                Text1.Text = Text1.Text & response & vbCrLf
380 >                TCPSock.Close
381 >                Status.Caption = "Heartbeat sent successfully."
382          End Select
383      
384      End If
# Line 258 | Line 387 | Private Sub Winsock2_DataArrival(ByVal bytesTotal As L
387      Exit Sub
388      
389   configError:
390 <    x = MsgBox("error doing configuration")
390 >    Status.Caption = "FAILED to get configuration"
391 >    Exit Sub
392   heartbeatError:
393 +    Status.Caption = "Heatbeat FAILED"
394 +    Exit Sub
395 + End Sub
396 +
397 + Private Sub Timer1_Timer()
398 +
399 +    Label3.Caption = Label3.Caption - 1
400 +    Label4.Caption = Label4.Caption - 1
401      
402 +    Status.Caption = ""
403 +    
404 +    If Label3.Caption < 1 Then
405 +        
406 +        ' prepare the contents of the XML packet.
407 +        seqNo = seqNo + 1
408 +        
409 +        ' Comment this line in the next protocol
410 +        machineName = TCPSock.LocalHostName
411 +        
412 +        LocalIP = TCPSock.LocalIP
413 +        packetDate = Date2Num()
414 +        
415 +        
416 +        Dim verinfo As OSVERSIONINFO
417 +        verinfo.dwOSVersionInfoSize = Len(verinfo)
418 +        ret% = GetVersionEx(verinfo)
419 +        If ret% = 0 Then
420 +            MsgBox "Error getting Windows version Information"
421 +            End
422 +        End If
423 +          
424 +        osName = GetVersion()
425 +        osVersionMajor = verinfo.dwMajorVersion
426 +        osVersionMinor = verinfo.dwMinorVersion
427 +        osBuild = verinfo.dwBuildNumber
428 +        
429 +        Dim sysinfo As SYSTEM_INFO
430 +        GetSystemInfo sysinfo
431 +        Select Case sysinfo.dwProcessorType
432 +            Case PROCESSOR_INTEL_386
433 +                processorType = "Intel 386"
434 +            Case PROCESSOR_INTEL_486
435 +                processorType = "Intel 486"
436 +            Case PROCESSOR_INTEL_PENTIUM
437 +                processorType = "Intel Pentium variant"
438 +            Case PROCESSOR_MIPS_R4000
439 +                processorType = "MIPS R4000"
440 +            Case PROCESSOR_ALPHA_21064
441 +                processorType = "DEC Alpha 21064"
442 +            Case Else
443 +                processorType = "(unknown)"
444 +        End Select
445 +        
446 +        Dim memsts As MEMORYSTATUS
447 +        Dim memory&
448 +        GlobalMemoryStatus memsts
449 +        memory& = memsts.dwTotalPhys
450 +        memTotal = memory& \ 1024
451 +        memory& = memsts.dwAvailPhys
452 +        memFree = memory& \ 1024
453 +        memory& = memsts.dwTotalVirtual
454 +        swapTotal = memory& \ 1024
455 +        memory& = memsts.dwAvailVirtual
456 +        swapFree = memory& \ 1024
457 +        
458 +        uptime = CUpTime.MilliSecs \ 1000
459 +        
460 +        CUpTime.Capture
461 +        cpu_time = CUpTime.CPUTime
462 +        percent_idle = CUpTime.PercentIdle
463 +        
464 +        ' build the contents of the XML packet
465 +        xml = "<packet seq_no=""" & seqNo & """ machine_name=""" & machineName & """ date=""" & packetDate & """ type=""data"" ip=""" & LocalIP & """>" & _
466 +              "<os>" & _
467 +                "<name>" & osName & "</name>" & _
468 +                "<version>" & osVersionMajor & "</version>" & _
469 +                "<release>" & osBuild & "</release>" & _
470 +                "<platform>" & osName & "</platform>" & _
471 +                "<minor_version>" & osVersionMinor & "</minor_version>" & _
472 +                "<processor>" & processorType & "</processor>" & _
473 +                "<uptime>" & uptime & "</uptime>" & _
474 +              "</os>" & _
475 +              "<cpu><idle>" & percent_idle & "</idle><user>" & cpu_time & "</user></cpu>" & _
476 +              "<memory><total>" & memTotal & "</total><free>" & memFree & "</free></memory>" & _
477 +              "<swap><total>" & swapTotal & "</total><free>" & swapFree & "</free></swap>" & _
478 +              "</packet>"
479 +        Text1.Text = "Last packet contained: -" & vbCrLf & xml
480 +
481 +        ' Use the first winsock control to send a UDP packet.
482 +        UDPSock.RemoteHost = filterHostname
483 +        UDPSock.RemotePort = filterUDPPort
484 +        UDPSock.SendData xml
485 +        Status.Caption = "UDP packet sent"
486 +        Label3.Caption = UDPUpdateTime
487 +    End If
488 +    
489 +    If Label4.Caption < 1 Then
490 +        ' establish a TCP connection to a filter
491 +        TCPSock.Close
492 +        TCPSock.Connect filterHostname, filterTCPPort
493 +        Label4.Caption = TCPUpdateTime
494 +    End If
495 +
496   End Sub
497 +
498 + Function Date2Num() As Long
499 +    Dim x As Long
500 +    x = DateDiff("s", "1-1-1970", Now)
501 +    Date2Num = x
502 + End Function

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines