ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/projects/cms/source/server/build/etc/system.conf
(Generate patch)

Comparing projects/cms/source/server/build/etc/system.conf (file contents):
Revision 1.19 by tdb, Sun Mar 4 05:35:55 2001 UTC vs.
Revision 1.42 by tdb, Mon Mar 19 20:57:41 2001 UTC

# Line 14 | Line 14
14  
15   # for computing machines
16   group.computing=Host.129.12.4.*;
17 + group.rocks=Host.agate.ukc.ac.uk;Host.arkose.ukc.ac.uk;Host.basalt.ukc.ac.uk;Host.chalk.ukc.ac.uk;\
18 +            Host.chert.ukc.ac.uk;Host.granite.ukc.ac.uk;Host.jade.ukc.ac.uk;Host.jasper.ukc.ac.uk;\
19 +            Host.magnetite.ukc.ac.uk;Host.obsidian.ukc.ac.uk;Host.pumice.ukc.ac.uk;\
20 +            Host.pyrite.ukc.ac.uk;Host.slate.ukc.ac.uk;Host.topaz.ukc.ac.uk;
21 + group.compsoc=Host.compsoc1.ukc.ac.uk
22 +
23   config.computing=computing.conf
24 + config.rocks=rocks.conf
25 + config.compsoc1=rocks.conf
26  
27   # for library machines
28   group.library=Host.129.12.58.*;
# Line 37 | Line 45 | ConfigurationProxy.updateTime=60
45  
46   # The time interval at which the Queue's should be monitored
47   Queue.MonitorInterval=15
48 + # The upper limit for a Queue
49 + Queue.SizeLimit=1000
50 + # The removal algorithm
51 + Queue.RemoveAlgorithm=FIRST
52  
53  
42
54   ############################################################
55   #### FilterManager configuration
56   ############################################################
# Line 58 | Line 69 | Filter.UDPListenPort=4589
69   Filter.TCPListenPort=4589
70  
71   # Plugin Information
72 < Filter.PluginsPackage=uk.ac.ukc.iscream.filter.plugins
72 > Filter.PluginsPackage=uk.org.iscream.filter.plugins
73   Filter.Plugins=TypeChecker;EnforceEssentialData
74  
75   # The name for the root filter
# Line 94 | Line 105 | ClientInterface.listenPort=4510
105   ############################################################
106  
107   # The default filter for a new host
108 < Host.filter=filter1
108 > Host.filter=computingFilter;
109  
110   # The default update times for a new host
111   Host.UDPUpdateTime=10
# Line 102 | Line 113 | Host.TCPUpdateTime=60
113   Host.AveragerUpdateTime=5
114  
115   # The services checks to run on a host
116 < Host.serviceChecksPackage=uk.ac.ukc.iscream.filter.plugins
106 < Host.serviceChecks=HTTP;SMTP
116 > Host.serviceChecksPackage=uk.org.iscream.filter.plugins
117  
118  
119  
# Line 112 | Line 122 | Host.serviceChecks=HTTP;SMTP
122   ############################################################
123  
124   # the monitors to run
125 < Monitor.PluginsPackage=uk.ac.ukc.iscream.client.monitors
126 < Monitor.Plugins=CPU;
125 > Monitor.PluginsPackage=uk.org.iscream.client.monitors
126 > Monitor.Plugins=CPU;Disk;Memory;Swap;Services;Heartbeat;WebFeeder;
127 > #Monitor.Plugins=CPU;WebFeeder;
128 > #Monitor.Plugins=
129  
130 < # CPU monitor configuration
130 >
131 > ## CPU monitor configuration
132   # threshold values
133   #
134   # note: if the UPPER threshold is broken,
# Line 131 | Line 144 | Monitor.CPU.alertTimeout.CAUTION=1800
144   Monitor.CPU.alertTimeout.CRITICAL=3600
145  
146  
147 + ## Memory monitor configuration
148 + # threshold values
149 + #
150 + # note: if the UPPER threshold is broken,
151 + # the alertTimeout values are halved.
152 + # This is to escalate the alert quicker.
153 + Monitor.Memory.threshold.LOWER=80
154 + Monitor.Memory.threshold.UPPER=90
155  
156 + # timings of the alerts (in seconds)
157 + Monitor.Memory.alertTimeout.NOTICE=60
158 + Monitor.Memory.alertTimeout.WARNING=900
159 + Monitor.Memory.alertTimeout.CAUTION=1800
160 + Monitor.Memory.alertTimeout.CRITICAL=3600
161 +
162 +
163 + ## Swap monitor configuration
164 + # threshold values
165 + #
166 + # note: if the UPPER threshold is broken,
167 + # the alertTimeout values are halved.
168 + # This is to escalate the alert quicker.
169 + Monitor.Swap.threshold.LOWER=80
170 + Monitor.Swap.threshold.UPPER=90
171 +
172 + # timings of the alerts (in seconds)
173 + Monitor.Swap.alertTimeout.NOTICE=60
174 + Monitor.Swap.alertTimeout.WARNING=900
175 + Monitor.Swap.alertTimeout.CAUTION=1800
176 + Monitor.Swap.alertTimeout.CRITICAL=3600
177 +
178 +
179 + ## Disk monitor configuration
180 + # threshold values
181 + #
182 + # note: if the UPPER threshold is broken,
183 + # the alertTimeout values are halved.
184 + # This is to escalate the alert quicker.
185 + Monitor.Disk.threshold.LOWER=90
186 + Monitor.Disk.threshold.UPPER=95
187 +
188 + # timings of the alerts (in seconds)
189 + Monitor.Disk.alertTimeout.NOTICE=60
190 + Monitor.Disk.alertTimeout.WARNING=900
191 + Monitor.Disk.alertTimeout.CAUTION=1800
192 + Monitor.Disk.alertTimeout.CRITICAL=3600
193 +
194 +
195 + ## Services monitor configuration
196 + # threshold values
197 + #
198 + # THE SERVICES MONITOR USES A HACK
199 + # WHEREBY IT USES THE SERVICE STATUS
200 + # AS THE THRESHOLD LEVEL.  THIS SHOULD
201 + # BE LOOKED AT!
202 + #
203 + # note: if the UPPER threshold is broken,
204 + # the alertTimeout values are halved.
205 + # This is to escalate the alert quicker.
206 + #Monitor.Services.threshold.LOWER=120
207 + #Monitor.Services.threshold.LOWER=300
208 +
209 + # timings of the alerts (in seconds)
210 + Monitor.Services.alertTimeout.NOTICE=60
211 + Monitor.Services.alertTimeout.WARNING=900
212 + Monitor.Services.alertTimeout.CAUTION=1800
213 + Monitor.Services.alertTimeout.CRITICAL=3600
214 +
215 + # Make sure we shut up eventually
216 + Monitor.Services.reachFINALcount=5
217 +
218 +
219 + ## Heartbeat monitor configuration
220 + # threshold values
221 + #
222 + # note: if the UPPER threshold is broken,
223 + # the alertTimeout values are halved.
224 + # This is to escalate the alert quicker.
225 + Monitor.Heartbeat.checkPeriod=50
226 + # these are values in seconds from when the heartbeat
227 + # was *expected* to arrive (ie. last + hearbeat period)
228 + Monitor.Heartbeat.threshold.LOWER=120
229 + Monitor.Heartbeat.threshold.UPPER=300
230 +
231 + # timings of the alerts (in seconds)
232 + Monitor.Heartbeat.alertTimeout.NOTICE=60
233 + Monitor.Heartbeat.alertTimeout.WARNING=900
234 + Monitor.Heartbeat.alertTimeout.CAUTION=1800
235 + Monitor.Heartbeat.alertTimeout.CRITICAL=3600
236 +
237 + # this means it will reach a FINAL level,
238 + # and thus the host will be removed from the monitor list,
239 + # if the highest level alert is reached and occours this
240 + # number of times.
241 + #
242 + # int this setup, that means 5 CRITICAL alerts would occour
243 + # on a Heartbeat before reaching FINAL.
244 + # If this value is wrong or not present, FINAL is never reached
245 + #
246 + Monitor.Heartbeat.reachFINALcount=5
247 +
248   ############################################################
249   #### Alerter Configuration
250   ############################################################
251 + # The following var's are understood by ALL alerters for messages
252 + #
253 + # %level%               - the alert level (eg, WARNING)
254 + # %threshold%           - the threshold broken (eg, LOWER)
255 + # %source%              - the source of the alert (eg, raptor.ukc.ac.uk)
256 + # %value%               - the value reached (eg, 95)
257 + # %thresholdValue%      - the value of the threshold broken (eg, 90)
258 + # %attributeName%       - the attribute that has caused the alert (eg, CPU User)
259 + # %timeTillNextAlert%   - the time the next alert will be sent out
260 + # %timeSinceFirstAlert% - the time elapsed since the first alert for this problem
261 + # %timeOfFirstAlert%    - the time the first alert was sent
262 + #
263  
264   # alerters to run
265 < Alerter.PluginsPackage=uk.ac.ukc.iscream.client.alerters
266 < Alerter.Plugins=EMail;IRC;
265 > Alerter.PluginsPackage=uk.org.iscream.client.alerters
266 > #Alerter.Plugins=EMail;IRC;WebFeeder;
267 > Alerter.Plugins=IRC;WebFeeder;
268 > #Alerter.Plugins=WebFeeder;
269 > #Alerter.Plugins=
270  
271   # EMail alerter configuration
272 < Alerter.EMail.level = CAUTION
272 > Alerter.EMail.level = WARNING
273   Alerter.EMail.destList = dev@i-scream.org.uk
274   Alerter.EMail.sender = dev@i-scream.org.uk
275   Alerter.EMail.smtpServer = mercury.ukc.ac.uk
276   Alerter.EMail.subject = i-scream alert: %level% alert on %source% for %attributeName%
277 < Alerter.EMail.message = The i-scream distributed central monitoring system has\nraised a %level% alert for the host %source%.\n\nThe value for %attributeName% of %value% has exceeded the\n%threshold% threshold value of %thresholdValue%.\n\nThe next alert (should one occur) will be sent in %timeTillNextAlert%.
277 > Alerter.EMail.message = The i-scream distributed central monitoring system has\nraised a %level% alert for the host %source%.\n\nThe value for %attributeName% of %value% has exceeded the\n%threshold% threshold value of %thresholdValue%.\n\nThis alert was originally raised at %timeOfFirstAlert%,\nwhich was %timeSinceFirstAlert% ago.\n\nThe next alert (should one occur) will be sent in %timeTillNextAlert%.
278  
279 +
280   # IRC alerter configuration
281   Alerter.IRC.level = OK
282   Alerter.IRC.IRCServer = killigrew.ukc.ac.uk
# Line 170 | Line 299 | Alerter.IRC.timeSinceLastAlertCommand = time since las
299   Alerter.IRC.versionCommand = version
300   Alerter.IRC.helpCommand = help
301   Alerter.IRC.rejectMessage = sorry, I don't understand your request
302 +
303 + ############################################################
304 + #### WebFeeder Configuration
305 + ############################################################
306 +
307 + # Define these (one or both_ to turn on the WebFeeder's,
308 + # comment it to turn them off
309 + WebFeeder.latestActive = true
310 + WebFeeder.alertActive = true
311 +
312 + # Check period in seconds (for cleaning stale/old alerts)
313 + WebFeeder.checkPeriod = 120
314 +
315 + # Delete alerts older than this, in seconds.
316 + # Files are only check every WebFeeder.checkPeriod seconds.
317 + WebFeeder.alertDeleteOlderThan = 300
318 +
319 + # Root Path
320 + WebFeeder.rootPath = /usr/local/proj/co600_10/webroot
321 +
322 + # Latest Data
323 + WebFeeder.latestSubDir = latest
324 + WebFeeder.latestFileName = latest_data
325 +
326 + # Alert Data
327 + WebFeeder.alertSubDir = alert
328 + WebFeeder.alertFileName = alert_data
329  
330   ############################################################
331  

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines