ViewVC Help
View File | Revision Log | Show Annotations | Revision Graph | Root Listing
root/i-scream/projects/cms/source/server/build/etc/system.conf
(Generate patch)

Comparing projects/cms/source/server/build/etc/system.conf (file contents):
Revision 1.45 by tdb, Thu Mar 22 01:57:14 2001 UTC vs.
Revision 1.47 by tdb, Thu Mar 22 02:18:05 2001 UTC

# Line 121 | Line 121 | Host.serviceChecksPackage=uk.org.iscream.filter.plugin
121   #### Monitor Configuration
122   ############################################################
123  
124 < # the monitors to run
124 > ## The monitors to run
125   Monitor.PluginsPackage=uk.org.iscream.client.monitors
126 < Monitor.Plugins=CPU;Load;Process;Disk;Memory;Swap;Services;Heartbeat;WebFeeder;
127 < #Monitor.Plugins=CPU;WebFeeder;
128 < #Monitor.Plugins=
126 > Monitor.Plugins=CPU;Load;Process;Disk;Memory;Swap;Services;Heartbeat;Queue;WebFeeder;
127  
128 + ## Default alert timeouts
129 + # these can be override on a per-monitor basis
130 + # timings of the alerts (in seconds)
131 + Monitor.alertTimeout.NOTICE=60
132 + Monitor.alertTimeout.WARNING=900
133 + Monitor.alertTimeout.CAUTION=1800
134 + Monitor.alertTimeout.CRITICAL=3600
135  
136 < ## CPU monitor configuration
132 < # threshold values
136 > ## Threshold values
137   #
138   # note: if the UPPER threshold is broken,
139   # the alertTimeout values are halved.
140   # This is to escalate the alert quicker.
141 + #
142 +
143 + # CPU monitor threshold values
144   Monitor.CPU.threshold.LOWER=90
145   Monitor.CPU.threshold.UPPER=99
146  
140 # timings of the alerts (in seconds)
141 Monitor.CPU.alertTimeout.NOTICE=60
142 Monitor.CPU.alertTimeout.WARNING=900
143 Monitor.CPU.alertTimeout.CAUTION=1800
144 Monitor.CPU.alertTimeout.CRITICAL=3600
147  
148 <
147 < ## Load monitor configuration
148 < # threshold values
149 < #
150 < # note: if the UPPER threshold is broken,
151 < # the alertTimeout values are halved.
152 < # This is to escalate the alert quicker.
148 > # Load monitor threshold values
149   Monitor.Load.threshold.LOWER=10.0
150   Monitor.Load.threshold.UPPER=20.0
151  
156 # timings of the alerts (in seconds)
157 Monitor.Load.alertTimeout.NOTICE=60
158 Monitor.Load.alertTimeout.WARNING=900
159 Monitor.Load.alertTimeout.CAUTION=1800
160 Monitor.Load.alertTimeout.CRITICAL=3600
152  
153 <
163 < ## Process Count monitor configuration
164 < # threshold values
165 < #
166 < # note: if the UPPER threshold is broken,
167 < # the alertTimeout values are halved.
168 < # This is to escalate the alert quicker.
153 > # Process Count threshold values
154   Monitor.Process.threshold.LOWER=1000
155   Monitor.Process.threshold.UPPER=1500
156  
172 # timings of the alerts (in seconds)
173 Monitor.Process.alertTimeout.NOTICE=60
174 Monitor.Process.alertTimeout.WARNING=900
175 Monitor.Process.alertTimeout.CAUTION=1800
176 Monitor.Process.alertTimeout.CRITICAL=3600
157  
158 <
179 < ## Memory monitor configuration
180 < # threshold values
181 < #
182 < # note: if the UPPER threshold is broken,
183 < # the alertTimeout values are halved.
184 < # This is to escalate the alert quicker.
158 > # Memory monitor threshold values
159   Monitor.Memory.threshold.LOWER=80
160   Monitor.Memory.threshold.UPPER=90
161  
188 # timings of the alerts (in seconds)
189 Monitor.Memory.alertTimeout.NOTICE=60
190 Monitor.Memory.alertTimeout.WARNING=900
191 Monitor.Memory.alertTimeout.CAUTION=1800
192 Monitor.Memory.alertTimeout.CRITICAL=3600
162  
163 <
195 < ## Swap monitor configuration
196 < # threshold values
197 < #
198 < # note: if the UPPER threshold is broken,
199 < # the alertTimeout values are halved.
200 < # This is to escalate the alert quicker.
163 > # Swap monitor threshold values
164   Monitor.Swap.threshold.LOWER=80
165   Monitor.Swap.threshold.UPPER=90
166  
204 # timings of the alerts (in seconds)
205 Monitor.Swap.alertTimeout.NOTICE=60
206 Monitor.Swap.alertTimeout.WARNING=900
207 Monitor.Swap.alertTimeout.CAUTION=1800
208 Monitor.Swap.alertTimeout.CRITICAL=3600
167  
168 <
211 < ## Disk monitor configuration
212 < # threshold values
213 < #
214 < # note: if the UPPER threshold is broken,
215 < # the alertTimeout values are halved.
216 < # This is to escalate the alert quicker.
168 > # Disk monitor threshold values
169   Monitor.Disk.threshold.LOWER=90
170   Monitor.Disk.threshold.UPPER=95
171 + # Thresholds given are PERCENTAGE or VALUE
172 + # where PERCENTAGE is a percentage of disk in use
173 + # and VALUE is an absolute value of space free
174 + Monitor.Disk.thresholdMeasure=PERCENTAGE
175  
220 # timings of the alerts (in seconds)
221 Monitor.Disk.alertTimeout.NOTICE=60
222 Monitor.Disk.alertTimeout.WARNING=900
223 Monitor.Disk.alertTimeout.CAUTION=1800
224 Monitor.Disk.alertTimeout.CRITICAL=3600
176  
177 + # Disk monitor threshold values
178 + Monitor.Queue.threshold.LOWER=90
179 + Monitor.Queue.threshold.UPPER=95
180 + # Thresholds given are PERCENTAGE or VALUE
181 + # where PERCENTAGE is a percentage of disk in use
182 + # and VALUE is an absolute value of space free
183 + Monitor.Queue.thresholdMeasure=PERCENTAGE
184  
185 < ## Services monitor configuration
186 < # threshold values
185 >
186 > # Services monitor threshold values
187   #
188   # THE SERVICES MONITOR USES A HACK
189   # WHEREBY IT USES THE SERVICE STATUS
190   # AS THE THRESHOLD LEVEL.  THIS SHOULD
191   # BE LOOKED AT!
192   #
193 < # note: if the UPPER threshold is broken,
194 < # the alertTimeout values are halved.
237 < # This is to escalate the alert quicker.
238 < #Monitor.Services.threshold.LOWER=120
239 < #Monitor.Services.threshold.LOWER=300
240 <
241 < # timings of the alerts (in seconds)
242 < Monitor.Services.alertTimeout.NOTICE=60
243 < Monitor.Services.alertTimeout.WARNING=900
244 < Monitor.Services.alertTimeout.CAUTION=1800
245 < Monitor.Services.alertTimeout.CRITICAL=3600
246 <
247 < # Make sure we shut up eventually
193 > # how many times we should be at the highest level before
194 > # we go to a FINAL alert
195   Monitor.Services.reachFINALcount=5
196  
197  
198 < ## Heartbeat monitor configuration
252 < # threshold values
253 < #
254 < # note: if the UPPER threshold is broken,
255 < # the alertTimeout values are halved.
256 < # This is to escalate the alert quicker.
257 < Monitor.Heartbeat.checkPeriod=50
198 > # Heartbeat threshold values
199   # these are values in seconds from when the heartbeat
200   # was *expected* to arrive (ie. last + hearbeat period)
201   Monitor.Heartbeat.threshold.LOWER=120
202   Monitor.Heartbeat.threshold.UPPER=300
203 + # this is how often we will run a "check" of heartbeats
204 + Monitor.Heartbeat.checkPeriod=30
205 + # how many times we should be at the highest level before
206 + # we go to a FINAL alert
207 + Monitor.Heartbeat.reachFINALcount=5
208  
263 # timings of the alerts (in seconds)
264 Monitor.Heartbeat.alertTimeout.NOTICE=60
265 Monitor.Heartbeat.alertTimeout.WARNING=900
266 Monitor.Heartbeat.alertTimeout.CAUTION=1800
267 Monitor.Heartbeat.alertTimeout.CRITICAL=3600
209  
269 # this means it will reach a FINAL level,
270 # and thus the host will be removed from the monitor list,
271 # if the highest level alert is reached and occours this
272 # number of times.
273 #
274 # int this setup, that means 5 CRITICAL alerts would occour
275 # on a Heartbeat before reaching FINAL.
276 # If this value is wrong or not present, FINAL is never reached
277 #
278 Monitor.Heartbeat.reachFINALcount=5
210  
211   ############################################################
212   #### Alerter Configuration
# Line 295 | Line 226 | Monitor.Heartbeat.reachFINALcount=5
226  
227   # alerters to run
228   Alerter.PluginsPackage=uk.org.iscream.client.alerters
229 < #Alerter.Plugins=EMail;IRC;WebFeeder;
299 < Alerter.Plugins=IRC;WebFeeder;
300 < #Alerter.Plugins=WebFeeder;
301 < #Alerter.Plugins=
229 > Alerter.Plugins=EMail;IRC;WebFeeder;
230  
231 +
232   # EMail alerter configuration
233   Alerter.EMail.level = WARNING
234   Alerter.EMail.destList = dev@i-scream.org.uk
# Line 332 | Line 261 | Alerter.IRC.versionCommand = version
261   Alerter.IRC.helpCommand = help
262   Alerter.IRC.rejectMessage = sorry, I don't understand your request
263  
264 +
265 +
266   ############################################################
267   #### WebFeeder Configuration
268   ############################################################
# Line 362 | Line 293 | WebFeeder.latestFileName = latest_data
293   WebFeeder.alertSubDir = alert
294   WebFeeder.alertFileName = alert_data
295  
365 ############################################################
296  
297 + ############################################################

Diff Legend

Removed lines
+ Added lines
< Changed lines
> Changed lines