--- projects/cms/source/host/winhost/nettest.frm 2001/02/23 17:37:04 1.17 +++ projects/cms/source/host/winhost/nettest.frm 2001/02/26 09:12:51 1.20 @@ -8,6 +8,7 @@ Begin VB.Form Form1 ClientLeft = 45 ClientTop = 330 ClientWidth = 4710 + Icon = "nettest.frx":0000 LinkTopic = "Form1" MaxButton = 0 'False MinButton = 0 'False @@ -41,7 +42,7 @@ Begin VB.Form Form1 MultiLine = -1 'True ScrollBars = 2 'Vertical TabIndex = 1 - Text = "nettest.frx":0000 + Text = "nettest.frx":0742 Top = 3000 Width = 3975 End @@ -125,10 +126,10 @@ Begin VB.Form Form1 Alignment = 2 'Center Caption = "Status:" Height = 255 - Left = 120 + Left = 0 TabIndex = 2 Top = 1320 - Width = 4455 + Width = 4695 End End Attribute VB_Name = "Form1" @@ -141,7 +142,7 @@ Private Declare Function GetPrivateProfileString Lib " Private Declare Function GetPrivateProfileInt Lib "kernel32" Alias "GetPrivateProfileIntA" (ByVal lpApplicationName As String, ByVal lpKeyName As String, ByVal nDefault As Long, ByVal lpFileName As String) As Long Dim filterManagerHostname As String -Dim filterManagerTCPPort As Integer +Dim filterManagerTCPPort As Long Dim seqNo As Long Dim machineName As String @@ -170,31 +171,32 @@ Private Sub Form_Load() 'Form1.Caption = "i-scream Winhost " & protocolVersion & " for " & GetVersion() ''''TEMP - filterManagerHostname = "killigrew.ukc.ac.uk" - filterManagerTCPPort = 4567 + 'filterManagerHostname = "killigrew.ukc.ac.uk" + 'filterManagerTCPPort = 4567 ''''' END TEMP - GoTo skip + 'GoTo skip On Error GoTo iniError Dim buf As String * 256 Dim length As Long - length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "", buf, Len(buf), App.Path & "winhost.ini") + length = GetPrivateProfileString("i-scream Winhost", "FilterManager", "", buf, Len(buf), App.Path & "/winhost.ini") filterManagerHostname = Left$(buf, length) - length = GetPrivateProfileString("i-scream Winhost", "FilterManagerPort", "", buf, Len(buf), App.Path & "winhost.ini") - filterManagerTCPPort = Left$(buf, length) + length = GetPrivateProfileInt("i-scream Winhost", "FilterManagerPort", 0, App.Path & "/winhost.ini") + filterManagerTCPPort = length + On Error GoTo 0 skip: - Status.Caption = "Connecting to Filter Manager" + Status.Caption = "Connecting to Filter Manager " & filterManagerHostname & ":" & filterManagerTCPPort Reconfigure_Click - Form1.Show + SystemTray.Icon = Val(Form1.Icon) SystemTray.Action = 0 Exit Sub iniError: - x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file. Please correct these and try again.", 48, "Configuration not found") + x = MsgBox("The i-scream Winhost could not read the correct settings from the winhost.ini file. Please correct these and try again. " & Err.Description, 48, "Configuration not found") End End Sub @@ -402,6 +404,8 @@ Private Sub Timer1_Timer() memory& = memsts.dwAvailVirtual swapFree = memory& \ 1024 + uptime = GetTickCount \ 1000 + ' build the contents of the XML packet xml = "" & _ "" & _ @@ -411,6 +415,7 @@ Private Sub Timer1_Timer() "" & osName & "" & _ "" & osVersionMinor & "" & _ "" & processorType & "" & _ + "" & uptime & "" & _ "" & _ "" & memTotal & "" & memFree & "" & _ "" & swapTotal & "" & swapFree & "" & _