# Line 18 | Line 18 | group.rocks=Host.agate.ukc.ac.uk;Host.arkose.ukc.ac.uk
18              Host.chert.ukc.ac.uk;Host.granite.ukc.ac.uk;Host.jade.ukc.ac.uk;Host.jasper.ukc.ac.uk;\
19              Host.magnetite.ukc.ac.uk;Host.obsidian.ukc.ac.uk;Host.pumice.ukc.ac.uk;\
20              Host.pyrite.ukc.ac.uk;Host.slate.ukc.ac.uk;Host.topaz.ukc.ac.uk;
21 + group.compsoc=Host.compsoc1.ukc.ac.uk
22  
23   config.computing=computing.conf
24   config.rocks=rocks.conf
25 + config.compsoc1=rocks.conf
26  
27   # for library machines
28   group.library=Host.129.12.58.*;
# Line 119 | Line 121 | Host.serviceChecksPackage=uk.org.iscream.filter.plugin
121   #### Monitor Configuration
122   ############################################################
123  
124 < # the monitors to run
124 > ## The monitors to run
125   Monitor.PluginsPackage=uk.org.iscream.client.monitors
126 < Monitor.Plugins=CPU;Disk;Memory;Swap;Services;Heartbeat;WebFeeder;
126 > Monitor.Plugins=CPU;Load;Process;Disk;Memory;Swap;Services;Heartbeat;Queue;WebFeeder;
127  
128 + ## Default alert timeouts
129 + # these can be override on a per-monitor basis
130 + # timings of the alerts (in seconds)
131 + Monitor.alertTimeout.NOTICE=60
132 + Monitor.alertTimeout.WARNING=900
133 + Monitor.alertTimeout.CAUTION=1800
134 + Monitor.alertTimeout.CRITICAL=3600
135  
136 < ## CPU monitor configuration
128 < # threshold values
136 > ## Threshold values
137   #
138   # note: if the UPPER threshold is broken,
139   # the alertTimeout values are halved.
140   # This is to escalate the alert quicker.
141 + #
142 +
143 + # CPU monitor threshold values
144   Monitor.CPU.threshold.LOWER=90
145   Monitor.CPU.threshold.UPPER=99
146  
136 # timings of the alerts (in seconds)
137 Monitor.CPU.alertTimeout.NOTICE=60
138 Monitor.CPU.alertTimeout.WARNING=900
139 Monitor.CPU.alertTimeout.CAUTION=1800
140 Monitor.CPU.alertTimeout.CRITICAL=3600
147  
148 + # Load monitor threshold values
149 + Monitor.Load.threshold.LOWER=10.0
150 + Monitor.Load.threshold.UPPER=20.0
151  
152 < ## Memory monitor configuration
153 < # threshold values
154 < #
155 < # note: if the UPPER threshold is broken,
156 < # the alertTimeout values are halved.
157 < # This is to escalate the alert quicker.
152 >
153 > # Process Count threshold values
154 > Monitor.Process.threshold.LOWER=1000
155 > Monitor.Process.threshold.UPPER=1500
156 >
157 >
158 > # Memory monitor threshold values
159   Monitor.Memory.threshold.LOWER=80
160   Monitor.Memory.threshold.UPPER=90
161  
152 # timings of the alerts (in seconds)
153 Monitor.Memory.alertTimeout.NOTICE=60
154 Monitor.Memory.alertTimeout.WARNING=900
155 Monitor.Memory.alertTimeout.CAUTION=1800
156 Monitor.Memory.alertTimeout.CRITICAL=3600
162  
163 <
159 < ## Swap monitor configuration
160 < # threshold values
161 < #
162 < # note: if the UPPER threshold is broken,
163 < # the alertTimeout values are halved.
164 < # This is to escalate the alert quicker.
163 > # Swap monitor threshold values
164   Monitor.Swap.threshold.LOWER=80
165   Monitor.Swap.threshold.UPPER=90
166  
168 # timings of the alerts (in seconds)
169 Monitor.Swap.alertTimeout.NOTICE=60
170 Monitor.Swap.alertTimeout.WARNING=900
171 Monitor.Swap.alertTimeout.CAUTION=1800
172 Monitor.Swap.alertTimeout.CRITICAL=3600
167  
168 + # Disk monitor threshold values
169 + Monitor.Disk.threshold.LOWER=90
170 + Monitor.Disk.threshold.UPPER=95
171 + # Thresholds given are PERCENTAGE or VALUE
172 + # where PERCENTAGE is a percentage of disk in use
173 + # and VALUE is an absolute value of space free
174 + Monitor.Disk.thresholdMeasure=PERCENTAGE
175  
175 ## Disk monitor configuration
176 # threshold values
177 #
178 # note: if the UPPER threshold is broken,
179 # the alertTimeout values are halved.
180 # This is to escalate the alert quicker.
181 Monitor.Disk.threshold.LOWER=80
182 Monitor.Disk.threshold.UPPER=90
176  
177 < # timings of the alerts (in seconds)
178 < Monitor.Disk.alertTimeout.NOTICE=60
179 < Monitor.Disk.alertTimeout.WARNING=900
180 < Monitor.Disk.alertTimeout.CAUTION=1800
181 < Monitor.Disk.alertTimeout.CRITICAL=3600
177 > # Disk monitor threshold values
178 > Monitor.Queue.threshold.LOWER=90
179 > Monitor.Queue.threshold.UPPER=95
180 > # Thresholds given are PERCENTAGE or VALUE
181 > # where PERCENTAGE is a percentage of disk in use
182 > # and VALUE is an absolute value of space free
183 > Monitor.Queue.thresholdMeasure=PERCENTAGE
184  
185  
186 < ## Services monitor configuration
192 < # threshold values
186 > # Services monitor threshold values
187   #
188   # THE SERVICES MONITOR USES A HACK
189   # WHEREBY IT USES THE SERVICE STATUS
190   # AS THE THRESHOLD LEVEL.  THIS SHOULD
191   # BE LOOKED AT!
192   #
193 < # note: if the UPPER threshold is broken,
194 < # the alertTimeout values are halved.
201 < # This is to escalate the alert quicker.
202 < #Monitor.Services.threshold.LOWER=120
203 < #Monitor.Services.threshold.LOWER=300
204 <
205 < # timings of the alerts (in seconds)
206 < Monitor.Services.alertTimeout.NOTICE=60
207 < Monitor.Services.alertTimeout.WARNING=900
208 < Monitor.Services.alertTimeout.CAUTION=1800
209 < Monitor.Services.alertTimeout.CRITICAL=3600
210 <
211 < # Make sure we shut up eventually
193 > # how many times we should be at the highest level before
194 > # we go to a FINAL alert
195   Monitor.Services.reachFINALcount=5
196  
197  
198 < ## Heartbeat monitor configuration
216 < # threshold values
217 < #
218 < # note: if the UPPER threshold is broken,
219 < # the alertTimeout values are halved.
220 < # This is to escalate the alert quicker.
221 < Monitor.Heartbeat.checkPeriod=50
198 > # Heartbeat threshold values
199   # these are values in seconds from when the heartbeat
200   # was *expected* to arrive (ie. last + hearbeat period)
201 < Monitor.Heartbeat.threshold.LOWER=120
201 > Monitor.Heartbeat.threshold.LOWER=180
202   Monitor.Heartbeat.threshold.UPPER=300
203 + # this is how often we will run a "check" of heartbeats
204 + Monitor.Heartbeat.checkPeriod=50
205 + # how many times we should be at the highest level before
206 + # we go to a FINAL alert
207 + Monitor.Heartbeat.reachFINALcount=5
208  
227 # timings of the alerts (in seconds)
228 Monitor.Heartbeat.alertTimeout.NOTICE=60
229 Monitor.Heartbeat.alertTimeout.WARNING=900
230 Monitor.Heartbeat.alertTimeout.CAUTION=1800
231 Monitor.Heartbeat.alertTimeout.CRITICAL=3600
209  
233 # this means it will reach a FINAL level,
234 # and thus the host will be removed from the monitor list,
235 # if the highest level alert is reached and occours this
236 # number of times.
237 #
238 # int this setup, that means 5 CRITICAL alerts would occour
239 # on a Heartbeat before reaching FINAL.
240 # If this value is wrong or not present, FINAL is never reached
241 #
242 Monitor.Heartbeat.reachFINALcount=5
210  
211   ############################################################
212   #### Alerter Configuration
# Line 261 | Line 228 | Monitor.Heartbeat.reachFINALcount=5
228   Alerter.PluginsPackage=uk.org.iscream.client.alerters
229   Alerter.Plugins=EMail;IRC;WebFeeder;
230  
231 +
232   # EMail alerter configuration
233   Alerter.EMail.level = WARNING
234   Alerter.EMail.destList = dev@i-scream.org.uk
# Line 293 | Line 261 | Alerter.IRC.versionCommand = version
261   Alerter.IRC.helpCommand = help
262   Alerter.IRC.rejectMessage = sorry, I don't understand your request
263  
264 +
265 +
266   ############################################################
267   #### WebFeeder Configuration
268   ############################################################
# Line 302 | Line 272 | Alerter.IRC.rejectMessage = sorry, I don't understand
272   WebFeeder.latestActive = true
273   WebFeeder.alertActive = true
274  
275 + # Only pass on alerts past this level
276 + WebFeeder.alertLevel = OK
277 +
278   # Check period in seconds (for cleaning stale/old alerts)
279 < WebFeeder.checkPeriod = 900
279 > WebFeeder.checkPeriod = 120
280  
281   # Delete alerts older than this, in seconds.
282   # Files are only check every WebFeeder.checkPeriod seconds.
283 < WebFeeder.alertDeleteOlderThan = 1800
283 > WebFeeder.alertDeleteOlderThan = 300
284  
285   # Root Path
286   WebFeeder.rootPath = /usr/local/proj/co600_10/webroot
# Line 320 | Line 293 | WebFeeder.latestFileName = latest_data
293   WebFeeder.alertSubDir = alert
294   WebFeeder.alertFileName = alert_data
295  
323 ############################################################
296  
297 + ############################################################

Diff Legend