--- projects/cms/source/host/winhost/nettest.frm 2001/02/28 12:04:17 1.31 +++ projects/cms/source/host/winhost/nettest.frm 2001/03/14 11:03:45 1.34 @@ -139,17 +139,22 @@ Dim filterManagerTCPPort As Long Dim seqNo As Long Dim machineName As String +Dim secondsRunning As Long + Dim filterHostname As String Dim filterTCPPort As Integer Dim filterUDPPort As Integer Dim fileList As String Dim lastModified As String +Dim fourtySevenDays As Integer + Dim UDPUpdateTime As Integer Dim TCPUpdateTime As Integer Dim protocolVersion As String Dim connected As Boolean +Dim heartBeating As Boolean Dim CUpTime As New CUpTime Dim wksta As New CNetWksta @@ -179,6 +184,9 @@ Private Sub Form_Load() End End If + ' Assume the host is run within the first 47 days of the machine starting. + fourtySevenDays = 0 + protocolVersion = "1.1" Status.Caption = "Loading" @@ -242,15 +250,16 @@ Private Sub Hide_Click() SystemTray.Icon = Val(Form1.Icon) End Sub -Private Sub Image1_Click() -End Sub - Private Sub Reconfigure_Click() ' establish a TCP connection to a filtermanager - connected = False - TCPSock.Close - TCPSock.Connect filterManagerHostname, filterManagerTCPPort + If Not heartBeating Then + connected = False + TCPSock.Close + TCPSock.Connect filterManagerHostname, filterManagerTCPPort + Else + Status.Caption = "Cannot reconfigure while heartbeating" + End If End Sub @@ -356,6 +365,7 @@ Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo End Select Else ' Perform a heartbeat (1.1) + heartBeating = True On Error GoTo heartbeatError Select Case responseNumber Case 1: @@ -372,7 +382,10 @@ Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo Text1.Text = Text1.Text & response & vbCrLf TCPSock.SendData lastModified & vbCrLf Case 4: - If Not response = "OK" Then GoTo heartbeatError + If Not response = "OK" Then + heartBeating = False + Reconfigure_Click + End If Text1.Text = Text1.Text & response & vbCrLf TCPSock.SendData "ENDHEARTBEAT" & vbCrLf Case 5: @@ -388,9 +401,11 @@ Private Sub TCPSock_DataArrival(ByVal bytesTotal As Lo Exit Sub configError: - Status.Caption = "FAILED to get configuration" + heartBeating = False + Status.Caption = "FAILED to get configuration from the server" Exit Sub heartbeatError: + heartBeating = False Status.Caption = "Heatbeat FAILED" Exit Sub End Sub @@ -455,11 +470,17 @@ Private Sub Timer1_Timer() memory& = memsts.dwAvailVirtual swapFree = memory& \ 1048576 - uptime = CUpTime.MilliSecs \ 1000 - CUpTime.Capture cpu_time = CUpTime.CPUTime percent_idle = CUpTime.PercentIdle + + '' Doesn't work after 47 days :-/ + 'uptime = GetTickCount \ 1000 + + 'secondsRunning = secondsRunning + UDPUpdateTime + 'uptime = secondsRunning + + uptime = CUpTime.MilliSecs / 1000# userCount = wksta.LoggedOnUsers