Committed: Thu Mar 1 09:30:55 2001 UTC (23 years, 8 months ago) by pjm2
Branch: MAIN
Changes since 1.8: +5 -4 lines
Log Message:
Fixed uptime > 47 problem by sending uptime as the number of seconds the
program has been running rather than milliseconds_running / 1000.  This is
not ideal, but it should be okay if the host is started automatically as
each machine starts.

File Contents

# Content
1 Type=Exe
2 Form=..\..\..\experimental\host\vb_net_test\nettest.frm
3 Reference=*\G{00020430-0000-0000-C000-000000000046}#2.0#0#C:\WINNT\System32\stdole2.tlb#OLE Automation
4 Object={248DD890-BB45-11CF-9ABC-0080C7E7B78D}#1.0#0; MSWINSCK.OCX
5 Object={33155A3D-0CE0-11D1-A6B4-444553540000}#1.0#0; SysTray.ocx
6 Module=Imports; ..\..\..\experimental\host\vb_net_test\Imports.bas
7 Class=CUpTime; ..\..\..\experimental\host\vb_net_test\CUpTime.cls
8 Class=CNetWksta; ..\..\..\experimental\host\vb_net_test\CNetWksta.cls
9 IconForm="Form1"
10 Startup="Form1"
11 ExeName32="winhost.exe"
12 Path32="..\..\..\experimental\host\vb_net_test"
13 Command32=""
14 Name="Project1"
15 HelpContextID="0"
16 CompatibleMode="0"
17 MajorVer=1
18 MinorVer=0
19 RevisionVer=0
20 AutoIncrementVer=0
21 ServerSupportFiles=0
22 VersionCompanyName="University of Kent at Canterbury"
23 CompilationType=0
24 OptimizationType=0
25 FavorPentiumPro(tm)=0
26 CodeViewDebugInfo=0
27 NoAliasing=0
28 BoundsCheck=0
29 OverflowCheck=0
30 FlPointCheck=0
31 FDIVCheck=0
32 UnroundedFP=0
33 StartMode=0
34 Unattended=0
35 Retained=0
36 ThreadPerObject=0
37 MaxNumberOfThreads=1